For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.30.135 — Site design

Code of Ordinances of the City of Elgin, Illinois (Codified through Ordinance No. G18-26, enacted May 27, 2026 (Supp. No. 8)) · Elgin Code of Ordinances § 19.30.135

Corpus is an independent public-information project, not the official City of Elgin website. Stable reference: corpuslaw.us/code/b435ed44-bac7-4ec4-a64b-d11d77356c65

19.30.135. - Site design.

In the CF Community Facility District, the use and development of land and structures shall be subject to the provisions of chapter 19.12. In the CF Community Facility District, the site design regulations shall be as follows: A. Zoning lots; generally. In the CF zoning district, zoning lots [SR] shall be subject to the provisions of section 19.12.300. B. Lot area. In the CF zoning district, the minimum required zoning lot area [SR] shall be twenty thousand (20,000) square feet. C. Lot width. In the CF zoning district, the minimum required lot width [SR] for a zoning lot shall be one hundred twenty-five (125) linear feet. D. Setbacks; generally. In the CF zoning district, setbacks [SR] shall be subject to the provisions of section 19.12.400. E. Setbacks by lot line. In the CF zoning district, the minimum required building [SR] setbacks and vehicle use area setbacks [SR] for a zoning lot shall be as follows: 1. Building setbacks. a. Street setback. The minimum required building setback from a street lot line [SR] shall be calculated as follows: Street setback (StS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus twenty thousand (20,000) square feet; the difference times 0.000019428; the product, plus twenty-five (25) linear feet. Minimum street setback can be expressed by the following formula: StS = [(ZLA—20,000) x 0.000019428] + 25 b. Interior setback. The minimum required building setback from an interior lot line [SR] shall be calculated as follows: Interior setback (IS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus twenty thousand (20,000) square feet; the difference times 0.000015542; the product, plus five (5) linear feet. Minimum interior setback can be expressed by the following formula: IS = [(ZLA—20,000) x 0.000015542] + 5 c. Transition setback. The minimum required building setback from a transition lot line [SR] shall be calculated as follows: Transition setback (TS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus twenty thousand (20,000) square feet; the difference times 0.000038856; the product, plus fifty (50) linear feet. Minimum transition setback can be expressed by the following formula: TS = [(ZLA—20,000) x 0.000038856] + 50 2. Vehicle use area setbacks. a. Street setback. For zoning lots with a vehicle use area [SR], the minimum required vehicle use area setback from a street lot line shall be calculated as follows: Vehicle use area street setback (VUAStS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus twenty thousand (20,000) square feet; the difference times 0.000013211; the product, plus eight (8) linear feet. Minimum vehicle use area setback can be expressed by the following formula: VUAStS = [(ZLA—20,000) x 0.000013211] + 8 b. Interior setback. For zoning lots with a vehicle use area, the minimum required vehicle use area setback from an interior lot line shall be six (6) linear feet. F. Accessory structures and buildings. In the CF zoning district, accessory structures and buildings [SR] shall be subject to the provisions of section 19.12.500. G. Yards; generally. In the CF zoning district, a street yard [SR], a side yard [SR], or a rear yard [SR] or a transition landscape yard [SR] established by a required building setback or by the actual location of a building shall be subject to the provisions of section 19.12.600. H. Landscape yards. In the CF zoning district, landscape yards shall be as follows: 1. Transition landscape yards. A transition landscape yard [SR] shall be provided adjoining the entire length of a transition lot line. Transition landscape yards shall be subject to the provisions of section 19.12.700. The depth of the transition landscape yard shall be one-half (½) of the required transition setback calculated in subsection E.1.c of this section. 2. Vehicle use area landscape yards. The yards established by vehicle use area setbacks from a street lot line and from an interior lot line shall be used as vehicle use area landscape yards [SR] with the exception of access driveways as provided in sections 19.45.110 and 19.45.120. Vehicle use area landscape yards shall be subject to the provisions of section 19.12.700. 3. Interior landscape yards. Interior landscape yards [SR] shall be installed on a zoning lot featuring a vehicle use area [SR], which exceeds five thousand (5,000) square feet in area, subject to the provisions of section 19.12.700. I. Floor area. In the CF zoning district, the maximum floor area [SR] for a zoning lot shall be calculated as follows: Floor area (FA) in square feet shall equal the area of a zoning lot (ZLA) in square feet minus twenty thousand (20,000) square feet; the difference times 0.4985; the product, plus twelve thousand (12,000) square feet. Maximum floor area can be expressed by the following formula: FA = [(ZLA—20,000) x 0.4985] + 12,000 J. Building coverage. In the CF zoning district, the maximum building coverage [SR] for a zoning lot shall be calculated as follows: Building coverage (BC) in square feet shall equal the area of a zoning lot (ZLA) in square feet minus twenty thousand (20,000) square feet; the difference times 0.4016; the product, plus six thousand (6,000) square feet. Maximum building coverage can be expressed by the following formula: BC = [(ZLA—20,000) x 0.4016] + 6,000

(Ord. No. G66-94, § 1, 1994; Ord. No. G45-92, § 2, 1992; Code 1976, § 19.30.135)

Ask a question about Elgin law

Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.