For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 37-367 — Access drive design commercial and industrial

Code of Ordinances of the City of Champaign, Illinois (Codified through C.B. No. 2026-125, adopted August 18, 2026 (Supp. No. 81, Update 1)) · Champaign Code of Ordinances § 37-367

Corpus is an independent public-information project, not the official City of Champaign website. Stable reference: corpuslaw.us/code/fe4aca69-9465-4410-a34b-2cd0a0d7d718

Sec. 37-367. - Access drive design commercial and industrial.

Commercial and industrial access drives shall conform with the following requirements: (a) No property shall have more than two (2) access drives per frontage. For the purpose of this section a property shall be defined as: (1) A platted lot under single ownership which is of record on July 29, 1968; or (2) Two (2) or more platted lots or combinations of lots and portions of lots with continuous frontage under single ownership which are of record on July 29, 1968; or (3) An unplatted parcel of land with continuous frontage under single ownership. (b) No access drive shall be less than two hundred (200) feet from any parallel access drive on the same property to the centerline thereof. (c) No access drive shall be located less than one hundred fifty (150) feet from any parallel street thereof; except in cases where an arterial street intersects another street, then no access drive shall be located less than two hundred fifty (250) feet from either intersecting street measured from centerline-to-centerline. (d) No access drive shall be located less than two hundred (200) feet from the base of any bridge incline, measured from the centerline of the access drive to the base of the bridge incline. (e) No access drive shall be located less than four hundred (400) feet from an interchange ramp, measured from centerline-to-centerline. (f) No access drive shall be less than ten (10) feet nor more than the maximum width allowed by Chapter 9 of the Manual of Practice. (g) Standards for access drive construction shall meet the requirements of Chapter 30 of this Code. (h) No access drive shall be permitted in violation of the Subdivision Regulations. (i) If any platted legal lot of record, by reason of location or size, cannot be developed in compliance with the above requirements, access shall be provided at locations which most closely comply with these regulations while maintaining safety and functionality as determined by the City Engineer. Access not in compliance with the above requirements must be approved in writing by the City Engineer. Such access shall be in accordance with Chapter 9 of the Manual of Practice (Vehicular Access Control).

(C.B. No. 2005-073, § 2, 3-15-05; C.B. No. 2006-090, § 1, 4-18-06; C.B. No. 2014-048, § 1, 3-18-14; C.B. No. 2018-149, § 1(Exh. A), 9-18-18)

Ask a question about Champaign law

Corpus searches the Champaign sections it holds and shows the ones that match, with their citations. Free, no sign-in.