§ 15-28-620 — Fire-resistive separation
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 15-28-620
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/71f1e9b3-aa99-4898-b721-3cb4a263dbf5
15-28-620 Fire-resistive separation.
When the quantity of loose highly flammable materials stored exceeds 100 cubic feet, rooms separating such area from every other part of the building shall be required. Such rooms shall have separations providing the following fire-resistive ratings: Quantity of Highly Flammable Materials | Fire-resistive Rating 100.1 to 500 cubic feet | 1-hour 500.1 to 2,500 cubic feet | 2-hour Exceeding 2,500 cubic feet | 4-hour Baled storage rooms shall comply with the following: Quantity of Highly Flammable Materials | Fire-resistive Rating 500 to 2,500 cubic feet | 1-hour 2,500.1 to 5,000 cubic feet | 2-hour Exceeding 5,000 cubic feet | 4-hour (Prior code § 92-51)
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.