§ 9-2-3 — Wastewater discharge permit
Code of Ordinances of the City of Meridian, Idaho (Supp. No. 14: codified through Ordinance No. 26-2129, enacted July 7, 2026) · Meridian Code of Ordinances § 9-2-3
Corpus is an independent public-information project, not the official City of Meridian website. Stable reference: corpuslaw.us/code/92a76e53-1378-403e-809d-bc1b8abc4104
9-2-3. - Wastewater discharge permit.
No significant industrial user shall discharge wastewater into the POTW without first obtaining a wastewater discharge permit from the Superintendent or designee. Any violation of the terms and conditions of the discharge permit shall be deemed a violation of this chapter and subjects the wastewater discharge permittee to the sanctions set forth in this chapter. Obtaining a wastewater discharge permit does not relieve a permittee of its obligations to comply with all federal and state pretreatment standards or requirements or with any other requirements of federal, state, and local law. The Superintendent or designee may require other users, including liquid waste haulers, to obtain wastewater discharge permits to carry out the purposes of this chapter. 9-2-3-1. Wastewater discharge permitting; existing SIU. Any SIU that was discharging wastewater into the POTW prior to the effective date hereof and that wishes to continue such discharges in the future, shall, within sixty (60) days after notification by the Superintendent or designee submit a permit application to the City of Meridian in accordance with section 9-2-3-3 of this chapter and shall not cause or allow discharges to the POTW to continue after one hundred eighty (180) days of the effective date hereof except in accordance with a wastewater discharge permit issued by the Superintendent or designee. 9-2-3-2. Wastewater discharge permitting; new source and new user. At least ninety (90) days prior to the anticipated startup, any new source, which is a source that becomes a user subsequent to the proposal of an applicable categorical pretreatment standard that is later promulgated, and any new user considered by the City of Meridian to fit the definition of SIU shall apply for a wastewater discharge permit and will be required to submit to the city at least the information listed in subsections 9-2-3-3A through E of this chapter. A new source or new user cannot discharge without first receiving a wastewater discharge permit from the City of Meridian. New sources and new users shall also be required to include in their application information on the method of pretreatment they intend to use to meet applicable pretreatment standards. New sources and new users shall give estimates of the information requested in subsections 9-2-3-3D and E of this chapter. 9-2-3-3. Permit application contents. All users required to obtain a wastewater discharge permit must submit, at a minimum, the following information. The Superintendent or designee shall approve a form to be used as a permit application. Categorical users submitting the following information shall have complied with 40 CFR 403.12(b): A. Identifying information. The user shall submit the name and address of the facility including the name of the operator and owners. B. Permits. The user shall submit a list of all environmental control permits held by or for the facility. C. Description of operations. The user shall submit a city DDF (data disclosure form) that describes the operational processes. D. Flow measurement. 1. Categorical user. The user shall submit information showing the measured average daily and maximum daily flow, in gallons per day, to the POTW from each of the following. a. Regulated or manufacturing process streams; and b. Other streams as necessary to allow use of the combined waste stream formula (40 CFR 403.6(e)). 2. Noncategorical user. The user shall submit information showing the measured average daily and maximum daily flow, in gallons per day, to the POTW from each of the following: a. Total process flow, wastewater treatment plant flow, total plant flow or individual manufacturing process flow as required by the Superintendent or designee. The City of Meridian may allow for verifiable estimates of these flows where consideration is justified by cost or feasibility. E. Measurements of pollutants. 1. Categorical user. a. The user shall identify the applicable pretreatment standards for each regulated or manufacturing process. b. In addition, the user shall submit the results of sampling and analysis identifying the nature and concentration (or mass where required by the categorical pretreatment standard or as required by the city) of regulated pollutants (including standards contained in subsections 9-2-2-1 through 9-2-2-4 of this chapter, as appropriate) in the discharge from each regulated or manufacturing process. Both daily maximum and average concentration (or mass, where required) shall be reported. The sample shall be representative of daily operations and shall conform to sampling and analytical procedures outlined in section 9-2-5 of this chapter. c. The user shall take a minimum of one representative sample to compile that data necessary to comply with the requirements of this paragraph E. d. Where an alternate concentration or mass limit has been calculated in accordance with 40 CFR 403.6(e) for a categorical user, this adjusted limit along with supporting data shall be submitted as part of the application. 2. Noncategorical user. a. The user shall identify the applicable pretreatment standards for its wastewater discharge. b. In addition, the user shall submit the results of sampling and analysis identifying the nature and concentration in the discharge (or mass where required by the City of Meridian) of regulated pollutants contained in subsections 9-2-2-1 through 9-2-2-4 of this chapter, as appropriate. Both daily maximum and average concentration (or mass, where required) shall be reported. The sample shall be representative of daily operations and shall conform to sampling and analytical procedures outlined in section 9-2-5 of this chapter. c. The user shall take a minimum of one representative sample to compile that data necessary to comply with the requirements of this subsection E. d. Where the Superintendent or designee developed alternate concentration or mass limits because of dilution, this adjusted limit along with supporting data shall be submitted as part of the application. F. Certification. The user shall submit a statement, worded as specified in section 9-2-3-4 of this chapter, which has been reviewed by an authorized representative of the user, and certified by a qualified professional, indicating whether the applicable pretreatment standards are being met on a consistent basis, and, if not, whether additional operation and maintenance (O&M) and/or additional pretreatment is required for the user to meet the applicable pretreatment standards and requirements. G. Compliance schedule. If additional pretreatment and/or O&M will be required to meet the applicable pretreatment standards, the user shall submit the shortest schedule by which the user will provide such additional pretreatment and/or O&M. The user's schedule shall conform with the requirements of section 9-2-4-3 of this chapter. The completion date in this schedule shall not be later than the completion date established pursuant to section 9-2-2-9 of this chapter. 1. Where the user's categorical pretreatment standard has been modified by a removal allowance (40 CFR 403.7), the combined waste stream formula (40 CFR 403.6(e)), and/or a fundamentally different factors variance (40 CFR 403.13) at the time the user submits the report required by this subsection, the information required by subsection F of this subsection and this subsection G shall pertain to the modified limits. 2. If the categorical pretreatment standard is modified by a removal allowance (40 CFR 403.7), the combined waste stream formula (40 CFR 403.6(e)), and/or a fundamentally different factors variance (40 CFR 403.13) after the user submits the report required by paragraph F of this subsection and this paragraph G, then a report containing modified information shall be submitted by the user within sixty (60) days after the new limit is approved. H. Other information. The user shall submit any other information as may be determined necessary by the Superintendent or designee to evaluate the wastewater discharge permit application. Incomplete or inaccurate applications will not be processed and will be returned to the user for revision. 9-2-3-4. Signatory and certification requirement. All wastewater discharge permit applications and user reports must be signed by a responsible officer or manager, sole proprietor or general partner as applicable or duly authorized representative. A. For the purpose of this section, a "responsible officer or manager" means. 1. A president, vice president, secretary, or treasurer of the corporation in charge of a principal business function, or any other person who performs similar policy or decision-making functions for the corporation, or 2. The manager of one (1) or more manufacturing, production, or operating facilities, provided, the manager is authorized to make management decisions which govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations and initiating and directing other comprehensive measures to assure long term environmental compliance with environmental laws and regulations; can ensure that the necessary systems are established or actions taken to gather complete and accurate information for control mechanism requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. This authorization must be made in writing by the principal executive officer or ranking elected official and submitted to the approval authority prior to or together with the report being submitted of the user and contain the following certification statement: "I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations." B. A duly authorized representative is an individual designated by the responsible officer, manager, sole proprietor or general partner in writing. The written authorization must be submitted to the City of Meridian and also specifies either an individual or position having the responsibility of the overall operation of the facility from which the industrial discharge originates, such as the position of plant manager, operator of a well, or Well Field Superintendent, or a position of equal responsibility, or having overall responsibility for environmental matters for the company. If an authorization in this section is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, or overall responsibility for environmental matters for the company, a new authorization satisfying the requirements of this section must be submitted to the City of Meridian prior to or together with any reports to be signed by an authorized representative. 9-2-3-5. Decisions. The Superintendent or designee will evaluate the data furnished by the user and may require additional information. Within thirty (30) days of receipt of a complete wastewater discharge permit application, the Superintendent or designee will determine whether or not to issue a wastewater discharge permit. Upon a determination to issue, the permit shall be issued within thirty (30) days of full evaluation and acceptance of the data furnished. The Superintendent or designee may deny any application for a wastewater discharge permit. 9-2-3-6. Contents. Wastewater discharge permits shall include such conditions as are reasonably deemed necessary by the Superintendent or designee to prevent pass-through or interference, protect the quality of the water body receiving the treatment plant's effluent, protect worker health and safety, facilitate biosolids management and disposal, and protect against damage to the POTW. A. Wastewater discharge permits must contain the following conditions: 1. A statement that indicates wastewater discharge permit duration, which in no event shall exceed five (5) years; 2. A statement that the wastewater discharge permit is nontransferable without prior notification to and approval from the City of Meridian and provisions for furnishing the new owner or operator with a copy of the existing wastewater discharge permit; 3. Applicable pretreatment standards and requirements, including any special state requirements; 4. Self-monitoring, sampling, reporting, notification, submittal of technical reports, compliance schedules, and record keeping requirements. These requirements shall include an identification of pollutants to be monitored, sampling location, sampling frequency, and sample type based on federal, state, and local law; 5. Requirements for immediate notification to the City of Meridian where self-monitoring results indicate noncompliance; 6. Requirement to report a bypass or upset of a pretreatment facility; 7. Requirement to report immediately to the City of Meridian all discharges, including slug loadings, that could cause problems to the POTW; 8. Requirement for the SIU who reports noncompliance to repeat the sampling and analysis and submit results to the City of Meridian within thirty (30) days after becoming aware of the violation; 9. A statement of applicable civil, criminal, and administrative penalties for violation of pretreatment standards and requirements, and any applicable compliance schedule; 10. Requirements to control slug discharges, if determined by the POTW to be necessary. B. Wastewater discharge permits may contain, but need not be limited to, the following conditions: 1. Limits on the average and/or maximum rate of discharge, time of discharge, and/or requirements for flow regulation and equalization; 2. Requirements for the installation of pretreatment technology, pollution control, or construction of appropriate containment devices, designed to reduce, eliminate, or prevent the introduction of pollutants into the treatment works; 3. Requirements for the development and implementation of spill control plans or other special conditions including management practices necessary to adequately prevent any or all unwanted discharges; 4. Development and implementation of waste minimization plans to reduce the amount of pollutants discharged to the POTW; 5. The unit charge or schedule of user charges and fees for the management of the wastewater discharged to the POTW; 6. Requirements for installation and maintenance of inspection and sampling facilities and equipment; 7. A statement that compliance with the wastewater discharge permit does not relieve the permittee of responsibility for compliance with all applicable federal and state pretreatment standards, including those which become effective during the term of the wastewater discharge permit; 8. Any special agreements the Superintendent or designee chooses to continue or develop between the City of Meridian and user; 9. Other conditions as deemed appropriate by the Superintendent or designee to ensure compliance with this chapter, and state and federal laws, rules, and regulations. 9-2-3-7. Appeals. Any person, including the user, may request a hearing before the Board of Adjustment to appeal a decision by the Superintendent or designee relating to wastewater discharge permit applications within thirty (30) days of the denial or issuance of the permit and by complying in all respects with the procedures set forth in title 2, chapter 8 of this Code pertaining to the Board of Adjustment. A. Failure to submit a timely request for hearing before the Board of Adjustment shall be deemed to be a waiver of the right to appeal. B. In the request for hearing, the appealing party (hearant) must indicate the wastewater discharge permit provisions objected to, the reasons for this objection, and the alternative condition, if any, it seeks to place in the wastewater discharge permit. C. The effectiveness of the wastewater discharge permit shall not be stayed pending the appeal. D. A limited right of appeal to the City Council shall be available to a hearant who receives an adverse decision by the Board of Adjustment and complies in all respects with the procedures set forth in section 2-8-7 of this Code. E. The decision of the City Council shall be final. 9-2-3-8. Duration. Wastewater discharge permits shall be issued for a specified time period, not to exceed five (5) years. A wastewater discharge permit may be issued for a period less than five (5) years, at the discretion of the Superintendent or designee. Each wastewater discharge permit will indicate a specific date upon which it will expire. 9-2-3-9. Modification. The Superintendent or designee may modify the wastewater discharge permit for good cause including, but not limited to, the following: A. To incorporate any new or revised federal, state, or local pretreatment standards or requirements; B. To address significant alterations or additions to the user's operation, processes, or wastewater volume or character since the time of wastewater discharge permit issuance; C. A change in the POTW that requires either a temporary or permanent reduction or elimination of the authorized discharge; D. Information indicating that the permitted discharge poses a threat to the City of Meridian POTW, city personnel, or the receiving waters; E. Violation of any terms or conditions of the wastewater discharge permit; F. Misrepresentations or failure to fully disclose all relevant facts in the wastewater discharge permit application or in any required report; G. Revision of or a grant of variance from categorical pretreatment standards pursuant to 40 CFR 403.13; H. To correct typographical or other errors in the wastewater discharge permit; I. To reflect a transfer of the facility ownership or operation to a new owner or operator; J. To incorporate special conditions resulting from the issuance of a special order or an enforcement action by the City of Meridian. 9-2-3-10. Transfer. Wastewater discharge permits may be reassigned or transferred to a new owner and/or operator only if the permittee gives at least ninety (90) days' advance notice to the Superintendent or designee and the Superintendent or designee approves the wastewater discharge permit transfer. The notice to the Superintendent or designee must include a written certification by the new owner or operator which. A. States that the new owner and/or operator has no immediate intent to change the facility's operations and processes; B. Identifies the specific date on which the transfer is to occur; and C. Assumes full responsibility for complying with the existing wastewater discharge permit beginning on the date of the transfer. Failure to provide advance notice of a transfer renders the wastewater discharge permit voidable as of the date of facility transfer. Provided that the notice required above occurred and that there were no significant changes to the manufacturing operation or wastewater discharge, the new owner will be considered an existing user and will be covered by the existing limits and requirements in the previous owner's permit. 9-2-3-11. Revocation. Wastewater discharge permits may be revoked for, but not limited to, the following reasons: A. Failure to notify the Superintendent or designee of significant changes prior to the changed discharge; B. Failure to provide prior notification to the Superintendent or designee of changed conditions; C. Misrepresentation or failure to fully disclose all relevant facts in the wastewater discharge permit application; D. Falsifying self-monitoring reports; E. Tampering with monitoring equipment; F. Refusing to allow the Superintendent or designee immediate access to the facility premises and records upon request; G. Failure to meet effluent limitations; H. Failure to pay fines or fees; I. Failure to pay sewer charges; J. Failure to meet compliance schedules; K. Failure to complete a wastewater survey or the wastewater discharge permit application; L. Failure to provide advance notice of the transfer of a permitted facility; or M. If the Superintendent or designee has to invoke its emergency provision as cited in subsection 9-2-9-7 of this chapter; or N. Violation of any pretreatment standard or requirement, or any terms of the wastewater discharge permit or this chapter. Wastewater discharge permits shall be void upon cessation of operations or transfer of business ownership unless specified in subsection 9-2-3-10 of this chapter. All wastewater discharge permits issued to a particular user are void upon the issuance of a new wastewater discharge permit to that user. 9-2-3-12. Reissuance. A user who is required to have a wastewater discharge permit shall apply for wastewater discharge permit reissuance by submitting a completed wastewater discharge permit application, in accordance with this subsection 9-2-3, a minimum of sixty (60) days prior to the expiration of the user's existing wastewater discharge permit. A user whose existing discharge permit has expired and has submitted its reapplication in the time period specified herein shall be deemed to have an effective discharge permit until the Superintendent or designee issues or denies a new discharge permit. A user whose existing discharge permit has expired and who failed to submit a reapplication in the time period specified herein will be deemed to be discharging without a discharge permit in violation of this chapter.
(Ord. 08-1353, 3-18-2008, eff. 3-18-2008; Ord. 10-1469, 12-21-2010, eff. 12-27-2010)
Ask a question about Meridian law
Corpus searches the Meridian sections it holds and shows the ones that match, with their citations. Free, no sign-in.