§ 14B-6-605 — Basement construction

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14B-6-605

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/ba044cac-a426-417a-b3c8-56606ecee2b4

14B-6-605 Basement construction.

The following language is adopted as a new Section 605: "605. BASEMENT CONSTRUCTION 605.1 General. In all buildings, basement construction shall comply with the requirements of Sections 605.2 through 605.4. 605.2 Basement columns and bearing walls. In buildings of Type III or V construction with three or more stories above grade plane, all basement columns and basement bearing walls shall be of noncombustible material or of heavy timber construction. 605.3 Multiple basement stories. In buildings with more than one basement story, the floor construction separating the highest basement from the first story above grade plane and all construction below that level shall be of Type IA construction. 605.4 Floor construction. Except in buildings of Group R-5 occupancy, floor construction over basements shall have a fire-resistance rating of not less than 1 hour."

Ask a question about Chicago law

Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.