For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11-2D-6 — Standards in the traditional neighborhood residential district (TN-R)

Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Unified Development Code, art. D, § 11-2D-6

Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/c0fddc76-23d3-40c4-bb40-2666cf3bed59

11-2D-6. - Standards in the traditional neighborhood residential district (TN-R).

The standards for development in the traditional neighborhood residential district are set forth in this section as follows: A. Dimensional standards. TABLE 11-2D-6 DIMENSIONAL STANDARDS IN THE TN-R DISTRICT Dimensional Standards | TN-R Minimum density (dwelling units per acre) | 6 net Minimum front setback: For alley accessed properties 1 (in feet) | 8 For street accessed properties 1 (in feet) | 20 to garage 8 to living area Minimum rear setback: For alley accessed properties 1 (in feet) | 5 For street accessed properties 1 (in feet) | 12 Minimum side setback (in feet): Property lines adjoining unattached walls | 3 Property lines adjoining attached walls 2 | 0 Minimum side street setback 1 (in feet): Alley | 5 Local street | 5 Collector (for alley accessed properties) 3, 4 | 11: 6 parkway with class II trees and 5-foot sidewalk Collector (for street accessed properties) 3, 5 | 18: 6 parkway with class II trees and 5-foot sidewalk Street landscape buffer 1 (in feet): Alley | 5 Local 3 | 8 parkway with class II trees Collector (for alley accessed properties) 3, 4 | 13: 8 parkway with class II trees and 5-foot sidewalk Collector (for street accessed properties) 3, 5 | 20: 8 parkway with class II trees and 5-foot sidewalk Arterial | 25 Entryway corridor | 35 Interstate | 50 Maximum height to eave providing roof access (in feet) | 30 Maximum building height (in feet) | 40 Notes: 1 Measured from back of sidewalk and/or alley right-of-way as applicable. 2 On any given property, there shall be no more than 2 property lines that have 0-foot setbacks. 3 Measured from back of curb. 4 These are standards for properties where the front yard of the property adjoins the street landscape buffer and the units take access from an alley. 5 These are standards for properties where the rear or side yard of the property adjoins the street landscape buffer. 6 A reduction to the width of the buffer may be requested as set forth in subsection 11-3B-7.C.1.c of this title. B. Minimum property size. Each building site shall be of sufficient size to meet the minimum setbacks as established in this section. C. Housing unit allocation. In the TN-R district, a minimum of two (2) housing types, including, but not limited to, single-family dwellings with attached garages, single-family dwellings with detached garages, single-family dwellings with alley loaded garages, single-family dwellings with alley loaded garages facing a mew, townhouses, and multifamily dwellings, shall be required on any subdivision submittal or planned unit development application. D. Drainage. 1. In no case shall a development propose less than a five-foot setback adjacent to a property that is not part of the development application. 2. Properties shall provide adequate area to maintain drainage on the site. E. Options for street sections in the TN-R district. 1. For alley accessed properties, the following options shall apply: a. Standard ACHD street sections. b. Fire lane chicane option as shown in figure 11-2D-6.E of this section. FIGURE 11-2D-6E [image omitted; see the official code] 2. Although street accessed properties are allowed in this district, it is anticipated that only properties on the perimeter of a TN-R development would be street accessed. The applicant shall demonstrate that the design meets the purpose statement of the TN-R district. Standard ACHD street sections shall apply. 3. Block lengths shall meet the standards as set forth in subsection 11-6C-3.F.2 of this title. F. Lighting. In addition to the standards as set forth in section 11-3A-11 of this title, the following standards shall apply within the TN-R district. All dwelling units shall have a minimum of two (2) lights at the front of the unit. All dwelling units on alley accessed properties shall have a minimum of two (2) lights along the alley. All lighting required in this section shall prevent uplighting and shall be on a photocell that activates the lighting at dusk and turns it off at dawn.

(Ord. 05-1170, 8-30-2005, eff. 9-15-2005; Ord. 06-1241, 7-5-2006, eff. 7-15-2006; Ord. 12-1514, 5-16-2012, eff. 5-21-2012; Ord. 14-1623, 9-2-2014; Ord. 16-1717, 1-3-2017)

Ask a question about Meridian law

Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.