§ 18-28-803.10.3 — Connection
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-28-803.10.3
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/2d9e723b-2ed2-4aff-8993-2bf06c017635
18-28-803.10.3 Connection.
The connector shall extend to the inner face of the chimney or vent liner but not beyond. A connector entering a masonry chimney shall be cemented to masonry in an approved manner. If thimbles are installed to facilitate removal of the connector from the masonry chimney, the thimble shall be permanently cemented in place with high-temperature cement.
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.
