§ 22-702.4.1 — Emergency escape openings
Code of Ordinances of the City of Champaign, Illinois (Codified through C.B. No. 2026-125, adopted August 18, 2026 (Supp. No. 81, Update 1)) · Champaign Code of Ordinances § 22-702.4.1
Corpus is an independent public-information project, not the official City of Champaign website. Stable reference: corpuslaw.us/code/57cddc8f-3c00-4414-87c7-aaed1807b95c
Sec. 22-702.4.1. - Emergency escape openings.
(a) The minimum net clear opening height dimension shall be twenty-two (22) inches (559 mm). The minimum net clear opening width dimension shall be twenty (20) inches (508 mm). The net clear opening area shall in no case be less than four (4) square feet (0.4 meters squared). (b) Each egress window from sleeping rooms must have a minimum total glass area of not less than five (5) square feet (0.5 meters squared) in the case of ground floor windows and not less than five and seven tenths (5.7) square feet (0.53 meters squared) in all other cases. Exceptions: (1) Buildings equipped throughout with an approved automatic fire suppression system. (2) Owner-occupied, single-family residences. (c) An emergency escape and rescue openings with a finished sill height below the adjacent ground level shall be provided with a window well in accordance with the International Fire Code, as adopted.
(C.B. No. 2016-115, § 1(Exh. 1), 6-6-16)