§ 22-2 — Electrical Code

Code of Ordinances of the Town of Cicero, Illinois (Codified through Ordinance No. 71-25, adopted September 23, 2025. (Supp. No. 122)) · Cicero Municipal Code § 22-2

Corpus is an independent public-information project, not the official City of Cicero website. Stable reference: corpuslaw.us/code/eb9a2b30-8b86-4544-9a5f-8f44bbdcef76

Sec. 22-2. - Electrical Code.

For purposes of this Section "Electrical Amendments" shall mean the additions, insertions, deletions and changes made to the NFPA 70, National Electrical Code, 2023 Edition, a copy of which is on file with the Town Clerk. The Town hereby adopts, by reference as if fully set forth in this Code, the NFPA 70, National Electrical Code, 2023 Edition, including all Annexes and regulations thereto, as adopted by the National Fire Protection Association, excepting those provisions that are modified or deleted by the Electrical Amendments and as otherwise provided in this Section. At least one copy of the NFPA 70, National Electrical Code, 2023 Edition and the Electrical Amendments are on file in the Office of the Town Clerk and are available for public use, inspection and examination. If any provision of the NFPA 70, National Electrical Code, 2023 Edition or the electrical amendments is in conflict with any provision of any code, ordinance, rule or regulation of the town, the more stringent regulation will apply; provided, however, the Cicero building Commissioner and/or the Cicero Fire Chief may waive the more stringent requirement if said waiver would be beneficial to the health, safety or welfare of the Town or its residents. The Electrical Amendments are as follows: 1. The following articles are deleted in their entirety. a. Article 398. Pertaining to open wiring in insulators, (see Attachment "L", "M" and "N"). b. Article 394. Concealed Knob-and-Tube wiring, (see Attachments "O" and "P"). c. Article 326. Integrated Gas Spacer Cable, (see Attachments "Q" and "R".) d. Article 324. Flat Conductor Cable (FT) Usually under carpets, (see Attachments "U" "V" and "W"). e. Article 362. Electrical Non-Metallic Tubing (flexible corrugated), (see Attachments "X", "Y" and "ZZ). f. Article 334. Non-Metallic Sheathed Cable/Type NM, NMC and NMS, (see Attachments "AA", "BB", "CC" and "DD"). g. Article 338. Service-entrance Cable/Type SE and USE, (see Attachments "EE" and "FF'). h. Article 382. Non-Metallic Extensions, (see Attachments "GG", "HH" and "II"). i. Article 352.10.A. Concealed. In walls, floors, and ceilings, (see Attachment "JJ"). j. Article 352.10-D. Cinders. In cinder fill, (see Attachment "JJ"). k. Article 352.10.-G. Exposed, (see Attachment "JJ"). l. Article 320.0. of the N.E.C.(see Attachments "KK", "LL" and "MM") m. Article 330. Metal-Clad Cable n. Article 335. Instrumentation Tray Cable o. Article 337. P Cable p. Article 369. Insulated Bus Pipe/Tubular Covered Conductors Systems q. Article 371. Flexible Bus Systems r. Article 393. Low-Voltage Suspended Ceiling Power Distribution Systems s. Article 395. Outdoor Overhead Conductors over 1000 Volts 2. All non-metallic raceway or cable types are prohibited and associated code articles and requirements are effectively deleted. Electrical metallic tubing, rigid conduit or intermediate metal conduit shall be used for all feeders and branch circuit wiring. Flexible metal conduit (types of FMC & LFMC) may be used in accessible locations with its cumulative length limited to 6 feet and a dedicated equipment grounding conductor. In other than accessible locations, special permission may be granted for lengths more than 6 feet on a case-by-case basis. A. Exception: Rigid Polyvinyl Chloride (PVC) conduit, as described in Article 352 of the 2023 NEC, shall be permitted for use within the Town of Cicero, provided it complies with the Town of Cicero's electrical amendments to the 2023 NEC. PVC conduit installations must be approved for the intended use. 3. Chapter 10 "Amendments" is hereby stricken in its entirety and replaced as adopted as set forth herein: a. NEW SINGLE-FAMILY RESIDENCES: The following regulations shall apply to electrical services for new single-family residences: 1. For single-family residences having a total floor area of one thousand five hundred (1,500) square feet or more, as determined by the Planning, Building and Zoning Division: i. The service entrance conduit shall be two-inch (2") trade size. No thin wall conduit shall be used. The minimum service size shall be two hundred (200) amps. ii. The service entrance conductors shall have a current carrying capacity of two hundred (200) amps and shall be equal to or better than copper, AWG size 3/0 THWN minimum size. iii. The Main Service Panel shall contain a two hundred (200) ampere main switch or breaker which will disconnect all distribution in the building. No split buss panels shall be used. Minimum thirty (30) circuit panel and a maximum forty-two (42) circuit panel. 2. For single-family residences having a total floor area less than one thousand five hundred (1500) square feet. i. The service entrance conduit shall be one and one-fourth inch (1¼″) trade size. No thin wall conduit shall be used. The minimum service size shall be one hundred (100) amps. ii. The service entrance conductors shall have a current carrying capacity of one hundred (100) amps and shall be equal to or better than copper, AWG size 3, THWN minimum size. iii. The Main Service Panel shall contain a one hundred (100) ampere main switch or breaker, which will disconnect all distribution in the building. No split buss panels shall be used. Only a minimum twenty (20) circuit panel and a maximum twenty-four (24) circuit panel shall be provided. 3. This section applies to all alterations, remodeling, or repairs to dwelling-type occupancies not exceeding four stories. When alterations, remodeling, or repairs affect more than 50% of a building structure, dwelling unit, or electrical system, the following requirements shall apply: i. The electrical system shall conform to the provisions outlined in Amendment B. ii. A load calculation shall be submitted before any electrical work is started for all electrical installations, alterations, or repairs. 4. Tandem Breakers are Prohibited. 5. A maximum of three (3) conduits per one- and one-half inch (1-1/2") 8-B or four conduits per 4"x4" square box shall be allowed. 6. Studs, plates, and joists must be drilled so as not to break the front half of the wood. If it is broken and the conduit is exposed, a metal plate must be places across the opening. 7. Jacuzzi, spa, or whirlpool tubs shall be hard wired to a J box, with a switch, or G.F.I protected receptacle where is can be plugged. No cords from motors shall protrude through a wall or the floor to be wired. All tub motors will have an access panel with a minimum size of fourteen inches (14" x 14"). 4. Revision to the 2023 NEC Article 210.8(A) & (D) as follows: a. Ground-Fault Circuit Interrupter Protection for Personnel, 210.8(A) Dwelling Units: Exception No. 5 i. 210.8 (A) Ground-Fault Circuit-Interrupter Protection Basement Receptacles Add Exception No 5: Receptacles serving sump pumps, ejector pumps, lift stations and similar pumps shall not be required to have GFCI protection provided there is only one receptacle outlet on a single yoke or device. Such receptacles shall be an individual branch circuit and clearly marked with circuit number and disconnect location. b. 210.8(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations and supplied by single-phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel. 1. Bathrooms. 2. Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use. 3. Outdoors. 4. Crawl spaces—at or below grade level. 5. Basements. 6. Kitchens—where the receptacles are installed to serve the countertop surfaces. 7. Sinks—where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink. 8. Boathouses. 9. Bathtubs or shower stalls—where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall. 10. Laundry areas. 11. Indoor damp and wet locations. c. 210.8(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase: 1. Automotive vacuum machines. 2. Drinking water coolers and bottle fill stations. 3. High-pressure spray washing machines. 4. Tire inflation machines. 5. Vending machines. 6. Dishwashers. 7. Microwave ovens. 5. Electrical Metallic Tubing (EMT). shall not be used underground, outside exposed to the weather, outside walls, on roofs exposed to permanent moisture, in concrete slab in contact with the earth or fill, where installation or afterward it will be subject to mechanical injury. Plastic, visqueen or similar materials under the tubing is considered same as earth or fill. 6. Low Voltage Wiring. Low voltage wiring for lighting circuits, TV cable controls, telephones, intercoms, communications, including signaling circuits on commercial and industrial buildings or where there are metal studs being used, may be run exposed only in accessible areas or subject to mechanical injury, or in plenums, all wiring shall be installed in conduit or approved raceway, and all such work requires a permit. 7. All electrical services shall be in rigid metal conduit, or intermediate metal conduit. 8. All underground branch-circuit and feeder conductors shall be protected against over-current by an over-current device installed at the point where the conductors receive their supply, and all sub-panels will have main breaker located at the panel. 9. All conductors shall be installed in approved metallic raceways. (Exceptions: See Article 352.10 (C), (E), (F), (H)). 10. Amendment to 2023 NEC Article 210.52(C)(2) & (3) as Follows: a. 210.52(C)(2) Island and Peninsular Countertops and Work Surfaces. At least one receptacle shall be installed at each island and peninsular countertop space with a long dimension of 600 mm (24 in.) or greater and a short dimension of 300 mm (12 in.) or greater. A peninsular countertop is measured from the connected perpendicular wall. b. 210.52(C)(3) Receptacle Outlet Location. c. Receptacle outlets shall be located in one or more of the following: 1. On or above, but not more than 500 mm (20 in.) above, a countertop or work surface. 2. In a countertop using receptacle outlet assemblies listed for use in countertops. 3. In a work surface using receptacle outlet assemblies listed for use in work surfaces or listed for use in countertops. d. Receptacle outlets rendered not readily accessible by appliances fastened in place, sinks, or range tops as covered in 210.52(C)(1), Exception No. 1, or appliances occupying assigned spaces shall not be considered as these required outlets. e. Exception: To comply with the following conditions (1) and (2), receptacle outlets shall be permitted to be mounted not more than 300 mm (12 in.) below the countertop or work surface. Receptacles mounted below a countertop or work surface in accordance with this exception shall not be located where the countertop or work surface extends more than 150 mm (6 in.) beyond its support base. 1. Construction for the physically impaired. 2. On island and peninsular countertops or work surface where the surface is flat across its entire surface (no backsplashes, dividers, etc.) and there are no means to mount a receptacle within 500 mm (20 in.) above the countertop or work surface, such as an overhead cabinet f. Informational Note No. 1: See 406.5(E) for installation of receptacles in countertops and 406.5(F) for installation of receptacles in work surfaces. See 380.10 for installation of multioutlet assemblies. g. Informational Note No. 2: See Informative Annex J and ANSI/ICC A117.1-2009, Standard on Accessible and Usable Buildings and Facilities, for additional information. 11. 2023 NEC Article 210.8(F) Outdoor Outlets: Delete in its entirety. 12. 2023 NEC Article, Interconnected Electric Power Production Sources 705.11 - Source Connections to a Service is hereby deleted in its entirety. All references to Article 705.11 in related sections of the 2023 NEC are prohibited. 13. Amendment to NEC 2023 Article 210.12(B) Exception No. 3 Arc-Fault Circuit-Interrupter Protection. a. Exception No. 3: This exception does not apply to branch circuits serving bedrooms, which shall continue to comply fully with Article 210.12, requiring AFCI protection. It shall be permitted to omit AFCI protection for that portion of a branch circuit that is entirely enclosed within one of the following wiring methods: 1. Rigid Metal Conduit (RMC). 2. Flexible Metal Conduit (FMC). 3. Intermediate Metal Conduit (IMC). 4. Electrical Metallic Tubing (EMT). 14. 2023 NEC Article 760.179(E) is hereby amended to include the new requirement for red-colored covers on raceway system boxes used for fire alarm systems. Amendment to NEC Article 760.179(E) - Identification. Wiring and equipment for fire alarm systems shall be identified and marked in accordance with 760.179(C). The covers of all junction boxes, pull boxes, and other enclosures associated with raceway systems containing fire alarm circuits shall be red in color. The red color shall be applied in a durable and permanent manner, such as by painting, powder coating, or the use of factory-finished components. This requirement ensures clear identification of fire alarm system enclosures during installation, inspection, and maintenance. 15. The use of aluminum or copper-clad aluminum conductors is prohibited. 16. Definitions: a. Authority Having Jurisdiction (AHJ): An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or a procedure. b. Electrical Contractor: Any person, firm, or corporation engaged in the business of installing or altering by contract, electrical equipment for the utilization of electricity supplied for light, heat, or power, not including apparatus, conductors, or other equipment installed for, or by, public utilities, including common carriers which are under the jurisdiction of the Illinois commerce commission for use in their operation as public utilities; but the term "electrical contractor" does not include employees employed by any person, firm, or corporation to supervise such work. c. Electrical Equipment: Conductors and equipment installed for the utilization of the electricity supplied for light, heat, or power, but does not include radio apparatus or equipment for wireless reception of sounds and signals, and does not include apparatus, conductors and other equipment installed for, or by, public utilities, including common carriers, which are under the jurisdiction of the Illinois commerce commission for use in their operation as public utilities.

(Code 1958, § 26-1; Ord. No. 9-87, § 1, 3-24-1987; Ord. No. 94-12, § 3.03, 12-11-2012; Ord. No. 12-26, § 3.01, 3-24-2026)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.