§ 10-23-18 — Specific sign type requirements
Code of Ordinances of the City of Nampa, Idaho (Codified through Ordinance No. 4907, adopted January 5, 2026 (Supp. No. 16, Update 1)) · Nampa Code of Ordinances § 10-23-18
Corpus is an independent public-information project, not the official City of Nampa website. Stable reference: corpuslaw.us/code/41514937-b248-44a3-af61-74eff8d23948
10-23-18. - Specific sign type requirements.
Where such sign types as listed herein are permitted by this chapter, such signs shall meet the specific requirements. Specific requirements are in addition to and supplemental to all other requirements found in this chapter. A. Abandoned signs. 1. All abandoned signs shall be removed by the owner of the sign or owner of the premises within 30 days of being declared an abandoned sign. B. Awning signs. 1. No sign shall project from an awning. Awning signs shall not project above the roofline, or be located over a public right-of-way without permission from the City of Nampa. 2. Awning graphics may be painted or affixed flat to the surface of the front or sides. 3. All awning signs shall count as part of the building wall signs allowances as set forth in this chapter. 4. A commercial building permit is required for attachment or re-attachment of the awning to the structure. C. Balloons/inflatables. 1. Balloons/inflatables are permitted to be displayed, but in no case shall they be displayed for more than 90 days in any calendar year. 2. Sign permits are required to be submitted to the planning director for approval for each separate time period balloons/inflatables are displayed. D. Bus stop benches. 1. Bus stops, as designated by the regional transportation organization and authorized by the City of Nampa, may have benches with flat, poster or painted signs fastened to their back supports/rests. 2. Such signs shall not require sign permits. 3. Signs attached to bus stop benches shall be securely fastened and kept clear of graffiti. 4. Movable, temporary, prohibited or other similar type signs shall not be chained, tied, propped upon or otherwise affixed to benches. 5. Bus stop benches may be located on private residentially zoned U or GB2 zoned properties; or private properties zoned commercially or industrially even if said properties in those zones already have preexisting, freestanding signs located on them along/in the same street frontage yard area as a/the newly proposed bus bench location(s). 6. Bus stop benches with signage affixed thereto shall not be placed on properties zoned DH, DV, or DB (but bus benches without signage may be placed therein). E. Construction signs. 1. Construction signs are permitted in the BC, BF, BN, IH, IL, IP, RMH, U, and GB zoning districts only. 2. Temporary signs, such as: banners, flags, reader boards, A-frames and similar shall not be used as construction signs. 3. Display surface areas shall not be more than 50 square feet. Signs having a display area in excess of 50 square feet may be approved by the Planning Director or designated staff representative based on criteria, such as: location of signage, size of construction site/parcel, and/or special circumstances as determined. 4. All other requirements shall be as required for permanent monument and freestanding signs, such as, but not be limited to, height, material, location, etc. 5. Signs shall not be placed on a site more than 60 days prior to the start of construction, are confined to the site of construction, and need to be removed not more than 30 days after occupancy. F. Electronic changing or flashing signs (including message centers). Electronic message center and display signs that are changing or flashing types shall be allowed in all commercial (including gateway), industrial, residential professional, and university zones, and on church, school or professional office sites, except they are not permitted within the DH zone. When permitted, all signs shall comply with the following restrictions: 1. Signs that are proposed to feature electronic reader board message centers: The electronic display/message center portion of a sign shall not exceed 45 percent of the sign's overall area or 90 square feet whichever is more restrictive, and shall be made an integral part thereof. 2. The display/message of an electronic reader board sign shall remain static for at least one and one-half seconds. The display of a changing LED type billboard sign shall remain static for at least eight seconds. 3. The display of any electronic sign shall not, or shall not appear to, flash, undulate, pulse or portray explosions, fireworks, flashes of light, or blinking or chasing lights; the display shall not appear to move toward or away from the viewer, expand or contract, bounce, rotate, spin, twist, or otherwise portray movement or animation as it comes onto, is displayed on, or leaves the sign board. 4. Scrolling or traveling of a static display onto an electronic reader board sign from one direction only per display shall be allowed. A change of display must not take longer than one and one-half seconds to accomplish in the case of LED billboards and such signs shall also feature a default, static image that will be displayed in the event of malfunction or absence of advertiser paid messages. 5. The display may be of a classic nature having a dark background and copy lit in a white, amber or red shade and/or may be full color. 6. All electronic reader board signs shall have installed ambient light monitors and shall at all times allow such monitors to automatically adjust the brightness level of the electronic sign based on ambient light conditions so as to minimize and keep consistent sign brightness. Direct light sources shall not, in any event, exceed 40 watts or 60 milliamps. Full color LED billboards featuring full color display shall not exceed 7,000 nits between 7:00 a.m. to 11:00 p.m. and 2,500 nits from 11:00 p.m. to 7:00 a.m. 7. At no time shall the sign be operated at a brightness level greater than the manufacturer's recommended levels. 8. Electronic signs shall not be allowed within or in association with any dwelling or home occupation. 9. Businesses, churches or schools are allowed electronic reader board type signs provided that they comply with the standards of this section. 10. Electronic sign permit applications must also include a certification from the owner or operator of the sign stating that the sign shall at all times be operated in accordance with city codes and that the owner or operator shall provide proof of such conformance upon request of the city. 11. Electronic displays may not depict, describe, exhibit, or feature any image or message that is a moral nuisance or obscene per state code. G. Electrical signs. 1. The enclosed shell of electric signs shall be watertight, except that service holes fitted with covers shall be provided into each compartment of such signs. Electrical equipment shall be installed in accordance with the current edition of the national electrical code. Every electrical sign projecting over any street or alley or public place shall have inscribed on the surface of the sign: the name of the sign erector, the listing label, and the date of manufacture. H. Freestanding signs. All freestanding pole and monument signs shall conform to the requirements as listed herein: 1. Structure. a. A freestanding sign shall be directly supported by poles or a foundation, and shall be constructed in accordance with the sign installation details for foundation and connections. Signs exceeding 15 feet in height are required to have structural engineering calculations for the foundation, pole connections, and cabinet connections. b. Foundations for all freestanding signs must be entirely within the property line boundaries. c. Site address or range of addresses, as required, shall be included on the main freestanding sign/monument sign. When the freestanding sign/monument sign is located on a corner street or faces a street frontage in which the street is not part of the legal address, the location of the address on the sign shall be determined by the City of Nampa. Address shall be delineated with a minimum of ten inch numbers and shall not be counted as part of the allowable sign or copy area. Building mounted addresses shall be provided as required by the City of Nampa fire official. d. Freestanding pole signs shall have their poles sheathed or boxed and have material components which match the primary business building(s) finishes for the property in which the sign resides. Such coverings may include, but not be limited to: stucco, decorative metal, rock, simulated rock, and/or brick. I. Hanging signs. 1. Hanging signs shall have a vertical clearance of at least 12 feet from a sidewalk or finished grade underneath the sign, except that the bottom of a marquee or awning may be eight feet from/above the top surface of a sidewalk, or, absent a sidewalk or similar walkway, eight feet over the finished grade. 2. The display surface of a hanging sign shall not exceed six square feet. J. Interstate and highway signs. 1. Signs along interstate and primary highways shall conform to federal and state transportation department regulations as well as city standards. Notwithstanding, applicants are responsible for ensuring their compliance with any federal or state regulations as the city will not evaluate signs in accordance with those entities' rules. K. Marquee signs. 1. Marquee signs may be placed on, attached to, or constructed as part of a marquee. 2. A minimum of 12 feet of clearance is required to the sidewalk or finished grade underneath the sign cabinet, except that the bottom of a marquee or awning may be eight feet from/above the top surface of a sidewalk, or, absent a sidewalk or similar walkway, eight feet over the finished grade. 3. Such signs shall, for the purpose of determining projection, clearance, height and material, be considered a part of and shall meet the requirements for a marquee as specified in the most current adopted IBC. L. Nonconforming and conditional uses. 1. Sign structures for nonconforming uses shall not be erected, enlarged, altered or relocated, except by a conditional use permit. The application for the CUP must be accompanied by a pictorial sketch of the sign, showing the type of sign, material, lighting, setback, clearance and overhang. Prior to the approval of the CUP, the commission must make a determination that the proposed sign will not detract from the general area where it is located. M. Pole banners. 1. There is/shall be no limit to the number of pole banners which are located on private property so long as such pole banners are installed in compliance with the following: a. Pole banners are permitted on light poles, which are located on private property. Such pole banners must be attached by the appropriate brackets supplied by the manufacturer, and secured across the top and bottom; b. Pole banners shall not exceed 15 square feet; c. A minimum clearance of eight feet shall be maintained between the bottom of the pole banner and the finished grade; d. Pole banners may be permitted on city owned light poles with the expressed written consent of the City of Nampa. N. Projecting signs. 1. A minimum of 12 feet of clearance is required to the sidewalk or finished grade underneath the sign cabinet, except that the bottom of a marquee or awning may be eight feet from/above the top surface of a sidewalk, or, absent a sidewalk or similar walkway, eight feet over the finished grade. 2. The maximum projection of a projecting sign shall not exceed four feet from the building, however, that, where a projecting sign is located on a corner, the maximum projection is five feet. 3. Shall not extend beyond the top of the wall on which it is placed. 4. Only one projecting sign shall be allowed per business. A double sided projecting sign is counted as one so long as the two sign faces are part of the same structural bracing system. 5. Projecting signs shall count as part of the building wall sign allowances as set forth in this chapter. O. Reader board signs (permanent). 1. Reader boards five feet or less in height will be considered as monument type reader board signs. Reader boards greater than five feet in height will be considered as freestanding pole type reader boards. 2. Permanent monument type reader boards are permitted; however, such sign shall count against the number and square footage allowed for monument type signage. 3. Monument type reader boards shall meet all of the same requirements as specified for a monument type sign. 4. Permanent freestanding pole type reader boards are permitted; however, such sign shall count against the number and square footage allowed for freestanding type signage. 5. Freestanding pole type reader boards shall meet all of the same requirements as specified for a freestanding sign. 6. Permanent reader board type signs shall be of the nonilluminated type. P. Roof signs. Roof signs, where permitted, shall conform to the following: 1. Roof signs shall not exceed the highest point of a roof or parapet wall and shall not project farther than 18 inches from the building. 2. Roof signs shall be thoroughly secured and anchored to the frame of the building over which they are constructed and erected. Q. Searchlights, hot air or helium balloons. 1. Searchlights, hot air or helium balloons greater than ten feet in their widest dimension, or other devices determined to be similar, which do not advertise, but which are intended to provide direction or attraction are subject to the following: a. No searchlight beam shall flash against any building, cause any visual or traffic hazard, sweep an arc greater than 45 degrees from vertical and the searchlight shall be set back at least 30 feet from any public right-of-way. b. No searchlight or balloon shall be used by a new or existing business or enterprise more than four times yearly, and for no more than a maximum period of 15 consecutive days. c. Sign permits are required to be submitted to the planning director for approval each separate time period a searchlight or balloon is utilized. R. Wall signs. 1. Wall signs shall not extend above the top of the wall to which it is attached. 2. Wall signs shall be attached flat against the wall and project no farther than 18 inches from the building. S. Business complex, commercial shopping center, mall, apartment complex, and residential sign program(s). 1. Comprehensive sign program. All business parks, commercial shopping centers, special purpose centers, malls, single-family residential subdivisions and residential apartment complexes shall create a detailed sign program to govern sign type and emplacement in their respective developments. Owners/developers of such complexes shall submit to the city a sign application package describing and illustrating their sign program. The sign package shall include the following elements (as pertaining to all uses and tenants): a. Identification of the colors and materials to be used for all signage in the development. (The colors and materials shall be consistent with those used/proposed for the applicable development.) b. Details regarding the proposed method of mounting signs; supporting structures and illumination shall be delineated. (Each sign program shall utilize consistent sign construction techniques, mounting mechanisms and methods of illumination.) c. Intended sign location(s), copy and logo height and dimensions. 2. Sign program in addition to sign permits. Approval of a planned sign program does not waive the requirement to obtain sign permits for individual signs or sign structures. In cases of sites that have no preapproved sign program, all signs shall be regulated in conformance with all other sections of this Code until such time as a planned sign program is submitted, reviewed and approved. 3. Placement standards. The/any principal park, center, mall, subdivision or apartment complex advertising sign(s) shall: a. Be placed as near as possible to the main service drive(s) providing principal access to the center without being set in a vision triangle. b. Not be placed in nor overhang public right-of-way notwithstanding section 10-23-15 of this chapter. c. Be placed on any lease space or lot that is part of the development to which the sign directly pertains (and thereby not be considered as "off premises" and thus allowable only via issuance of a variance permit). 4. Center freestanding sign(s) dimensions. Maximum area, height and number allowed standards for primary freestanding center signs shall be the same as for freestanding pole or monument signs allowed in the same zone as listed in tables located in section 10-23-20 of this chapter. 5. Additional freestanding signage. In addition to a center sign, a freestanding sign for each (separate) building within the center is permitted, provided that the same is a monument style sign measuring eight feet or less in height and 64 square feet or less in area. 6. Directory signage. Wall directory signs, for listing all tenants who have offices/businesses within a center, shall be permitted as a standard wall sign or may be allowed as separate freestanding sign from any center sign provided that: a. Only one such sign shall be allowed per street frontage of the center unless the center has more than 500 feet of continuous frontage in which case another such sign may be allowed provided it is placed at least 300 feet away from the other tenant sign. b. The directory sign(s) do/does not exceed 32 square feet in area and eight feet in height, or, if in a vision clearance triangle three feet in height. 7. Wall signage. Each individual business within a center shall be permitted to have wall signage in accordance with tables located in section 10-23-20 of this chapter. 8. Sign design(s). Center signs shall incorporate materials, colors and a design motif that is compatible with and complements the architectural theme and style of the complex which the sign serves to identify/advertise. 9. Temporary signs. All temporary signs shall comply with section 10-23-19 of this chapter; however, such temporary signs may be placed as near as possible to each main service drive(s) where it intersects with a public street that provides access to but does not vector through a shopping center (providing principal access to the center without being set in a vision triangle). 10. Binding effect. After approval of a planned sign program, no signs shall be constructed except in conformance with such plan. Upon approval, the sign program shall apply to all tenants. This planned sign program shall be included in the lease for each individual tenant. Proof of said inclusions shall be submitted to the planning department by the lessor.
(Ord. No. 4617, § 1(Exh. A), 10-4-2021; Ord. No. 4671, § 1(Exh. A), 5-16-2022)
Ask a question about Nampa law
Corpus searches the Nampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
