For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.40.335 — Site design

Code of Ordinances of the City of Elgin, Illinois (Codified through Ordinance No. G18-26, enacted May 27, 2026 (Supp. No. 8)) · Elgin Code of Ordinances § 19.40.335

Corpus is an independent public-information project, not the official City of Elgin website. Stable reference: corpuslaw.us/code/0012e047-0860-43fd-a75a-ab8e6616846b

19.40.335. - Site design.

In the GI General Industrial District, the use and development of land and structures shall be subject to the provisions of chapter 19.12. In the GI Zoning District, the site design regulations shall be as follows: A. Zoning lots; generally. In the GI zoning district, zoning lots [SR] shall be subject to the provisions of section 19.12.300. B. Lot area. In the GI zoning district, the minimum required zoning lot area [SR] shall be as follows: 1. Limited access street. Where a zoning lot has frontage on a limited access street [SR], the minimum required lot area shall be eighty thousand (80,000) square feet. 2. Arterial street. Where a zoning lot has frontage on an arterial street [SR], the minimum required lot area shall be sixty thousand (60,000) square feet. 3. Collector street. Where a zoning lot has frontage on a major collector street [SR], a collector street [SR], or a local street [SR], the minimum required lot area shall be forty thousand (40,000) square feet. C. Lot width. In the GI district, the minimum required lot width for a zoning lot shall be as follows: 1. Limited access street. Where a zoning lot has frontage on a limited access street [SR], the minimum required lot width shall be two hundred (200) linear feet. 2. Arterial street. Where a zoning lot has frontage on an arterial street [SR], the minimum required lot width shall be one hundred sixty (160) linear feet. 3. Collector street/local street. Where a zoning lot has frontage on a major collector street, a collector street or a local street, the minimum required lot width shall be one hundred twenty-five (125) linear feet. D. Setbacks; generally. In the GI district, setbacks [SR] shall be subject to the provisions of section 19.12.400. E. Setbacks by lot line. In the GI district, the minimum required building [SR] setbacks [SR] and vehicle use area setbacks [SR] from a lot line [SR] for a zoning lot shall be as follows: 1. Building setbacks. a. Street setback. Street setbacks shall be as follows: (1) Limited access street/arterial street. Where a zoning lot has frontage on a limited access street or on an arterial street, the minimum required building setback from a street lot line [SR] shall be fifty (50) linear feet, or the street setback shall be as required in subsection E.1.a(4) of this section, whichever is greater. (2) Collector street. Where a zoning lot has frontage on a major collector street or on a collector street, the minimum required building setback from a street lot line shall be thirty-five (35) linear feet, or the street setback shall be as required in subsection E.1.a(4) of this section, whichever is greater. (3) Local street. Where a zoning lot has frontage on a local street, the minimum required building setback from a street lot line shall be twenty-five (25) linear feet, or the street setback shall be as required in subsection E.1.a(4) of this section, whichever is greater. (4) Street setback exception. The minimum required building setback from a street lot line shall be subject to the street setback required in this section, where the minimum required building setback from a street lot line for a limited access street, an arterial street, a major collector street, a collector street, or a local street is less than required by the following calculation: Street setback (StS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus forty thousand (40,000) square feet; the difference times 0.000010658; the product, plus twenty-five (25) linear feet. Minimum street setback can be expressed by the following site capacity formula [SR]: StS = [(ZLA—40,000) x 0.000010658] + 25 b. Interior setback. The minimum required building setback from an interior lot line [SR] shall be calculated as follows: Interior setback (IS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus forty thousand (40,000) square feet; the difference times 0.000004633; the product, plus twenty (20) linear feet. Minimum interior setback can be expressed by the following site capacity formula [SR]: IS = [(ZLA—40,000) x 0.000004633) + 20 c. Transition setback. The minimum required building setback from a transition lot line [SR] shall be calculated as follows: Transition setback (TS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus forty thousand (40,000) square feet; the difference times 0.000023169; the product, plus one hundred (100) linear feet. Minimum transition setback can be expressed by the following site capacity formula [SR]: TS = [(ZLA—40,000) x 0.000023169] + 100 Additionally, for each linear foot of building height [SR] over twenty (20) linear feet, two (2) linear feet shall be added to the minimum required building setback from a transitional lot line. 2. Vehicle use area setbacks by lot line. In the GI district, the minimum required vehicle use area setbacks [SR] for a zoning lot shall be as follows: a. Street setback. For zoning lots with a vehicle use area [SR], the minimum required vehicle use area setback from a street lot line shall be calculated as follows: Vehicle use area street setback (VUAStS) in linear feet shall equal the area of a zoning lot (ZLA) minus forty thousand (40,000) square feet; the difference times 0.000003475; the product, plus fifteen (15) linear feet. Minimum vehicle use area street setback can be expressed by the following site capacity formula [SR]: VUAStS = [(ZLA—40,000) x .000003475] + 15 b. Interior setback. For zoning lots with a vehicle use area, the minimum required vehicle use area setback from an interior lot line shall be calculated as follows: Vehicle use area interior setback (VUAIS) in linear feet shall equal the area of a zoning lot (ZLA) in square feet minus forty thousand (40,000) square feet; the difference times 0.000004402; the product, plus six (6) linear feet. Minimum vehicle use area interior setback can be expressed by the following site capacity formula [SR]: VUAIS = [(ZLA—40,000) x 0.000004402] + 6 F. Accessory structures and buildings. In the GI district, accessory structures and buildings [SR] shall be subject to the provisions of section 19.12.500. G. Yards; generally. In the GI district, a street yard [SR], a side yard [SR], a rear yard [SR], or a transition yard [SR] established by a required building setback or by the actual location of a building shall be subject to the provisions of section 19.12.600. H. Landscape yards. In the GI district, landscape yards shall be as follows: 1. Transition landscape yards. A transition landscape yard [SR] shall be provided adjoining the entire length of a transition lot line. Transition landscape yards shall be subject to the provisions of section 19.12.700. The depth of the transition landscape yard shall be one-half (½) of the required transition setback calculated in subsection E.1.c of this section. 2. Vehicle use area landscape yards. The yards established by vehicle use area setbacks shall be used as vehicle use area landscape yards [SR] with the exception of access driveways as provided in sections 19.45.110 and 19.45.120. Vehicle use area landscape yards shall be subject to the provisions of section 19.12.700. 3. Interior landscape yards. Interior landscape yards [SR] shall be installed on a zoning lot featuring a vehicle use area [SR], which exceeds five thousand (5,000) square feet in area, subject to the provisions of section 19.12.700. I. Floor area. In the GI District, the maximum floor area for a zoning lot shall be calculated as follows: Floor area (FA) in square feet shall equal the area of a zoning lot (ZLA) in square feet minus forty thousand (40,000) square feet; the difference times 0.5963; the product, plus forty thousand (40,000) square feet. Maximum floor area can be expressed by the following site capacity formula [SR]: FA = [(ZLA—40,000) x 0.5963] + 40,000 J. Building coverage. In the GI District, the maximum building coverage [SR] for a zoning lot shall be calculated as follows: Building coverage (BC) in square feet shall equal the area of a zoning lot (ZLA) in square feet minus forty thousand (40,000) square feet; the difference times 0.4982; the product, plus twenty-eight thousand (28,000) square feet. Maximum building coverage can be expressed by the following site capacity formula [SR]: BC = [(ZLA—40,000) x 0.4982] + 28,000

(Ord. No. G66-94, § 1, 1994; Ord. No. G45-92, § 2, 1992; Code 1976, § 19.40.335)

Ask a question about Elgin law

Corpus searches the Elgin sections it holds and shows the ones that match, with their citations. Free, no sign-in.