16-6-055 Site development requirements applicable to Zone VE.
In Zone VE, all development must meet the following requirements: (a) The use of fill for structural support of buildings is prohibited. (b) Non-structural fill shall be permitted only if an engineering report demonstrates that the fill will not cause runup, ramping, or deflection of floodwaters that cause damage to buildings. (c) Man-made alterations of sand dunes are prohibited unless an engineering report documents that the alterations will not increase potential flood damage by reducing the wave and flow dissipation characteristics of the sand dunes. (d) Bulkheads, seawalls, revetments, and other erosion control structures shall not be connected to the foundation or superstructure of a building and shall be designed and constructed so as not to direct floodwaters or increase flood forces or erosion impacts on the foundation or superstructure of any building. (Added Coun. J. 7-21-21, p. 33505, § 4)