Sec. 98-59. - Requirements for installation of water saving plumbing fixtures.

(a) Flow rates or water usage. In all new construction and in all repair and/or replacement of fixtures or trim, only fixtures and trim not exceeding the following flow rates and/or water usage shall be installed; these ratings are based on a pressure at the fixture of 40 to 50 psi: (1) Water closets, tank type, 3.5 gallons per flush. (2) Water closets, flushometer type, 3.0 gallons per flush. (3) Urinals, tank type, 3.0 gallons per flush. (4) Urinals, flushometer type, 3.0 gallons per flush. (5) Shower heads, 3.0 gallons per minute. (6) Lavatory, sink faucets, 3.0 gallons per minute. (b) Lavatories for public use. In addition to the requirements of subsection (a) of this section, all new construction and replacement fixtures, faucets or lavatories located in restrooms intended for public use shall be of metering or self-closing type. (c) Carwash installation. In all new construction and replacement of fixtures in carwashes, the installation shall be equipped with a water recycling system. (d) Use of potable water. Potable water shall not be used for the flushing of sanitary sewers. (e) Closed system air conditioning and refrigeration systems. Closed system air conditioning and refrigeration systems shall be equipped as follows: (1) No consumer shall install, remodel, or add to any air conditioning system or refrigerating system which uses water from the public supply without first having procured a written permit therefor from the building commissioner. All consumers are required to give notice of completion of the installation. This subsection shall not apply to systems with a total rated capacity of less than two tons per 24 hours. (2) All consumers who have installed air conditioning system and refrigerating system equipment which uses water from the public supply, in lieu of a permit, shall notify the building commissioner of such existing installation. (3) No water from the public supply shall be used by any new, remodeled, or addition to an air conditioning system or refrigerating system having a total rated capacity of greater than two tons per 24 hours, unless such air conditioning system or refrigerating system is a closed unit equipped with evaporative condensers, cooling towers, spray ponds, or other water-cooling equipment and water conservation devices.

(Code 1958, § 37-35.1; Ord. No. 39-77, 10-25-1977; Ord. No. 8-83, 8-23-1983)

Ask a question about Cicero law

Corpus searches the Cicero sections it holds and shows the ones that match, with their citations. Free, no sign-in.