15-28-360 Safety clearances.
Potentially explosive chemicals buildings or outside storage areas shall have a safety clearance to any building, combustible storage in the open, flammable liquid storage, lot line or public way. Such safety clearances shall be as follows: Organic peroxides: Weight (Pounds) | Distance (Feet) 50 – 100 | 35 101 – 500 | 50 501 – 1,000 | 65 1,001 – 3,000 | 100 3,001 – 5,000 | 150 In no case shall a safety clearance of less than 500 feet be provided to any lot line of any plot of ground on which is situated a school, hospital or other institutional building, assembly or open air assembly building. (Prior code § 92-31)