Sec. 22-605.2. - Receptacles.
(a) Every habitable space in a dwelling shall contain at least two (2) separate receptacle outlets as remote from one another as practical to minimize or eliminate the use of extension cords. (b) Every laundry area shall be served by a separate circuit with at least one (1) grounded receptacle or a ground fault circuit interrupter (GFCI) receptacle within six (6) feet of the laundry appliance location. (c) Every bathroom shall contain at least one (1) wall-mounted ground fault circuit interrupter (GFCI) receptacle within three (3) feet of the edge of the sink basin. (d) Every kitchen shall have at least two (2) receptacle outlets on a circuit separate from the circuit serving the refrigerator, and at least one of these receptacles shall be located above the counter space. (e) Receptacle outlets located outdoors, in a garage, crawlspace, unfinished basement, where installed to serve a kitchen counter, or within six (6) feet of a sink, shall be a ground fault circuit interrupter (GFCI) receptacle except as allowed by the National Electrical Code.
(C.B. No. 2016-115, § 1(Exh. 1), 6-6-16)