18-29-1003.3.5.2 Rate of flow controls.
Grease interceptors shall be equipped with devices to control the rate of water flow so that the water flow does not exceed the rated flow. The flow-control device shall be vented and terminate not less than 6 inches (150 mm) above the flood rim level or installed in accordance with the manufacturer's instructions. (Amend Coun. J. 10-14-21, p. 37722, Art. X, § 3)