§ 11-3A-19 — Structure and site design standards
Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Unified Development Code, art. A, § 11-3A-19
Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/4f8d6800-f81f-4651-ae47-d6702ef819fa
11-3A-19. - Structure and site design standards.
A. Purpose. 1. Encourage site design that provides an interconnected network of walkways, pathways, streets, and/or drive aisles that combined promote pedestrian and vehicular mobility within the development and connect to adjacent developments. 2. To facilitate the efficient movement of traffic into, out of, and through a site, protect pedestrian and bicycle users, establish an aesthetically consistent street presence and limit the visual impacts of large parking areas on a site. B. Minimum standards. The following minimum standards shall apply in addition to the detailed guidelines as set forth in the "City of Meridian Architectural Standards Manual." 1. Architectural character. Buildings shall be designed in accord with the "City of Meridian Architectural Standards Manual." 2. Site design. a. Extend or improve streets, drive aisles, cross access easements or similar vehicular and pedestrian connections provided from adjacent properties. b. For lots with frontage on a public street, a minimum of thirty (30) percent of the buildable frontage of the property shall be occupied by building facades and/or public space. Within mixed use areas, and for large multi-building developments, buildings may be placed away from roadways if a minimum of forty (40) percent of the buildable frontage is occupied by building facades and/or public space. 3. Parking lots. a. For properties greater than two (2) acres in size, no more than fifty (50) percent of the total off street parking area for the site shall be located between building facades and abutting streets. This requirement may be reduced or waived at the determination of the director in industrial districts where there is an operational need to separate a secure outdoor storage yard from the parking area. b. For properties two (2) acres or less in size, a maximum of a single drive aisle with parking on one (1) or both sides shall be allowed between the building facades and abutting streets. All other off-street parking areas shall not be located between the building facades and abutting streets. c. The design and layout of internal site parking shall avoid long straight unbroken parking aisles, provide crossing drive aisles for internal circulation at approximately one hundred fifty-foot intervals, or provide parking that is perpendicular to the building. d. Where on street parking is provided or where vehicle circulation is directed in front of building entries, integrate traffic calming strategies and techniques, such as landscape islands, bulb outs, and/or detailed crosswalks, to increase safety and enhance the development character. e. In the traditional neighborhood districts parking shall be primarily located behind or to the side of buildings and public spaces, away from block corners and roadways. f. When parking and drive-throughs cannot comply with the standards above, they shall be screened by berms, landscaping, walls, architectural elements, or a combination of these elements to produce an appropriate buffer adjacent to public spaces and roadways. 4. Pedestrian walkways. a. A continuous internal pedestrian walkway that is a minimum of five (5) feet in width shall be provided from the perimeter sidewalk to the main building entrance(s) for nonresidential uses. The walkway width shall be maintained clear of any obstructions, such as vehicles, outdoor sale displays, vending machines, or temporary structures. b. The internal pedestrian walkway shall be distinguished from the vehicular driving surfaces through the use of pavers, colored or scored concrete, or bricks. c. Unobstructed walkways at least five (5) feet in width shall be provided for any aisle length that is greater than one hundred fifty (150) parking spaces or two hundred (200) feet away from the primary building entrance(s). d. The walkways shall have weather protection (including, but not limited to, an awning or arcade) within twenty (20) feet of all customer entrances. C. Alternative compliance. If: 1. The location of existing buildings or structures prevents conformance with the standards of this section, or 2. Strict adherence to such standards would create inconsistency in the design objectives of the proposed development, the Director may consider an alternative design proposal through the alternative compliance provisions as set forth in Section 11-5B-5 of this Title. The Director may approve, or recommend approval of, such an alternative compliance proposal when the overall design, as proposed by the applicant, meets or exceeds the intent and the requirements of this section and is not detrimental to public health, safety, and welfare.
(Ord. 16-1717, 1-3-2017; Ord. No. 22-2001, § 7, 11-1-2022)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.