§ 22-247 — Testing of installations or alterations

Code of Ordinances of the Town of Cicero, Illinois (Codified through Ordinance No. 71-25, adopted September 23, 2025. (Supp. No. 122)) · Cicero Municipal Code § 22-247

Corpus is an independent public-information project, not the official City of Cicero website. Stable reference: corpuslaw.us/code/36f66873-1d99-4cbd-a7c9-009d778cffd2

Sec. 22-247. - Testing of installations or alterations.

(a) It shall be the duty of any person installing refrigerating systems to apply tests to the systems as required by the chief inspector of the department of steam boilers, unfired pressure vessels and cooling plants. (b) Tests shall be made in the presence of an inspector of the department of steam boilers, unfired pressure vessels and cooling plants and shall be applied to every refrigerating system or parts thereof, installed before being put into use; provided, however, that the department of steam boilers, unfired pressure vessels and cooling plants may accept from the manufacturer of a single unit system a certified copy of test report showing that tests of the system, as required by the sections of this Code pertaining to buildings, were made at the place of manufacture. (c) It shall be the duty of every person installing such refrigerating systems to notify the chief inspector of the department of steam boilers, unfired pressure vessels and cooling plants whenever any system has reached the stage of construction where it is ready for inspection tests. (d) The testing of every refrigerating system shall include a pressure or vacuum test of the complete piping system, preferably with the evaporator installed, but valves thereon may be closed to prevent withdrawal of the refrigerant. (e) Under these tests a partial vacuum of 20 inches of mercury shall be produced within the system and shall be held for a period of at least one hour with no detectable drop. (f) Every part of every refrigerating system shall be designed, constructed and assembled to withstand safely and without injury the required minimum test pressures, which shall be applied for the pressure test. These test pressures shall be held by every refrigerating system under test for a period of one hour or more without any appreciable fall.

(Ord. of 7-19-1948, § 72; Code 1958, § 28-40)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.