§ 16.40.210 — Roof openings; construction
Code of Ordinances of the City of Elgin, Illinois (Codified through Ordinance No. G18-26, enacted May 27, 2026 (Supp. No. 8)) · Elgin Code of Ordinances § 16.40.210
Corpus is an independent public-information project, not the official City of Elgin website. Stable reference: corpuslaw.us/code/86046a8a-0bf3-47ce-bbe6-1f5b8541ba92
16.40.210. - Roof openings; construction.
A. Skylights and other roof openings in businesses designated as prime targets for reason of inventories. 1. Skylights. a. Skylight units or portions of openings utilizing transparent panels shall be provided with burglary-resistant glazing material, meeting or surpassing Underwriters' Laboratories Test 972. The skylight unit shall be securely fastened to the roof in such a manner as to prevent removal from the exterior using common tools; b. Iron bars of at least one-half (½) inch round or one (1) inch by one-fourth (¼) inch flat material, constructed in such a way as to allow openings no larger than eight (8) inches by twelve (12) inches, securely fastened in the well of the skylight opening; or c. A steel grille of at least ten (10) gauge material of two (2) inch mesh under the skylight and securely fastened in the well. 2. Hatchway and ventilating openings. a. All hatchway openings shall be secured as follows: (1) If the hatchway is constructed of wooden material, it shall be covered on the exterior with sheet steel of at least sixteen (16) gauge or its equivalent, attached with either vandal-proof screws or smooth-headed bolts. (2) The hatchway shall be secured from the interior with a slide bar or slide bolts. The use of crossbars or padlocks must be approved by the building official and must not violate any provision or code dealing with life safety. (3) Outside hinges on all hatchway openings shall be provided with nonremovable pins and secured with vandal-proof screws or smooth-headed bolts. (4) All hatchways shall conform to the above unless specific hatchways are called for in regards to fire codes or life safety regulations concerning spring-loaded thermostatically controlled units. b. Ventilating openings shall be secured as follows: (1) Openings in buildings, which openings are larger than ninety-six (96) square inches utilized for the intake or exhaust of air shall be securely fastened to the roof so as to prevent easy removal from the exterior using common tools; or (2) The provisions of the above in this section shall apply. B. Skylights and roof openings in buildings and businesses not specifically designated as prime targets for reasons of inventories. 1. Skylights. Skylights in buildings, not having specific high-risk inventories, will not be required to provide burglary-resistant glazing material, nor iron bars or mesh material in the wells; however, skylights must be securely fastened to the roof so as to prevent easy removal from the exterior using common tools. 2. Hatchways and ventilating openings. The same provisions apply in this section as are applicable in skylight, hatchway and ventilating openings.
(Prior Code, § 19.2103.2; Code 1976, § 16.40.210; Ord. No. G28-75, § 1, 1975)
Ask a question about Elgin law
Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.
