§ 3-8-4 — Storage of fireworks—Specific standards and regulations
Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Code of Ordinances § 3-8-4
Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/6f9531de-0752-44dc-965e-8f509f3432c7
3-8-4. - Storage of fireworks—Specific standards and regulations.
In addition to the applicable provisions of the version of the International Fire Code currently in effect, the following provisions shall apply to the storage of fireworks. Where the provisions of the International Fire Code and the provisions of this section conflict, the provisions of this section shall apply. A. No storage without permit. No person, without having a valid nonaerial common fireworks permit or public fireworks display permit issued pursuant to this chapter, shall store nonaerial common fireworks in any manner or for any use or purpose. B. One storage unit per parcel. Only one (1) short-term storage container in addition to the temporary fireworks stand shall be allowed per parcel. C. Set up and removal. Short-term storage containers used during the summer sales period shall not be placed at the sales site before June 15 and shall be removed by 12:00 p.m. (noon) on July 6. Short-term storage containers used during the winter sales period shall not be placed at the sales site before December 15 and shall be removed by 12:00 p.m. (noon) on January 3. D. No storage in residential districts. The storage of fireworks shall be prohibited in residential districts as such districts are defined by the Meridian Unified Development Code. E. No storage in right-of-way. Short-term storage containers shall not be placed or erected within the public right-of-way. F. No storage in permanent structures. No person shall construct, cause to be constructed, or use any permanent structure for the storage of nonaerial common fireworks. G. Secure storage. Stored fireworks shall be secured in a manner that denies any and all access to such fireworks by persons other than the operator. H. Exit. No operator shall cause or allow any exit from a short-term storage container to be obstructed, unopenable, inaccessible, or malfunctioning. I. Storage requirements. Operators shall comply with, and, as applicable, shall ensure their patrons' and the public's compliance with, each and all of the following provisions regarding short-term storage containers: 1. Any and all short-term storage containers shall comply with all applicable provisions of this Code, including, but not limited to, the Unified Development Code, the building code, the fire code, and the electrical code. The operator shall obtain any and all required permits. 2. No short-term storage container shall have a floor area in excess of three hundred twenty (320) square feet. 3. Operators shall locate and maintain any short-term storage container in compliance with the following minimum separation distances: Exposure | Minimum Separation Distance Roadway or sidewalk | 20 feet Building | 20 feet Fireworks stand | 100 feet Vehicle fuel dispensing | 100 feet Propane cylinder exchange station | 100 feet Flammable gas or flammable liquefied gas bulk aboveground storage or dispensing | 300 feet Flammable and combustible liquid or gas aboveground tank storage | 300 feet Vehicle access and parking area | 20 feet Combustible storage | 20 feet Generator | 20 feet Short-term storage container | 20 feet Weeds or vegetation | 20 feet Trash, rubbish, debris, waste receptacle | 20 feet Cooking equipment | 25 feet Any fire hazard | 20 feet 4. Any and all short-term storage containers shall be located at least one hundred feet (100) from any flammable liquid dispensing device or installation. 5. Any and all short-term storage containers shall contain a minimum of one (1) pressurized water fire extinguisher with a minimum rating of 2A, which fire extinguisher shall be located in an accessible and visible location within forty-eight (48) inches of the access door. If such container has more than one (1) access door, a fire extinguisher shall be located in an accessible and visible location within forty-eight (48) inches of each and every access door. 6. No person shall sleep in any short-term storage container at any time. 7. At least one (1) sign reading, "Fireworks - No Smoking or Vaping Within 25 Feet" in letters at least four inches (4") high on a contrasting background shall be posted on each and every interior wall and each and every exterior wall or side of any and all short-term storage containers. Such signs shall be maintained in a legible condition at all times. 8. At least one (1) sign reading, "No Fireworks to Be Discharged Within 100 Feet" in letters at least four inches (4") high on a contrasting background shall be posted on each and every exterior wall or side of any and all short-term storage containers. Such signs shall be maintained in a legible condition at all times. J. Storage in temporary fireworks stand. Where a temporary fireworks stand is used as a short-term storage facility, such temporary fireworks stand shall comply with all applicable provisions of this section in addition to any and all other applicable provisions of this chapter. Where such temporary fireworks stand is constructed with hard sides, it shall be effectively secured by a working lock or locks at all times and at all access points, except during active loading and/or unloading. Where such temporary fireworks stand is constructed with canvas or other soft material sides, shall be effectively secured by a person who shall remain awake, alert, and on site at all times and who shall prevent any and all access to fireworks or other merchandise stored therein. K. Storage in trailer or vehicle. Where a truck trailer or a vehicle is used as a short-term storage container, such truck trailer or vehicle: 1. Shall comply with all applicable provisions of this section in addition to any and all other applicable provisions of this chapter. 2. Shall be effectively secured by a working lock or locks at all times and at all access points, except during active loading and/or unloading. 3. Shall be marked in accordance with United States Department of Transportation requirements. L. Storage of dangerous fireworks. Storage of dangerous fireworks shall be unlawful unless specifically authorized by a valid public fireworks display permit issued pursuant to this chapter. Dangerous fireworks shall be stored in accordance with any and all applicable provisions of this chapter governing short-term storage containers and all applicable provisions of the International Fire Code, except that no person shall store dangerous fireworks: 1. In a temporary fireworks stand. 2. In any soft sided structure, including, but not limited to, a tent. 3. In any place or in any manner allowing access to such fireworks by anyone other than the permittee. 4. In any place or in any manner which endangers the health, safety, and/or welfare of persons and/or property.
(Ord. No. 23-2038, § 6, 10-17-2023)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.
