§ 4-2-2 — Amendments to the International Building Code, and International Residential Code, and International Energy Conservation Code

Code of Ordinances of the City of Nampa, Idaho (Codified through Ordinance No. 4907, adopted January 5, 2026 (Supp. No. 16, Update 1)) · Nampa Code of Ordinances § 4-2-2

Corpus is an independent public-information project, not the official City of Nampa website. Stable reference: corpuslaw.us/code/5066b42e-5a2d-4747-99cb-814252e9086d

4-2-2. - Amendments to the International Building Code, and International Residential Code, and International Energy Conservation Code.

IBC/IRC section 101.1, "Title". These regulations shall be known as the building code of Nampa City, hereinafter referred to as "this code". IBC section 101.4.4, "Plumbing" is amended as follows: Reference to the international plumbing code shall be replaced with the most current version of the Idaho state plumbing code, as set forth in Idaho Code section 54-2601 et seq., as it may be amended from time to time, as well as all rules and regulations promulgated by the Idaho plumbing board pursuant to the authority granted to it under Idaho Code section 54-2606. Copies of the most current version of the Idaho state plumbing code and the aforementioned rules and regulations are on file and available in the office of the building official, and the same shall be used as the path to compliance for plumbing installations within the City of Nampa. IBC/IRC section 103.2, "Appointment" is deleted and repealed in its entirety. IBC/IRC section 105.2, "Work Exempt from Permit; Sub-Section: "Building" is amended as follows: 105.2 Work Exempt from Permit; Sub-Section: "Building". Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following: 1. Building: One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 200 square feet (18.58 m2). Exception: A building permit and approved permanent footing and/or foundation will be required for accessory structures of any size where permanent electrical wiring, plumbing, and/or HVAC systems are installed. 2. Oil derricks. 3. Retaining walls that are not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding class I, II or IIIA liquids. 4. Water tanks supported directly on grade if the capacity does not exceed 5,000 gallons (18 925 l) and the ratio of height to diameter or width does not exceed 2:1. 5. Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below and are not part of an accessible route. 6. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work. 7. Temporary motion picture, television and theater stage sets and scenery. 8. Prefabricated swimming pools accessory to a group R-3 occupancy that are less than 48 inches (1219 mm) deep, do not exceed 5,000 gallons (18 925 l) and are installed entirely above ground. 9. Shade cloth structures constructed for nursery or agricultural purposes, not including service systems. 10. Swings and other playground equipment accessory to detached one- and two-family dwellings. 11. Window awnings supported by an exterior wall that do not project more than 54 inches (1372 mm) from the exterior wall and do not require additional support of group R-3 and U occupancies. 12. Nonfixed and movable fixtures, cases, racks, counters and partitions not over 5 feet 9 inches (1753 mm) in height. IBC section 108.6, "Work Commencing Before Permit Issuance" is deleted and repealed in its entirety. IBC section 112/IRC section R111, "Connection to Service Utilities" is amended to read as follows: A final inspection and approval is required upon completion and prior to occupancy and use of all buildings and structures. Lack of building official approval may result in the termination of utility services to said building or structure and appropriate legal action per IBC section 113/IRC section 113, and Nampa city code section 4-1-5. IBC section 113/IRC section R112, "Board Of Appeals" is deleted and replaced with the language in Nampa city code section 4-2-5. IRC section and table 302.6, "Dwelling/garage fire separation," is amended to read as follows: Private garages shall be separated from residences and their attic area by means of a minimum ⅝ inch, type X gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than ⅝ inch, type X gypsum board or equivalent. Garages located less than 3 feet from a dwelling unit on the same lot shall be protected with not less than ⅝ inch, type X gypsum board applied to the interior side of exterior walls that are within this area. Penetrations within such walls listed above are required to be protected as required for one-hour construction. Door openings between the garage and residence, shall be equipped with a self-closer, and be constructed of either a solid core wood door not less than 13/8 inch in thickness, solid or honeycombed steel doors not less than 13/8 inch in thickness. Openings from a private garage into a room used for sleeping purposes shall not be permitted. IBC section 1608.2, "Ground Snow Loads" is amended to read as follows: The ground snow load to be used in determining the design snow loads for the city of Nampa shall be 20 psf (pg). IBC section 1612.5, "Flood Hazard Documentation" is deleted and repealed in its entirety. IRC section R104.10.1, "Areas Prone To Flooding" is amended as follows: The building official shall not grant modifications to any provisions related to areas prone to flooding established by table R301.2(1) without the review and approval by the Nampa city floodplain administrator. IRC section R105.3.1.1, "Substantially Improved Or Substantially Damaged Existing Buildings In Areas Prone To Flooding" is amended as follows: For applications for reconstruction, rehabilitation, addition, or other improvement of existing buildings or structures located in an area prone to flooding as established by table R301.2(1), the Nampa city floodplain administrator shall examine or cause to be examined the construction documents of the proposed work. For buildings that have sustained damage of any origin, the value of the proposed work shall include the cost to repair the building or structure to its pre-damaged condition. All substantially improved or reconstruction of existing structures shall be made in accordance with the Nampa city floodplain ordinance. IRC section R202, definition for "Townhouse" is deleted in its entirety and replaced by: TOWNHOUSE: A single-family dwelling unit constructed in a group of two (2) or more attached units in which each unit extends from foundation to roof and with a yard or public way on not less than two sides where units are separated by property lines and with open space on at least two (2) sides. IRC table R301.2(1), is amended to read as follows: Table R301.2(1) Climatic And Geographic Design Criteria GROUND SNOW LOAD o : | 20 PSF. Design roof load shall not be less than a uniform snow load of 25 psf. WIND DESIGN SPEED d (mph): | 90 Wind speed from the basic wind speed map [Figure R301.2(4)A]. Wind exposure category shall be determined in accordance with Section R301.2.1.4 WIND DESIGN TOPOGRAPHIC EFFECTS k : | NO In accordance with Section R301.2.1.5 SPECIAL WIND REGION l : | NO WIND-BORNE DEBRIS ZONE m : | NO SEISMIC DESIGN CATEGORY f : | B In accordance with Section R301.2.2.1 SUBJECT TO DAMAGE FROM: WEATHERING a : | Severe as determined from the Weathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 or C652. FROST LINE DEPTH b : | 24 inches TERMITE c : | Slight to Moderate Based on history of local subterranean termite damage. WINTER DESIGN TEMP e : | 10 degrees F The outdoor design dry-bulb temperature shall be selected from the columns of 97½-percent values for winter from Appendix D of the International Plumbing Code or as determined by the Building Official. ICE BARRIER UNDERLAYMENT REQUIRED h : | NO In accordance with Sections R905.2.7.1, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and 21 R905.8.3.1, where there has been a history of local damage from the effects of ice damming. FLOOD HAZARDS g : | Floodplain ordinance effective 4/18/2011, with current revisions and FIRM maps as currently adopted. AIR FREEZING INDEX i : | 860 Based on the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99%) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32° Fahrenheit)" at www.ncdc.noaa.gov/fpsf.html. MEAN ANNUAL TEMP j : | 51.8 degrees F Based on the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)" at www.ncdc.noaa.gov/fpsf.html. MANUAL J DESIGN CRITERIA n : Elevation: | 2867 Latitude: | 44 deg. N. Winter heating: | 11 deg. Summer cooling: | 95 deg. Altitude correction factor: | .98 Indoor design temperature heating: | 70 deg. Indoor design temperature cooling: | 75 deg. Heating temperature difference: | 60 deg. Cooling temperature difference: | 20 deg. Wind velocity heating: | 15.0 Wind velocity cooling: | 7.5 Coincident wet bulb: | 63 deg. Daily range: | High Winter humidity: | 50% Summer humidity: | 50% For SI: 1 pound per square foot = 0.0479 kN/m2, 1 mile per hour = 1.609 km/h. a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The weathering column shall be filled in with the weathering index (i.e., "negligible," "moderate", or "severe") for concrete as determined from the weathering probability map [figure 8301.2(3)]. The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 or C652. b. The frost line depth may require deeper footings than indicated in figure R403.1(1). The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table with "very heavy", "moderate to heavy," "slight to moderate," or "none to slight" in accordance with figure R301.2(6) depending on whether there has been a history of local damage. d. The jurisdiction shall fill in this part of the table with "moderate to severe," "slight to moderate," or "none to slight" in accordance with R301.2(7) depending on whether there has been a history of local damage. e. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [figure R301.2(4)]. Wind exposure category shall be determined on a site-specific basis in accordance with section R301.2.1. f. The outdoor design dry-bulb temperature shall be selected from the columns of 97½ percent values for winter from ASHRAE-97 handbook of fundamentals. g. The jurisdiction shall fill in this part of the table with the seismic design category determined from section 8301.2.2.1. h. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction's entry into the national flood insurance program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the currently effective FIRM and FBFM, or other flood hazard map adopted by the community, as may be amended. i. In accordance with sections R905.2.7.1, R905.4.3, R905.5.3, R905.6.3, R905.7.3 and R905.8.3, for areas where the average daily temperature in January is 25°F (-4°C) or less, or where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "yes." Otherwise, the jurisdiction shall fill in this part of the table with "no." j. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from figure R403.3(2) or from the 100-year (99%) value on the National Climatic Data Center data table "air freezing index-USA method (base 32° Fahrenheit)" at www.ncdc.noaa.gov/fpsf.html. k. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "air freezing index-USA method (base 32° Fahrenheit)" at www.ncdc.noaa.gov/fpsf.html. Repeal Section R403.1.1, IRC One-And-Two-Family Dwelling Building Code Amendment, Section R403.1.1, Minimum Size, and replace as follows: R403.1.1 Minimum size. Minimum sizes for concrete and masonry footings shall be as set forth in Table R403.1 and Figure R403.1(1). The footing width (W) shall be based on the load bearing value of the soil in accordance with Table R401.4.1. Spread footings shall be at least six (6) inches in thickness (T). Footing projections (P) shall be at least two (2) inches and shall not exceed the thickness of the footing. The size of footings supporting piers and columns shall be based on the tributary load and allowable soil pressure in accordance with Table R401.4.1. Footings for wood foundations shall be in accordance with the details set forth in Sections 403.2 and Figures R403.1(2) and R403.1(3). IBC 602.1.2 Alternative provisions. As an alternative to the construction types defined in Sections 602.2 through 602.5, buildings and structures erected or to be erected, altered or extended in height or area may be classified as construction type IV-A, IV-B, or IV-C in accordance with the provisions adopted in 9-1A-2 of this Chapter. Buildings and structures classified as construction type IV-A, IV-B, or IV-C shall comply with the provisions adopted in 9-1A-2 of this Chapter and all other applicable provisions of this code. Delete IECC Section R403.3.1 and replace with the following: R403.3.1 Duct insulation requirements. Supply and return ducts located in an attic space shall have an R-value of not less than R-8. Delete IECC Section R403.3.6, Ducts buried within ceiling insulation. Delete IECC Section R403.3.7, Ducts located in conditioned space.

(Ord. 3942, 12-20-2010; Amd. Ord. 4158, 1-5-2015; Ord. 4213, 12-7-2015, eff. 1-1-2016; Ord. 4353, 12-4-2017, eff. 1-1-2018; Ord. 4539, 11-16-2020; Ord. No. 4624, § 2, 11-1-2021)

Ask a question about Nampa law

Corpus searches the Nampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.