Sec. 22-304.1.1. - Unsafe conditions.
The following conditions shall be determined as unsafe and shall be repaired or replaced to comply with the International Building Code and International Residential Code as adopted: (1) The nominal strength of any structural member is exceeded by nominal loads, the load effects or the required strength; (2) The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations is not capable of resisting all nominal loads or load effects; (3) Structures or components thereof that have reached their limit state; (4) Siding and masonry joints including joints between the building envelope and the perimeter of windows, doors and skylights are not maintained, weather-resistant or watertight; (5) Structural members that have evidence of deterioration or that are not capable of safely supporting all nominal loads and load effects; (6) Foundation systems that are not firmly supported by footings, are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects; (7) Exterior walls that are not anchored to supporting and supported elements or are not plumb and free of holes, cracks or breaks and loose or rotting materials, are not properly anchored or are not capable of supporting all nominal loads and resisting load effects; (8) Roofing or roofing components that have defects that admit rain, roof surfaces with inadequate drainage, or any portion of the roof framing that is not in good repair with signs of deterioration, fatigue or without proper anchorage and incapable of supporting all nominal loads and resisting all load effects; (9) Flooring and flooring components with defects that affect serviceability of flooring components that show signs of deterioration or fatigue, are not properly anchored or are incapable of supporting all nominal loads and resisting all load effects; (10) Veneer, cornices, belt courses, corbels, trim, wall facing and similar decorative features not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; (11) Overhand extensions or projections including, but not limited to, trash chutes, canopies, marquees, signs, awnings, fire escapes, standpipes and exhaust ducts not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; (12) Exterior stairs, decks, porches, balconies and all similar appurtenances attached thereto, including guards and handrails, are not structurally sound, not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; or (13) Chimneys, cooling towers, smokestacks and similar appurtenances not structurally sound or not properly anchored, or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects.
(C.B. No. 2016-115, § 1(Exh. 1), 6-6-16)
Ask a question about Champaign law
Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.