§ 4-4-5 — Additional provisions
Code of Ordinances of the City of Nampa, Idaho (Codified through Ordinance No. 4907, adopted January 5, 2026 (Supp. No. 16, Update 1)) · Nampa Code of Ordinances § 4-4-5
Corpus is an independent public-information project, not the official City of Nampa website. Stable reference: corpuslaw.us/code/34087cfa-5257-4484-b1f9-5483bbd525ca
4-4-5. - Additional provisions.
In addition to the provisions of the National Electrical Code, the following shall apply: A. Special safeguards for electrical installations. In addition to the provisions specified in the electrical codes of the city, the electrical inspector may require additional safeguards under special conditions and/or unusual circumstances which require additional safeguards for the protection of the health, safety and general welfare of the city. B. Location of service equipment. Service disconnection means shall not be installed in clothes closets, cupboards, bathrooms or attics. They shall be located in a readily accessible area. C. Power of building official to disconnect wiring. If the electrical inspector finds any part of any electric wiring, apparatus or fixtures in or about any building to have been installed without a permit, or not in accordance with the rules and regulations as provided by this Code or the State of Idaho, or if any electric installations are found to be dangerous to life or property, the building official is authorized to request that Idaho Power disconnect the electrical energy to the structure. He shall at the same time give written notice of such disconnection to the owner or occupant of the building in which such disconnection is being made and shall post the building with the notice and order issued to the electric utility. After such disconnected wiring, apparatus or fixtures have been replaced, repaired or rehabilitated to such put in a condition that they are deemed safe by the electrical inspector, Idaho Power will be notified by means of a final inspection and approval by the electrical inspector. D. Commercial buildings. This section covers all buildings or that part of a building or structure designated or intended for use by persons for commercial purposes. Included are all occupancies as defined within the current edition of the International Building Code except: group R, and group U, division 1, occupancies. E. Wiring methods. All wiring within structures housing the occupancies referenced in this section shall have their wiring installed within a raceway as defined in the NEC installed in other methods which have been approved by the building official and which meet the intent of this section. Wiring methods within group R and group U occupancies shall be dictated by the requirements of the adopted version of the National Electric Code.
(Ord. 3762, 12-17-2007; Ord. 4406, 11-5-2018)
Ask a question about Nampa law
Corpus searches the Nampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.