§ 22-68 — Closing of vacant structures
Code of Ordinances of the City of Champaign, Illinois (Codified through C.B. No. 2026-125, adopted August 18, 2026 (Supp. No. 81, Update 1)) · Champaign Code of Ordinances § 22-68
Corpus is an independent public-information project, not the official City of Champaign website. Stable reference: corpuslaw.us/code/8de0b3e1-f6e6-4ba6-9f1f-b2b4157e3a73
Sec. 22-68. - Closing of vacant structures.
(a) If the structure is vacant and unfit for human habitation and occupancy, the Code Official is authorized to post a placard of condemnation on the premises and order the structure closed up according to the following closing procedures. The owner shall be notified of the order in the same manner as provided for in Section 22-56. The owner may repair or replace doors, windows and/or other openings to the interior of the structure to satisfy the securing requirements of this section. Such repairs or replacements are preferential to other securing methods. Structures repaired in this manner that remain vacant shall not be considered a public nuisance by means of being open to intrusion. An owner may temporarily secure the structure by other means including boarding to prevent the interior of the building from being exposed to the elements or accessible to entrance by trespassers. Residential structures secured in this manner for a period exceeding ninety (90) days shall be subject to the requirements of Vacant Nuisance Residential Buildings registration. Upon failure of the owner to close up the premises in the manner and within the time specified in the order, the property is hereby declared a public nuisance, and the Code Official may cause the premises to be closed and secured through any available public agency or by contract or arrangement by private persons. The cost to the City of taking such action to close and secure the premises shall be charged against the real estate upon which the structure is located and shall be a lien upon such real estate. Residential structures secured by the City that remain boarded for a period exceeding ninety (90) days shall be subject to the requirements of Vacant Nuisance Residential Buildings registration. (b) Minimum securing procedures. Upon being ordered to secure a vacant structure in accordance with this section, the owner shall cause the structure to be secured to at least the following extent: (1) Openings shall be closed with wood structural panels at least one-half-inch thick, fitted in the opening and nailed with screw nails or ring shank nails not further than twelve (12) inches apart along the perimeter of the plywood. Such nails shall enter the blocking or backing behind the plywood to a minimum depth of one (1) inch. Screws may be used in place of ring shank nails or screw nails. (2) The perimeter of the wood structural panel must be caulked, and the wood structural panel must be painted to match the color of the structure. (3) Parts of the building that may fall off the structure must be reattached or removed. (4) Windows, doors and/or other openings to the interior of the structure may be repaired or replaced to original operating condition in lieu of boarding. (c) Barricade securing procedures. Where the opening to the structure may be further damaged from minimum securing procedures by the use of screws or nails or the opening has been subject to repeated intrusions or the code official determines that minimum securing methods cannot adequately secure the opening, then the barricade securing procedure shall be required. (1) Wood structural panels shall be minimum one-half inch thick panels. Boarding framing material shall be minimum nominal two-inch by four-inch solid sawn lumber. Boarding fasteners shall be minimum three-eighths-inch diameter carriage bolts of such a length as required to penetrate the assembly and as required to adequately attach the washers and nuts. All materials shall comply with the International Building Code. (2) The boarding sheet material shall be cut to fit the structure opening neatly or shall be cut to provide an equal overlap at the perimeter of the opening. The opening shall allow the carriage bolt to pass through. The two-by-four strong back framing material shall be cut minimum two (2) inches wider than the opening and shall be placed on the inside of the opening six (6) inches minimum above the bottom and below the top of the opening. The framing and boarding shall be predrilled. The assembly shall be aligned and the bolts, washers and nuts shall be installed and secured. One door to the structure shall be available for authorized entry and shall be secured and locked in an approved manner. [image omitted; see the official code] Recommended Barricade Methods (d) Securing a structure in compliance with this section is not a defense to any other cause of action under this code.
(C.B. No. 2016-115, § 1(Exh. 1), 6-6-16)
Ask a question about Champaign law
Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.
