§ 22-704.4 — Interconnection

Code of Ordinances of the City of Champaign, Illinois (Codified through C.B. No. 2026-125, adopted August 18, 2026 (Supp. No. 81, Update 1)) · Champaign Code of Ordinances § 22-704.4

Corpus is an independent public-information project, not the official City of Champaign website. Stable reference: corpuslaw.us/code/0c8bec9e-df64-4d16-b97e-d61cd7acdb9b

Sec. 22-704.4. - Interconnection.

Where more than one (1) smoke alarm is required by any code to be installed within an individual dwelling unit in Groups R-2, R-3, R-4 and in dwellings not regulated as Group R occupancies, the smoke alarms shall be interconnected in such a manner that the activation of one (1) alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed. Exceptions: (1) Interconnection is not required in buildings which are not undergoing alterations, repairs or construction of any kind. (2) Smoke alarms in existing areas are not required to be interconnected where alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could provide access for interconnection without the removal of interior finishes.

(C.B. No. 2016-115, § 1(Exh. 1), 6-6-16)