§ 10-3-2 — Amendments to National Electrical Code
Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Code of Ordinances § 10-3-2
Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/2277e261-e5d4-4ccf-9b37-365039855a94
10-3-2. - Amendments to National Electrical Code.
A. Article 210.8(A)(7) shall be deleted and replaced with the following: Sinks located in areas other than kitchens where receptacles are installed within six (6) feet of the outside edge of the sink. B. Article 210.8(A)(10) shall be deleted. C. Article 210.8(D) shall be deleted. D. Article 210.12 shall be amended by the addition of the following language: Definition. Arc-Fault Circuit-Interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected. Dwelling Unit Bedrooms. All one hundred twenty (120)-volt, single phase, fifteen (15)-ampere and twenty (20)-ampere branch circuits supplying outlets installed in dwelling unit bedrooms shall be protected by a listed arc-fault circuit interrupter, combination type installed to provide protection of the branch circuit. Compliance with Article 210.12 Arc-Fault Circuit- Interrupter Protection. Article 210.12 shall apply in full. Exception. In dwelling units Arc-Fault Circuit- Interrupter Protection shall only apply to all branch circuits and outlets supplying bedrooms. All other location in dwelling units are exempt from the requirements of Article 210.12. E. Article 210.52(E)(3) shall be deleted and replaced with the following: Balconies, decks, and porches having an overall area of twenty (20) square feet or more that are accessible from inside the dwelling unit shall have at least one (1) receptacle outlet installed within the perimeter of the balcony, deck, or porch. The receptacle shall not be located more than six and one half (6½) feet above the balcony, deck, or porch surface. F. Article 334.10(A) shall be amended by the addition of the following language: 3. Where the height of a crawl space does not exceed four and one half (4½) feet it shall be permissible to secure NM cables, that run at angles with joist, to the bottom edge of joist. NM cables that run within seven (7) feet of crawl space access shall comply with article 320.23. G. Article 550.32(B) shall be amended by the addition of the following language: Compliance with article 550.32(B) shall limit installation of a service on a manufactured home to those homes manufactured after January 1, 1992. H. Article 675.8(B) shall be amended by the addition of the following language: Compliance with article 675.8(B) will include the additional requirement that a disconnecting means always be provided at the point of service from the utility no matter where the disconnecting means for the machine is located. I. Poles used as lighting standards that are forty (40) feet or less in nominal height and that support no more than four (4) luminaires operating at a nominal voltage of three hundred (300) volts or less, shall not be considered to constitute a structure as that term is defined by the national electrical code (NEC). The disconnecting means shall not be mounted to the pole. The disconnecting means may be permitted elsewhere in accordance with NEC, article 225.32, exception 3. SEC special purpose fuseable connectors (model SEC 1791-DF or model SEC 1791-SF) or equivalent shall be installed in a listed handhole (underground) enclosure. The enclosure shall be appropriately grounded and bonded per the requirements of the NEC applicable to article 230-Services. Overcurrent protection shall be provided by a (fast-acting - minimum - 100K RMS amps 600 VAC) rated fuse. Wiring within the pole for the luminaires shall be protected by supplementary overcurrent device (time-delay - minimum - 10K RMS amps 600 VAC) in breakaway fuse holder accessible from the hand hole. Any poles supporting or incorporating utilization equipment or exceeding the prescribed number of luminaires, or in excess of forty (40) feet, shall be considered structures, and an appropriate service disconnecting means shall be required per the NEC. All luminaire-supporting poles shall be appropriately grounded and bonded per the NEC.
(Ord. 17-1754, 11-28-2017, eff. 1-1-2018)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.