4-8-10-5. - SPRAYING AND COATING PROCESSES.

This Section contains regulations for particulate coatings; processes involving application of metallic coatings; oil-base and other paints; catalyzed coatings; emulsion coatings; glass or mineral fiber; aerosols; lithographic and other inks; mastic, asphalt and like material when such material is applied or used regularly at a given site as in manufacturing or servicing industries. (A) Emission Limitations. Criteria in this subsection apply to plan examination. They are not intended to cover processes in which noxious, odorous, explosive or toxic materials are to be used. In such processes the design criteria for emission control provisions will be subject to approval by the Director. Approval will be based on the nature and quantity of the material used and the following sources of information: American Public Health Service; American Conference of Governmental Industrial Hygienists; Dangerous Properties of Industrial Materials, 2nd Edition; The manufacture of the materials used in the process; and Other agencies or authorities of recognized standing or experience. Approval by the Director of processes in which noxious, odorous, explosive or toxic materials are to be used shall not relieve any person from meeting the requirements of Section 4-8-10-2 of this Chapter. 1. Particulate Emission: Particulate shall include liquids, condensable at sixty degrees (60º) F., exclusive of uncombined water. Particulate emission shall not exceed ten-hundredths (0.10) grains per standard cubic foot of exhaust gas, calculated on the basis of minimum velocity requirements hereinafter established. 2. Combustible Emission: The maximum concentration of combustible gases shall not exceed ten percent (10%) of the lower explosion limit for the gas mixture. (Refer to Appendix C of NFPA 86A, Ovens and Furnace.) (B) Emission Control Equipment; Function, Basic Design Criteria. Emission control equipment shall be provided for each spraying and coating process whenever the amount and type of material used is such as to constitute an air pollution problem or the amount used is in excess of one gallon of volatile materials in any twenty four (24) hour period. 1. It shall be the principal function of the emission control equipment to: a. Capture in a moving airstream the airborne process materials which are not consumed in the process, and provide for partial removal of the air contaminants from the airstream prior to its discharge to the outdoor atmosphere. b. Dilute the volatile materials to safe, unobjectionable levels. Typical emission control equipment shall consist of dry-type air filter spray booth, water-wash air filter spray booth, downdraft spray gratings with a dry filter or water-wash air filter, and combinations of such equipment especially designed for a particular process, including travelling spray booths and similar special facilities. 2. The quantity required to capture the unconsumed airborne process materials, in the absence of any larger air requirements, shall be based upon maintaining an average airstream velocity of one hundred feet (100') per minute through the larger of the following: a. The total gross area of all entrances to the equipment which are open during normal operation; or b. The total gross area of the largest cross-section perpendicular to flow within the equipment. Deductions from the gross cross-section in computing this area will be allowed only for nonremovable building structural members. 3. Air exhausted from the process shall not be recirculated within the building. 4. For materials containing highly volatile solvents with no oil binders, as in lacquers and resins, a water-wash air filter unit shall be provided whenever five (5) gallons or more of such material is used per eight (8) hour shift at each processing installation. For processes using less than five (5) gallons of these materials per eight (8) hour shift at each processing installation, a dry-type air filter may be used. 5. For application of materials other than those in subsection (B)4 above, a water-wash air filter unit shall be provided whenever ten (10) gallons or more of material is used per eight (8) hour shift at each processing installation. For processes using less than ten (10) gallons of materials, other than those in subsection (B)4 above per eight (8) hour shift at each processing installation, dry-type air filter may be used. (C) Spray Booth Design. The ventilation of spraying and coating process areas shall comply with the following requirements: 1. All spraying areas shall be provided with positive mechanical ventilation adequate to prevent the dangerous accumulation of vapors, and to safely remove such vapors to a safe location; 2. Such mechanical ventilation shall be kept in operation at all times while the spraying operations are being conducted, and for a sufficient time thereafter to allow vapors from drying coated articles and finishing material residues to be exhausted; 3. Each process area shall have an independent exhaust duct system discharging to the ventilation requirements of this Code. Multiple-cabinet spray booths in which identical spray finishing materials are used with a combined frontal area of not more than eighteen (18) square feet, may have a common exhaust. If more than one fan serves one spray area, all fans shall be so interconnected so that one fan cannot operate without operating all interconnected fans. (D) Filter System Requirements. 1. Dry-Type Air Filter Installations. All dry-type air filter installations shall be equipped with an air pressure differential gauge for accurately indicating when filters should be replaced. The minimum allowable differential pressure shall be not less than one-fourth inch (¼") W.G. If the Director so requires, the differential gauge shall be suitably interlocked with the exhaust fan. 2. Water-Wash Type Air Filters. Water circulation systems shall be of sufficient capacity to provide a continuous, effective water-washing action at the exhaust openings of the spray booth. 3. Downdraft Spray Capturing Systems. If spraying is done in open areas of a building over a grating, the grating shall be larger than the object being sprayed, and the object being sprayed shall rest entirely within the granting boundaries. 4. Ducts and Vents. The process exhaust shall not discharge below any building openings or below the roofline of any surrounding building within a radius of one hundred feet (100') measured horizontally.

(Ord. No. 17-0-71; Ord. No. 8-O-12, (48-O-11(exh. A, § 4-8-10-5)), 1-23-2012)

Ask a question about Evanston law

Corpus searches the Evanston sections it holds and shows the ones that match, with their citations. Free, no sign-in.