Sec. 18-21. - Installation of machines.

(a) Each machine shall be completely enclosed by a cabinet and shall be vented with proper intake outlet facilities. Groups of machines may be entirely enclosed or supported on all open sides by an enclosure topped with a hood vented as provided for each individual machine. (b) The machines must be so constructed as to prevent the loading door from being opened during the normal cycle of operation. Each machine shall be equipped with a transparent door or port to allow visual examination of the status of the cleaning cycle. (c) Each machine must be so designed and constructed as to prevent the leakage of liquids, gas or vapors. (d) Any connection of each machine with the water supply system must be equipped with an air gap or vacuum breaker in the line upstream from the condensor; with no control valves down stream from such gap or breaker. Wastewater shall be discharged through an air gap.