14.04.210. - Sprinkler and fire protection service.
A. Whenever sprinkler or fire protection services are desired, application must be made for the privilege of installing such service. Complete plans for such installation shall be attached to such petition. When the application is approved, a contract shall be entered into with the water department for connection from city mains to the property line, which connection will be made by the department, the cost of the same to be paid by the petitioner before installation is completed. B. City water will not be turned into any sprinkler or fire protection service unless all pipes in connection with such system are left exposed for inspection until a pressure test is made. Water shall not be turned on in such service until costs of such installation are paid in full. The water department shall require meters for such services. A valve shall be installed with a rising stem on each side of the check valve. C. No additional sprinkler heads shall be installed, or new connection of any kind whatsoever shall be made to a sprinkler or fire protection system unless a permit for such connection has been granted by the water department. D. Every fire protection and sprinkler service system shall be equipped with a cross connection control device as follows: Pipe Size (inches) | Device Required With No Chemicals | Device Required With Chemicals Up to 2 | Double check valve (DCV) | Reduced pressure zone (RPZ) 2.5 or larger | Double detector check valve (DDCV) 1 | Detector reduced pressure zone (DRPZ) 1 Note: 1. Meter to read in cubic feet. The cross connection control device shall have inspection and tests made by a certified cross connection control device inspector, of such approved devices as required by the Illinois Plumbing Code and section 14.04.065. E. Any service location requiring on site fire protection, including, but not limited to, an interior fire suppression sprinkler system or an on-site fire hydrant, shall install a dedicated service pipe that is independently connected to the city's water distribution system for the on-site fire protection system at the service location. Water supplied for domestic use on any such premises shall be provided with an independent service pipe with a dedicated shut-off box. F. A customer shall be charged the water service installation rate, as provided in this chapter, for any domestic water service tap or fire suppression system tap that is installed by the city. G. When the water main is located on the opposite side of the street in which the building or facility to be serviced by a dedicated service pipe for an on-site fire protection system, the water director may permit a domestic service pipe to be connected to the dedicated service pipe for an on-site fire protection system, provided the individual taps and curb stop is located at the property line of the building or facility being serviced.
(Ord. No. G13-12, 2012; Code 1976, § 14.04.210)
Ask a question about Elgin law
Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.