16.20.060. - State of Illinois Plumbing Code amendments.
The following provisions of the State of Illinois Plumbing Code shall be amended and revised as follows: Section 890.320 Type of Joints shall be amended to read as follows: Subsection (k) Bituminized Fiber Pipe Joints, is deleted in its entirety. Subsection (l)(2) Joints and Fittings in Plastic Pipe for potable water service, is amended as follows: Subsections (l)(2)(A), (l)(2)(B) and (l)(2)(C), inclusive, are deleted in their entirety. Section 890.340 Use of Joints, subsection (h), shall be amended to read as follows: Building Sewer Connections. An elastomeric coupling seal conforming to ASTM C 425 (1988), ASTM C 443 (1985), ASTM C 564 (1988), ASTM D 4161 (1986), ASTM F 477 (1985), or ASTM D 3139 (1989), ASTM D 3212 (1989), or ASTM D 412 (1980) tests may be used to adapt any two (2) building sewer pipes for different materials or size changes. The flexible couplings shall be attached to the pipe with stainless steel clamps or bolts. All coupling shall be of the no-shear type for repairs to existing sewers. The manufacturer's recommended method of installation shall be followed. Section 890.420 Pipe Cleanouts, subsection (a)(4) shall be amended to read as follows: A full size cleanout shall be located within five (5) feet of the building foundation, inside and outside in direct line with the building drain and sewer. The outside cleanout shall terminate level with finished grade. In new, multi-story commercial buildings, cleanouts shall extend up to and be accessible from the floor level of the plumbing fixtures they are serving. Section 890.510 Grease Interceptor Requirements, subsection (a)(3) shall be amended to read as follows: No grease interceptor shall receive the discharge from a food waste disposal or a commercial dishwashing machine. Section 890.630 Installation, shall be amended to add subsection (j) to read as follows: Plumbing fixtures or faucets attached to a wall or protruding through a wall shall be made watertight by either caulking or a factory supplied gasket where they contact a wall surface. Section 890.1110 Quality of Water Supply, shall be amended to add subsection (a) to read as follows: a) Backflow protection required by the City of Elgin: 1) In all new commercial and industrial construction, each domestic water service shall have a Reduced Pressure Principle Backflow Preventer Assembly (RPZ) installed directly after the city water meter and on the meter by-pass (if by-pass is required). 2) On any remodeling of a commercial or industrial building where a plumbing permit is required, each domestic water service shall have a Reduced Pressure Backflow Preventer Assembly (RPZ) installed directly after the city water meter and on the meter by-pass (if by-pass is required). 3) Businesses dispensing food or beverages will be required to have a Dual Check Valve (DuC) on each piece of equipment that is supplied with water if that equipment does not have a proper air gap per the State of Illinois Plumbing Code. 4) All residential boilers will be required to have a Dual Check Valve (DuC) at its point of connection to the domestic water supply. 5) Commercial and industrial boilers, heat exchangers and cooling towers will be required to have a Reduced Pressure Principle Backflow Preventer Assembly (RPZ) at their point of connection to the domestic water supply. 6) All manufacturing equipment installed to the domestic water supply will be required to be inspected to see if backflow protection is required either by city ordinance, EPA regulations or the State of Illinois Plumbing Code. Section 890.1190 Water Supply Control Valves and Meter, subsection (a) shall be amended to read as follows: A full-port shut-off valve shall be located near the curb or property line. Section 890.1190 Water Supply Control Valves and Meter, subsection (b) shall be amended to read as follows: The utility meter must be installed inside the building, with the exception of landscaping systems. Full Port Ball Valves shall be installed on the inlet and outlet side of the water meter. All meters shall be provided with a drip valve installed between the meter discharge and the shut-off valve. All meters three inches (3") and larger will be required to have a by-pass, at least fifty percent (50%) the size of the meter, installed around the meter with a locking type ball valve installed on it. The locking valve will be on the inlet side of any devices installed on the by-pass. If a RPZ is required on the building service the by-pass will tie back in on the building side of the RPZ and will have a RPZ installed on the by-pass. All meter installations of 3 inch and larger shall be required to install a mega lug flange on the outlet side of the meter for meter serviceability. Section 890.1200 Water Service Sizing, subsection (a), shall be amended to read as follows: Water Service Pipe Sizing. The water service pipe from the street main (including the tap) to the water distribution system for the building shall be sized in accordance with Appendix A, Tables M, N, O, P and Q. Water service pipe and fittings shall be at least one (1) inch nominal diameter I.D. Type K copper. If flushometers or other devices requiring a high rate of water flow are used, the water service pipe shall be designed and installed to provide this additional flow. Section 890.1200 Water Service Sizing, shall be amended to add subsection (d) to read as follows: d) Separate Water Services. 1) Separate water services shall be required from the street main for each residential unit that will be separately metered. 2) Any services run through a porch box must be either sleeved with ductile iron sealed (watertight) sleeve or the porch box backfilled with washed gravel. Section 890.1220 Hot Water Supply and Distribution, shall be amended to add subsection (a)(.01), to precede subsection (a)(1) and to read as follows: Rigid piping is required on the water inlet and discharge piping from at water heater. Additionally, the gas supply piping at the water heater is required to be rigid piping. Flexible pipe connections for both water as well as gas piping are prohibited Section 890.1220 Hot Water Supply and Distribution, shall be amended to add subsection (a)(.02), to precede subsection (a)(1) and to read as follows: Any water heater with an input rating greater than 50,000 BTU will require a properly sized and approved expansion tank located in the water heater's cold water supply, with no shut-off valve between the heater and expansion tank. Section 890.1220(a)(9)(A) Point-of-Use Water Heaters, shall be amended to read as follows: Non-storage and non-pressurized units intended to deliver water temperatures exceeding 110 degrees Fahrenheit, or with no mechanical or electrical temperature limiting device, shall have the faucet located at least 3 inches from the 110 degrees Fahrenheit hot water or cold water faucet. Faucet outlets shall have labels clearly and conspicuously indicating extremely hot water. Section 890.1360 Sanitary Wastes Below Sewer, subsection (a) shall be amended to read as follows: Sanitary wastes which cannot be discharged by gravity flow shall be discharged into a gas-tight, covered and vented sump from which the waste shall be lifted and discharged into a sanitary waste drain by automatic pumping equipment. The discharge from all plumbing fixtures and floor drains below the rim elevation of the nearest downstream manhole shall be lifted and discharged by automatic pumping equipment into the sanitary waste. Section 890.1360 Sanitary Wastes Below Sewer, subsection (b) shall be amended to read as follows: Design. Sump and pumping equipment shall be designed and installed to discharge, during the pumping cycle, all contents accumulated in the sump except for sump contents that must remain in the sump for the continued proper operation of the pumping equipment (e.g., contents needed to submerge or prime the pump) according to the manufacturer's recommendations. Sump pits shall be a minimum of eighteen (18) inches in diameter and a minimum of thirty (30) inches in depth. An ejector pump with a minimum two (2) inch discharge shall be installed in all pits discharging into the sanitary system. Section 890.1360 Sanitary Wastes Below Sewer, subsection (e) shall be amended to read as follows: Vent Sizes. Building sump vents shall be sized in accordance with Appendix A: Table K, but shall be a minimum of two (2") inches. Section 890.1380 Storm Water Drainage Within a Building, shall be amended to read as follows: Any piping installed within a building for the purpose of carrying storm water from a roof and connected to a building drain or building sewer shall comply with the requirements of Appendix A. Table A (Approved Building Drainage/Vent Pipe) and Sections 890.910 through 890.930, as well as Chapter 16.22 of the Elgin Municipal Code, 1976, as amended, entitled "Storm Drainage Code". Section 890.1420 Stack Vents, Vent Stacks, Main Vents, shall be amended to add subsection (d), to read as follows: d) Building Sump Vent Sizes. Building Sub-drain Sump Vent Sizes shall be sized in accordance with Appendix A: Table K, but shall be a minimum of two inches (2"). Section 890.1430 Vent Terminals, subsection (g), shall be amended to read as follows: Vent Terminal Size. Each vent extension through the roof shall be a minimum of four inches (4") in diameter and no smaller than the vent in which it terminates. Vent terminals shall not be screened. Section 890 Appendix A - Plumbing Materials, Equipment, Use Restrictions and Applicable Standards, shall be amended as follows: Table A - Approved Building Drainage/Vent Pipe, the following items shall be deleted in their entirety: 1) Acrylonitrite Butadiene Styrene (ABS) Pipe Table A - Approved Building Drainage/Vent Pipe, Agency Notes, the following agency note shall be amended to read as follows: Agency Note 4: PVC pipe with cellular core is approved only for gravity drainage and venting above ground. It is not approved for pressurized drain, waste or venting applications. Table A - Approved Materials for Building Sewer, the following items shall be deleted in their entirety: 2) Asbestos Cement Pipe 5) Concrete Pipe Table A - Approved Materials for Water Service Pipe, the following items shall be deleted in their entirety: 1) Acrylonitrite Butadiene Styrene (ABS) Pipe 2) Brass Pipe 4) Chlorinated Polyvinyl Chloride (CPVC) Pipe 7) Galvanized Steel Pipe 8) Poly Butylene (PB) Pipe 9) Polyethylene (PE) Pipe 10) Polyethylene (PE) Tubing 11) Polypropylene Pipe 12) Polyvinyl Chloride (PVC) Pipe Table A - Approved Materials for Water Distribution Pipe, the following items shall be deleted in their entirety: 2) Chlorinated Polyvinyl Chloride (CPVC) Pipe 5) Cross Linked Polyethylene 7) Poly Butylene (PB) Pipe/Tubing 8) Polypropylene Pipe 9) Polyvinyl Chloride (PVC) Pipe Table A - Approved Materials for Water Distribution Pipe, subsection (4) shall be amended to read as follows: 4) Copper/Copper Alloy Tubing 2 , ASTM B 88-2009 (Commercial applications shall be required to use Type L or K copper tubing. Type M copper tubing shall not be used in commercial applications.) Table A - Approved Materials for Water Distribution Pipe, item (11) shall be amended to read as follows: 11) Welded Copper Water Tube 2 , ASTM B447-2012a Type WK, WL and WM. (Type WM shall be used in residential only.) Table A - Approved Materials and Standards for Plumbing Fixtures and Fixture Fittings, the following item should be amended as follows: 5) Fittings: Plumbing Fixture Fittings (Water stop valve bodies shall be constructed of brass, stainless steel, or other metallic material as approved by the Building Official).
(Ord. No. G17-25, § 2, 3-26-2025)
Ask a question about Elgin law
Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.