14B-21-2110 Glass unit masonry.
The provisions of Section 2110 of IBC are adopted by reference with the following modification: 1. Revise Section 2110.1.1, excluding the exception, to read: "2110.1.1 Limitations. Solid or hollow glass block shall not be used in fire walls, party walls, fire barriers, fire partitions or smoke barriers, or for load-bearing construction. Glass blocks shall be erected with mortar and reinforcement in metal channel-type frames, structural frames, masonry or concrete recesses, embedded panel anchors as provided for both exterior and interior walls or other approved joint materials. Wood strip framing shall not be used in walls required to have a fire-resistance rating by other provisions of this code."