Sec. 26-325. - Construction and equipment specifications.

All buildings regulated by this division shall be constructed and equipped according to the following specifications: (1) Materials and size of buildings. Every such building shall be built of brick, stone or concrete, with no basement, and shall not exceed one story in height; provided, however, that the use of any building not exceeding three stories in height in which a dry cleaning business was carried on prior to February 15, 1932, may be continued if such building complies in all other respects with this division. The first floor in such building shall be higher than the surface of the ground surrounding such building and shall be so laid that there shall be no space underneath the floor. The floor of both the dry cleaning room and drying room and the ceiling or roof of the dry cleaning room shall be of fireproof construction, and the roof on the drying room, if of combustible material, shall be without concealed spaces. (2) Floor openings and stairways. There shall be no openings through the floors, except in two-story buildings, in which a stairway leading from the second floor to the first floor may be permitted if properly enclosed with walls of incombustible material. Such stairway shall lead to the outside of the building without any doors or openings leading into the dry cleaning room. (3) Location. Every such building shall be detached and at least 50 feet from any other building or structure or to the line of adjoining property which may be built upon. However, the use of any building in which a dry cleaning business was carried on prior to February 15, 1932, may be continued where such building is separated from all other buildings by a firewall, with no openings into any adjoining building, and any building previously used for dry cleaning but not so occupied or used for such purposes for a period of three consecutive months immediately prior to February 15, 1932, shall not again be used for the business of dry cleaning unless there is compliance with all requirements governing new buildings or dry cleaning plants. (4) Use. A building used for dry cleaning or spotting shall not be occupied for any purpose other than the conducting of a dry cleaning and dry room plant. The walls of such building shall not be less than 12 inches thick and shall have vent holes at the floor line not less than 16 square inches in area, when ventilation by means of an exhaust fan is employed, and not less than 32 square inches in area when ventilation by means of a paddle-wheel type fan is employed. Such vent holes shall not be more than six feet apart, measured from center to center, and shall be protected by screens of 30 mesh brass wire on the inside of such walls and by iron bars or screens of large mesh on the outside of such walls. (5) Ventilation. Such building, unless divided into compartments, as described in this subsection, shall be further ventilated by means of an exhaust fan of sufficient capacity to change the air in the building every three minutes, and the exhaust fan shall be kept in operation at all times during the use of such building. Such exhaust fan shall be located in an air conduit whose inlet openings shall be at or near the floor level in the wall farthest away from any other building or structure, and the discharge end of such conduit shall be carried above the roof of such building. If such building is divided into fireproof compartments, by partitions of six-inch hollow tile or equivalent, extending from floor to ceiling, each such compartment having a capacity of not to exceed 2,500 cubic feet, the exhaust fan and air conduit may be omitted from each of such compartments and in lieu thereof there shall be a paddle-wheel type fan attached to the line shafting in each compartment of sufficient size to displace an amount of air equal to the cubical contents of the compartment at least once each minute. All doors in any such building shall be constructed of incombustible materials and shall open outward. All window openings of such building shall be protected by fire resisting glass with metal sashes and frames or by outside iron shutters. (6) Stairways in two-story buildings. Every such building two stories high shall be provided with two stairways leading from the second to the first floor, at least one of which must be placed on the outside and constructed of iron or steel. (7) Fire prevention equipment. Every such dry cleaning plant shall be equipped with a high-pressure steam boiler of a capacity equivalent to one horsepower for each 100-cubic foot contents of the dry cleaning or benzine room to allow flooding the dry cleaning and dry rooms with steam if a fire occurs. A steam pressure of at least 30 pounds must be maintained in the boiler at all times while the plant is in operation. Each room of such building shall be equipped with a line of 1¼-inch pipe connected with a 1¼-inch supply line leading from such high-pressure boiler and having downspouts of at least two inches in length and not less than ten feet apart distributed over washers and extractors. The valve operating such lines of pipe shall in every case be placed outside of such building; provided, however, that every such dry cleaning plant constructed and maintained prior to February 15, 1932, may, in place of such high-pressure boiler, be equipped with such adequate and practical fire extinguishing system as may be approved by the fire marshal. (8) Steam power. Whenever steam power shall be used for the operation of any machinery contained in any such dry cleaning establishment, the boiler generating such power shall be located in a separate building and shall be so situated that the line of travel for gasses between the boiler and the nearest opening into the cleaning or drying room shall be not less than 20 feet. Whenever electrical power is used, the electric motor furnishing such power shall be similarly located. (9) Lighting. Every such building shall be lighted by incandescent electric lamps having keyless sockets, protected by vaportight outer globes and controlled by outside switches. No open light or flame of any kind whatsoever shall be allowed or used therein. (10) Water tank. Every such establishment shall be provided with an open tank not less than four feet long, two feet wide and three feet deep, which shall be placed near the entrance to the dry cleaning room and shall be kept filled with water. (11) Asbestos blanket. Every such establishment shall be equipped with an asbestos blanket of a size not less than six feet by nine feet. Such blanket shall be placed inside the dry cleaning or benzine room near the door and in such a position that it shall be easily accessible for use if a fire occurs.

(Ord. of 2-15-1932, § 4; Code 1958, § 14-8)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.