§ 4-12-06 — Annual inspections and maintenance standards

Code of Ordinances of the City of Nampa, Idaho (Codified through Ordinance No. 4907, adopted January 5, 2026 (Supp. No. 16, Update 1)) · Nampa Code of Ordinances § 4-12-06

Corpus is an independent public-information project, not the official City of Nampa website. Stable reference: corpuslaw.us/code/1e0b9e43-64a5-4797-a58c-630a350a13ee

4-12-06. - Annual inspections and maintenance standards.

A. Upon presentation of proper city credentials or identification to the owner(s) or occupant of any vacant building, and with the consent of the owner(s) or occupant, the building code official, fire code official, or designated representatives may enter at a reasonable time any vacant building, structure, or premises in the city to perform any duty provided for under this chapter. The building official or the building official's representative may also simultaneously conduct inspections of buildings in the manner provided for by law, including as set forth in the International Fire Code, International Building Code, or other applicable provision of this Code. In any case where entry is denied by the vacant building vacant building owner(s) or occupant, the building official or the building official's representative shall not enter without a warrant or other appropriate judicial authorization first having been obtained after reasonable grounds have been shown that a condition exists on the premises that is dangerous or presents a hazard to health or safety, or that the inspection sought is a part of a comprehensive program to have all buildings in the city comply with minimum standards as prescribed by this chapter, or other sufficient grounds under the circumstances then existing. B. Every vacant building shall conform to the standards of this chapter and the Adopted International Property Maintenance Code (IMPC). Each and every owner of a vacant building shall cause his or her property to be inspected not less frequently than annually by a duly licensed and capable private inspector, licensed architect, or licensed engineer, who shall, within 30 days after said inspection, submit a written inspection report to the building official verifying that the building is in compliance with this chapter. In the event a vacant building does not conform to these standards, or no such report is timely submitted, the building official may order the owner(s) to provide inspection report(s) for the property and present satisfactory evidence of compliance with these standards in the form of an inspection report created by a duly licensed and capable private inspector, engineer, or other consultant, verifying that the building is in compliance herewith. The building official or the building official's representative may require expertise of other governmental or private inspectors or agencies, as necessary, to ensure compliance with the following standards: 1. Sanitary facilities: a. All plumbing fixtures connected to an approved water system, sewage system, or natural gas utility system shall be installed in accordance with applicable codes and ordinances and maintained in sound condition and good repair. b. All plumbing fixtures connected to an approved water system, sewage system, or natural gas system not installed or maintained in accordance with applicable codes and ordinances shall be removed and the service terminated, and the pipes capped in the manner prescribed by applicable codes and ordinances. 2. Electrical system: a. Every existing outlet and fixture shall be properly connected and wiring, and service lines shall be installed and maintained in accordance with applicable codes and ordinances. b. Outlets and fixtures not installed or maintained in accordance with applicable codes and ordinances shall be removed and the services terminated in the manner prescribed by applicable codes and ordinances. 3. Safety from fire: a. No vacant building or premises on which a vacant building is located shall contain any space used for the storage of flammable liquids or any other materials that could constitute a safety or fire hazard. b. Heating facilities or heating equipment in vacant building(s) shall be removed or maintained in accordance with applicable codes and ordinances and any fuel supply shall be removed or terminated in accordance with applicable codes and ordinances. 4. All vacant buildings shall be properly weather protected to prevent deterioration of the exterior and interior of the building. This weather protection shall be approved by the building official and shall include all roof and wall assemblies. 5. All vacant buildings shall be closed to unauthorized entry according to the following standards: a. All windows or similar openings shall be protected by intact glazing (glass). All windows or similar openings lacking intact glazing (glass), the sills of which are located ten feet or less above grade, stairway, landing, ramp, porch, roof, or other similarly accessible area, shall provide resistance to entry equivalent to or greater than that of a solid sheet of three-quarter inch plywood. Any such material used to protect windows or similar openings shall be painted or finished in a color matching the existing structure to protect it from weather deterioration, cut to completely cover the opening, and securely fastened by current FEMA boarding up procedures. The sheathing material and exterior finish material of boarded up openings shall meet the International Residential Code and/or International Building Code requirements. b. Doors and service openings with thresholds located ten feet or less above grade, a stairway, landing, ramp, porch, roof or similarly accessible area, shall provide resistance to entry equivalent to or greater than that of a closed single panel solid core door one and three-quarters inches thick equipped with a half-inch throw deadbolt. Exterior doors, if openable, may be closed from the interior of the building by securing them to the doorframe using approved hardware. c. There shall be one operable door into each building and into each housing unit. If an existing door is operable, it may be used and secured with a suitable lock such as a hasp and padlock or a one-half inch deadbolt or dead latch. All locks shall be kept locked. All doors shall be maintained as operable doors and shall conform to minimum building code standards. All doors shall be painted in a color matching the existing structure to protect it from weather deterioration and shall be equipped with a lock as described above. 6. All debris, combustible materials, hazardous or noxious vegetation, litter and garbage shall be removed from vacant buildings and the premises on which a vacant building is located and further accumulation of the same prevented. Further, each owner of any vacant building shall remove or destroy all dead grass, weeds, shrubs, bushes, trees or vegetation upon property containing the vacant building, and which is a fire hazard or a menace to public health, safety and welfare. 7. All vacant buildings shall have plainly visible house numbers or address numbers as required by the local fire code or other applicable law. 8. All vacant buildings with store front windows shall install a form of art or window dressing that is aesthetically pleasing and allows visibility for security of the building. Design proposals for these items must be submitted for approval to the planning and zoning department for approval by the city arts and historic preservation committee prior to installation. 9. The owner(s) shall refer to city sign ordinance for the removal of signs advertising previous businesses.

(Ord. No. 4689, § 1, 10-3-2022)

Ask a question about Nampa law

Corpus searches the Nampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.