§ 14R-9-903 — Building elements and materials

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14R-9-903

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/e887163b-2cae-4e1d-851e-6e5d1cdf2a5d

14R-9-903 Building elements and materials.

The provisions of Section 903 of IEBC are adopted by reference with the following modifications: 1. Revise Section 903.1 by replacing "floor" with "story" and "floors" with "stories." 2. Revise Section 903.2 to read: "903.2 Fire partitions in townhouses. Fire separation in Group R townhouses shall be in accordance with Section 903.2.1." 3. Revise Section 903.2.1, excluding the exception, to read: "903.2.1 Separation required. Where the work area is in any multi-story side-by-side attached dwelling unit in Group R-3 or R-5 or any Group R-2 townhouse, walls separating the dwelling units that are not continuous from the foundation to the underside of the roof sheathing shall be improved to provide a continuous fire separation using construction materials consistent with the existing wall or complying with the requirements for new structures. Work shall be performed on the side of the dwelling unit wall that is part of the work area." 4. Revise Section 903.3 by replacing "floor" with "story" and "floor of exit discharge" with "level of exit discharge." 5. Insert a new Section 903.4 to read: “903.4 Low-sloped roof edges and openings. Low-sloped roofs and openings in low-sloped roofs shall be made to comply with Section 1516 of the Chicago Building Code.” (Amend Coun. J. 2-19-20, p. 14473, Art. IV, § 18; Amend Coun. J. 10-9-24, p. 18818, § 3)

Ask a question about Chicago law

Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.