For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22-603.5 — Combustion air

Code of Ordinances of the City of Champaign, Illinois (Codified through C.B. No. 2026-125, adopted August 18, 2026 (Supp. No. 81, Update 1)) · Champaign Code of Ordinances § 22-603.5

Corpus is an independent public-information project, not the official City of Champaign website. Stable reference: corpuslaw.us/code/bcbda9ff-e3ba-4f9e-87a6-895cfad1a83a

Sec. 22-603.5. - Combustion air.

(a) A supply of air for complete combustion of the fuel and for ventilation of the space containing the fuel-burning equipment shall be provided for the fuel-burning equipment. (b) Prohibited locations. Except as otherwise provided herein, fuel-fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: (1) Sleeping rooms. (2) Bathrooms. (3) Toilet rooms. (4) Storage closets. (c) The requirements or restrictions in subsection (b) in this section shall not apply in the following circumstances: (1) Direct vent appliances that obtain all combustion air directly from the outdoors. (2) Vented room heaters, wall furnaces, vented decorative appliances and decorative appliances for installation in vented solid fuel-burning fireplaces, and provided that the room is not a confined space and the building is not of unusually tight construction. (3) A single listed wall-mounted unvented room heater equipped with an oxygen depletion safety shutoff system and installed in a bathroom provided that the input rating does not exceed six thousand (6,000) BTU per hour (1.76 KW/hr) and the bathroom is not a confined space. (4) A single listed wall-mounted, unvented room heater equipped with an oxygen depletion safety shutoff system and installed in a bedroom provided that the input rating does not exceed ten thousand (10,000) BTU per hour (2.93 KW/hr) and the bedroom is not a confined space. (5) Appliances installed in a dedicated enclosure in which all combustion air is taken directly from the outdoors, in accordance with the Combustion Ventilation and Dilution Air Section of the International Fuel Gas Code, as adopted. Access to such an enclosure shall be through a weather-stripped solid door equipped with an approved self-closing device.

(C.B. No. 2016-115, § 1(Exh. 1), 6-6-16)

Ask a question about Champaign law

Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.