14X-5-502.3 Maintenance.
The required fire-resistance rating of fire-resistance-rated construction, including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings, sprayed fire-resistant materials applied to structural members, and fire-resistant joint systems, must be maintained. Such elements must be visually inspected annually by the owner and repaired where damaged, altered, breached, or penetrated. Records of inspections and repairs must be maintained by the owner. Where concealed, such elements are not required to be visually inspected unless the concealed space can be accessed by the removal or movement of a panel, access door, or ceiling tile or entry to the space. (Amend Coun. J. 2-19-20, p. 14473, Art. V, § 19; Amend Coun. J. 10-7-20, p. 21791, Art. V, § 6)