16.21.030. - Additions, insertions, and changes.

Chapter 11 and Appendix B of the International Plumbing Code 2021 are amended and revised in the following respects: Section 1101.4 Tests, shall be amended to read as follows: The conductors and the building storm drain shall be tested in accordance with Sections 890.1920 and 890.1930 of the State of Illinois Plumbing Code, as adopted by Chapter 16.20 of the Elgin Municipal Code. Section 1101.6 Fittings and connections, shall be amended to read as follows: All connections and changes in direction of the storm drainage system shall be made with approved drainage-type fittings in accordance with Sections 890.1320 (i), 890.1320 (j) and 890.1320 (k) of the State of Illinois Plumbing Code, as adopted by Chapter 16.20 of the Elgin Municipal Code. The fittings shall not obstruct or retard flow in the system. Section 1101.8 Cleanouts required, shall be amended to read as follows: Cleanouts shall be installed in the storm drainage system and shall comply with the provisions of Section 890.420 of the State of Illinois Plumbing Code, as adopted and amended by Chapter 16.20 of the Elgin Municipal Code, for sanitary drainage pipe cleanouts. Section 1101.9 Backwater valves, shall be amended to read as follows: Storm drainage systems shall be provided with backwater valves as required for sanitary drainage systems in accordance with Section 890.1320(o) of the State of Illinois Plumbing Code, as adopted by Chapter 16.20 of the Elgin Municipal Code. Section 1102.2 Inside storm drainage conductors, shall be amended to read as follows: Inside storm drainage conductors installed above ground shall conform to one of the standards listed in Appendix A, Table A, Approved Building Drainage/Vent Pipe (amended) of the State of Illinois Plumbing Code, as adopted and amended by Chapter 16.20 of the Elgin Municipal Code. Section 1102.3 Underground building storm drain pipe, shall be amended to read as follows: Under-ground building storm drain pipe shall conform to one of the standards listed in Appendix A, Table A, Approved Building Drainage/Vent Pipe (amended) of the State of Illinois Plumbing Code, as adopted and amended by Chapter 16.20 of the Elgin Municipal Code. Section 1102.4 Building storm sewer pipe, shall be amended to read as follows: Building storm sewer pipe shall conform to one of the standards listed in Appendix A, Table A, Approved Building Drainage/Vent Pipe (amended) of the State of Illinois Plumbing Code, as adopted and amended by Chapter 16.20 of the Elgin Municipal Code. Section 1102.7 Fittings, shall be amended to read as follows: Pipe fittings shall be approved for installation with the pipe material installed, and shall conform to the respective pipe standards or one of the standards listed in Appendix A, Table A, Approved Building Drainage/Vent Pipe (amended) of the State of Illinois Plumbing Code, as adopted and amended by Chapter 16.20 of the Elgin Municipal Code. The fittings shall not have ledges, shoulders, or reductions capable of retarding or obstructing flow in the piping. Threaded drainage pipe fittings shall be of the recessed drainage type. Section 1113.1.2 Sump Pits, shall be amended to read as follows: The sump pits shall not be less than 18 inches in diameter and 30 inches deep, unless otherwise approved. The pit shall be accessible and located such that all drainage flows into the pit by gravity. The sump pit shall be constructed of tile, steel, plastic, cast iron, concrete or other approved material, with a removal cover adequate to support anticipated loads in the area of use. The pit floor shall be solid and provide permanent support for the pump (see Section 890.Appendix J, Illustration K of the State of Illinois Plumbing Code, as adopted by Chapter 16.20 of the Elgin Municipal Code, for piping layout). 1) A 1" air gap is required for sump pump discharge into storm sewers. 2) Sump pits (sub soil storm water drainage) are required to be vented with a 2" minimum sized vent connecting to the radon reduction system. 3) All horizontal runs of the primary storm drainage piping above grade, including drain heads and roof pans, shall be insulated with ½" fiberglass insulation.

(Ord. No. G11-25, § 2, 3-26-2025)

Ask a question about Elgin law

Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.