For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15-28-360 — Safety clearances

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 15-28-360

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/1129fb0f-9923-4bc9-b90c-8e3a93b14f4e

15-28-360 Safety clearances.

Potentially explosive chemicals buildings or outside storage areas shall have a safety clearance to any building, combustible storage in the open, flammable liquid storage, lot line or public way. Such safety clearances shall be as follows: Organic peroxides: Weight (Pounds) | Distance (Feet) 50 – 100 | 35 101 – 500 | 50 501 – 1,000 | 65 1,001 – 3,000 | 100 3,001 – 5,000 | 150 In no case shall a safety clearance of less than 500 feet be provided to any lot line of any plot of ground on which is situated a school, hospital or other institutional building, assembly or open air assembly building. (Prior code § 92-31)

Ask a question about Chicago law

Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.