15.04.010. - International Building Code adopted.

A. Adoption. In order to protect the health, safety and welfare of the public and to prescribe regulations governing Building and other construction, the city council hereby adopts the 2018 International Building Code (IBC), prepared by the International Code Council, Inc., as adopted by the State of Idaho through the Idaho Building Code Board, together with any amendments or revisions to the IBC made by the Idaho Building Code Board through the negotiated rulemaking process, is adopted with the following exceptions or amendments. 1. Section 103.2 is not adopted. 2. Section 103.3 is not adopted. 3. Section 107.1 is amended to read as follows. 107.1. General. Submittal documents consisting of construction documents, statement of special inspections, geotechnical report, structural observation programs and other data shall be submitted in one (1) paper set and one (1) PDF of the plan set in an approved electronic format for each application for a permit. The architectural construction documents shall be prepared by an architect licensed to practice by the State of Idaho. The Building official shall have the option to stipulate that an Idaho licensed architect may submit construction documents that are proven to strictly adhere to the IBC provisions of section 2308; Conventional Light-Frame Construction. The Building official shall have the option to stipulate that an Idaho licensed engineer in the appropriate engineering discipline (structural, mechanical, electrical, civil, geotectonic, acoustical, etc.) of his or her expertise may submit supplemental construction documents supportive and complementary to the architect's construction documents. Where special conditions exist, the Building official may authorize a registered professional engineer acting within the discipline of his or her expertise and at the stipulation of the Building official acting jointly or in association with a licensed architect to prepare construction documents and require site construction observation for Buildings or shelters not intended, designed or constructed for human habitation or occupancy. Exception. The Building official is authorized to waive the submission of construction documents and other data not required to be prepared by a registered design professional of any architectural or engineering service in the erection, enlargement, alteration or repair of any Building where such Building to be or is used as a single family residence not exceeding three (3) stories in height and multiple height and multiple family residence of three adjoining dwelling units not exceeding three (3) stories in height or as a farm Building or for the purpose of out Buildings or auxiliary Building in connection with such residence or farm premises or if it is found that the nature of the work applied for is such that reviewing of construction documents is not necessary to obtain compliance with this Code. Those individuals who furnish only interior design or decoration or space planning or space design services within existing Structures which do not involve the construction or adherence to requirements of the international Building code (IBC) including the Americans with disabilities act (ADA), American national standard accessible and usable Building and facilities ICC/ANSI-A117 will not be required to be a registered design professional. This exemption only allows the use of moveable partitions, rails, counters, cabinets, space dividers, furniture and similar types of equipment which do not exceed a height of five feet, nine inches above floor in the execution of the plans or design of a particular space or the creation of exits corridors, stairways and disturbances of existing structural components as defined by the IBC. 4. Section 107.3.4.1 is amended to read as follows. 107.3.4.1 General. When it is required that documents be prepared by a registered architect, the Building official shall be authorized to require that the owner engage and designate on the Building permit application a registered architect who shall act as the registered design professional in responsible charge. If the circumstances require, the owner shall designate a substitute registered architect or professional engineer in responsible charge who shall perform the duties required by the Building official. The Building official shall be notified in writing by the owner or the architect of record if the person who is in responsible charge is changed or is unable to continue to perform the required duties. 5. Section 406.3.2.1 Separation. Replace section 1 with the following. The private garage shall be separated from the dwelling unit and its attic area, including supporting members with materials approved for one-hour fire-resistive construction on the garage side and a self-closing, tight-fitting solid-wood door 13/8 inches in thickness, or a self-closing, tight-fitting 20-minute fire-rated door, or solid or honeycomb steel doors not less than 13/8 inches (34.9 mm) thick, or doors in compliance with section 716.5.1 and 716.5.3.1. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. 6. Section 1809.5 Frost Protection. Delete method 1 and replace with the following. 1. Extending below the frost line of the locality, with a minimum twenty-four (24) inches from ground surface to the bottom of a footing. 7. Add a new section 1905.1.9 Minimum Reinforcement as follows. All continuous footings will require a minimum of two (2) continuous horizontal reinforcing bars. Footings supporting columns and piers shall contain no less than two (2) #4 rebar installed each way, not to exceed twelve (12) inches maximum spacing. Minimum reinforcement for foundation walls (unless closer spacing is specified by design or engineering specifications) which do not exceed four (4) feet in height shall be four (4) feet on center for vertical reinforcement and two (2) feet on center for horizontal reinforcement. One (1) continuous row of horizontal #4 rebar shall be located between three (3) inches and six (6) inches of top and bottom of wall. Foundation walls over four (4) feet in height (unless closer spacing is specified by design or engineering specification) shall be eighteen (18) inches minimum on center for horizontal and vertical reinforcement. Reinforcing bars shall be a minimum size of #4 and may be a minimum grade forty (40). One continuous row of horizontal #4 rebar shall be located between three (3) inches and six (6) inches of top and bottom of wall. No less than two (2) #4 rebar shall be installed around door, window, and similar sized openings.

(Ord. 1405, 2020; Ord. 1328, 2017)

Ask a question about Post Falls law

Corpus searches the Post Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.