§ 12-32 — Electrical Code Ordinance Adopted

Code of Ordinances, City of Aurora, Illinois; partial · Aurora Code of Ordinances § 12-32

Corpus is an independent public-information project, not the official City of Aurora website. Stable reference: corpuslaw.us/code/1af0219f-6617-4a5b-8010-c7ba10d48074

Sec 12-32 Electrical Code Ordinance Adopted

That certain document, two (2) copies of which are on file in the office of the Building Code Official, being marked and designated as the City of Aurora Electrical Ordinance. 2023 NFPA -70 National Electrical Code; As published by the National Fire Protection Association and adopted as the Electrical Ordinance of the City of Aurora, Illinois in the State of Illinois: for the control and regulation of installation and/or alteration of electrical systems and electrical equipment; for the utilization of electricity for light, heat or power. Each and all of the regulations, penalties, conditions and terms of said edition of NFPA-70 are hereby referred to and amended in part hereof as if fully set out in this article, with the additions, insertions, deletions, and changes prescribed in ARTICLE III. Sec. 12-31 through 12-100.Ord. No. O92-37, § 1, 6-2-92; Ord. No. O99-41, §§ 1, 11, 6-8-99). Article 100 Definitions added: Nearest the Point of Entrance - Within 5 feet. 110.3(D) is added to read: Examination and Inspection of Non-Labeled Manufacturing Equipment. (a) Conditions deemed as posing an imminent danger shall be required to be removed from service until repaired; OR until labeled from an IAS or OSHA Nationally Recognized Testing Laboratory or field tested from a third-party testing company as accepted by the Authority Having Jurisdiction. (b) For Non-Labeled Manufacturing Equipment, equipment owner and equipment supplier shall verify that OSHA regulations are being met without assessment or inspection by the City of Aurora personnel. Aurora's inspection responsibilities will end at the connection to the permanently installed power feed for the equipment. The suitability of the power to the equipment shall be the responsibility of the owner of the equipment or the manufacturer and shall be verified by the equipment's owner prior to installation. (1) Non-Labeled Manufacturing Equipment may NOT be installed: a. In hazardous locations, b. If equipment uses propane, gas or burns fossil fuels. 210.8(D)(6) is amended to read: Sump pumps - GFCI protection shall be provided at the panel and a single receptacle. 210.23(F) is added to read: Existing 12 AWG branch circuits. Existing branch circuits with 12 AWG conductors that cannot be completely traced throughout the circuit shall be served by no more than 15 ampere breakers. 225.6(A) is amended to read: (a) For 1000 volts, nominal, or less, 10 AWG copper or 1/0 AWG aluminum for spans up to 15 m (50 ft) in length, and 8 AWG copper or 1/0 AWG aluminum for a longer span unless supported by a messenger wire. (b) For over 1000 volts, nominal, 6 AWG copper or 1/0 AWG aluminum where open individual conductors, and 8 AWG copper or 1/0 AWG aluminum where in cable. 225.10 is amended to read: The installation of outside wiring on surfaces of buildings (or other structures) shall be permitted for circuits not exceeding 1000 volts, nominal, as the following: (a) Auxiliary gutters (b) Busways (c) Cable trays (d) Cablebus (e) Intermediate metal conduit (IMC) (f) Liquidtight flexible metal conduit (LFMC) (g) Liquidtight flexible nonmetallic conduit (LFNC) (h) Messenger-supported wiring (i) Reinforced thermosetting resin conduit (RTRC) (j) Rigid metal conduit (RMC) (k) Rigid polyvinyl chloride conduit (PVC) (l) TC-ER cable-limited to a manufactured HVAC system (m) Wireways 230.2(F) is added to read: Buildings with multiple electrical services shall be provided with a shunt trip that simultaneously opens all electrical services including any emergency and standby power systems. Shunt trip shall be of a mushroom style push button provided with a protective cover. Button shall be identified with a sign that reads "EMERGENCY POWER SHUTDOWN SWITCH FOR FIRE DEPT USE ONLY." 230.23 (B) Minimum Size is amended to read: The conductors shall not be smaller than 3 AWG copper or 1/0 AWG aluminum. Section 230.31(B) Minimum Size is amended to read: The conductors shall not be smaller than 3 AWG copper or 1/0 AWG aluminum. Section 230.43 Wiring Methods for 1000 Volts, Nominal, or Less is amended to read: Service-entrance conductors shall be installed in accordance with the applicable requirements of this Code covering the type of wiring method used and shall be limited to the following methods: (a) Rigid metal conduit (RMC) (b) Intermediate metal conduit (IMC) (c) Busways (d) Auxiliary gutters (e) Rigid polyvinyl chloride conduit (PVC) - Shall be schedule 80 (f) Miner-insulated, metal-sheathed cable, Type MI (g) High density polyethylene conduit (HDPE) - Shall be schedule 80 (h) Reinforced thermosetting resin conduit (RTRC) (i) Flexible bus systems 230.51(D) is added to read: All service entrance conduit for overhead service drops shall be supported by galvanized 2 piece back-straps or an approved equal. 250.8(B)(1) is added to read: Sheet-metal strap type ground clamps shall not be used for connecting a grounding electrode conductor to a grounding electrode. 250.50(A) is added to read: Unless otherwise accepted by the building official, a concrete encased electrode shall be installed in new structures with an electrical service. 250.64(A) is amended to read: Aluminum and copper-clad aluminum is not permitted to be used as a grounding electrode conductor. 250.192 Underground/Under-slab/Concrete Encased Raceway is added to read: A conductor to serve as a 100% redundant Equipment Grounding conductor shall be installed in all underground raceways and raceways in concrete. Section 310.3(A) is amended to read: The minimum size of conductors for voltage ratings up to and including 2000 volts shall be 14 AWG copper or 1/0 AWG aluminum or copper-clad aluminum, except as permitted elsewhere in this Code. 310.3(A)(1) is added to read: For individually metered units of R-2, R-3 or R-4 uses (as defined in the IBC), the minimum size conductors shall be 3 AWG copper or 1/0 aluminum or copper-clad aluminum. 310.12 is deleted. 310.15(C)(1) add the following after second paragraph: Fill exceeding 9 conductors may occur only as an engineered design alternative per Aurora electrical administrative provisions 105, when engineering calculations are provided in conformance with fill and amperage derating per Chapter 9 of the NEC. Table 310.15(C)(1) is revised to read: Number of Conductors | Percent of Values in Table 310.16 Through Table 310.19 as Adjusted for Ambient Temperature if Necessary 4-6 | 80 7-9 | 70 10-above | Only permitted through engineered design 314.3 is amended to read: Nonmetallic shall not be installed, except in corrosive environments when approved or in non-grounded circuits when they are permitted to remain. 320.10 is amended to read: Type AC cable shall not be permitted where included as a factory assembled sub-component of a manufactured system. Exception (1) Except where included as a factory assembled sub component of a manufactured system. 322 is deleted. 324 is deleted. 326 is deleted. 330.10 is amended to read: Type MC cable shall be permitted as follows: (a) When fished into existing walls with not more than (6) six feet exposed. (b) Where included as a factory assembled sub-component of a manufactured system. (c) For branch circuits when remodeling existing owner-occupied one-and-two family dwellings. (d) Where approved by the building official. 334 is deleted. 340.10 is amended as follows: Uses Permitted: Type UF cables shall be permitted when remodeling existing one- and two-family dwellings, only in exterior applications. 348.10 is amended to read: Uses Permitted: FMC shall only be permitted when fished into existing wall and ceiling spaces with not more than (6) six feet exposed. 350.10 is amended to add (5): (5) LFMC shall only be permitted in lengths not to exceed (6) six feet. 352.10 is amended as follows: When permitted the transition at grade shall be 90 degree galvanized rigid metal conduit or Schedule 80 PVC. Exception (1) Conduits and sleeves used exclusively for utility cables. Exception (2) Conductors encased in concrete at Light Pole Bases. (A) deleted (D) deleted (E) deleted (F) deleted (G) deleted (I) deleted (J) deleted Section 356.10 (5) is amended to read: Installed in lengths not longer than 1.8 m (6 ft) where secured in accordance with 356.30. 356.12 (3) is amended to read: In lengths longer than 6 feet. 358.42(A) is added to read: EMT shall not be installed using indenter type couplings and connectors. 362 is deleted and not permitted. 378 is deleted and not permitted. 382 is deleted and not permitted. 386.60(A) is added to read: Grounding. All surface metal raceways shall contain an equipment grounding conductor sized per table 250.122. 388 is deleted and not permitted. 393 is deleted and not permitted. 394.10 is amended to read: Uses Permitted. New installations of Knob-and-tube wiring shall not be installed. Existing Knob-and-tube wiring shall not be extended or modified. 625.40(A) is added to read: The EVSE branch circuit shall be at minimum provided with a 3/4" raceway and a 2-1/8" x 4 11/16" minimum box. 690.31(H) is added to read: EMT shall be permitted for on-and-two family dwellings. 695 Fire Pumps: shall be amended as follows: Section 695.5 (B) (1) Fire pump meter or cabinet: shall be sized in accordance with table 430.251 (B) Conversion of Polyphase Design b, c, and d Maximum Locked Rotor Currents. (Ord. No. O18-014, § 1(Exh. A), 1-23-18) Editor's note— Ord. No. 018-014, § 1(Exh. A), adopted January 23, 2018, repealed the former § 12-31, and enacted a new § 12-31 as set out herein. The former § 12-31 pertained to definitions and derived from Ord. No. O92-37, § 1, 6-2-92.

HISTORY Amended by Ord. O25-082 on 12/9/2025

Ask a question about Aurora law

Corpus searches the Aurora sections it holds and shows the ones that match, with their citations. Free, no sign-in.