8.16.120. - Service buildings.
Each Trailer Court must be provided with one or more Service Buildings containing the requisite number of plumbing fixtures and other service equipment. The Service Buildings must conform in general to the following requirements: A. Location. Buildings should be located not more than two hundred (200) feet from any Dependent Trailer Coach spaces. B. Construction. The materials and methods used in the construction of Service Buildings must conform to local building codes for buildings of this nature. They must have an interior finish which is moisture resistant and can be easily cleaned. All rooms of Service Buildings must be ventilated and all exterior openings provided with screens. C. Facilities. Separate men's and women's toilet rooms must be provided and distinctly marked. These rooms must be separated by a sound resistant wall. A vestibule or screen wall must be provided to prevent direct view into the toilet rooms when exterior doors are open. 1. Plumbing Fixtures. a. Every Trailer Court must provide adequate toilet and laundry facilities. In no instance should there be less than one laundry unit (laundry tray or washing machine); one water closet, one lavatory and one shower for women; and one water closet, one lavatory and one shower for men. A slop water closet (water closet with seat removed) must be provided in each Service Building. The slop water closet should be in a separate room of the Service Building with a single direct opening to the outside. b. The facilities listed above will accommodate any number of Independent Trailer Coaches, and up to ten (10) Dependent Trailer Coaches. One water closet must be provided for each sex for every ten (10) additional Dependent Trailer Coaches. (Urinals for men may be substituted for one-third (⅓) of these water closets.) c. One lavatory must be provided for each sex for every ten (10) additional dependent coaches; and one shower or bathtub for each sex for every twenty (20) additional dependent coaches. A laundry unit must be provided for every twenty (20) additional Trailer Coach Spaces. d. All water closets and bathtubs or showers for women, and all water closets and bathtubs for men must be located in separate compartments, with self-closing doors. Gang type shower compartments may be used for men. Individual shower stalls must be approximately three (3) feet by three (3) feet. Showers for women must have a dressing compartment with stool or bench. The room containing the laundry units must be separated from the toilet rooms, and have an exterior entrance only. e. All plumbing installations shall conform to the local plumbing code. 2. Electrical. All electrical installations shall conform to the local electrical code. 3. Heating. Heating facilities capable of maintaining a temperature of seventy (70) degrees in cold weather should be provided. 4. Hot Water. a. Facilities should provide for the continuous supply of three (3) to five (5) gallons of hot water per Trailer Coach Space. b. Hot water at a temperature of about one hundred eighty (180) degrees should be provided for clothes washing equipment.
(Prior code § 5-3-4(D))
Ask a question about Post Falls law
Corpus searches the Post Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.