7-13-7. - BUILDING SEWERS AND CONNECTIONS.
(A) No unauthorized person shall uncover, make any connections with, or opening into, use, alter, or disturb any public sewer or appurtenance thereof without first obtaining a written permit. (B) All disposal by any person into the sewer system is unlawful except those discharges in compliance with Federal standards promulgated pursuant to the Federal Act and more stringent State and local standards. (C) A building sewer permit will only be issued, and a sewer connection shall only be allowed, upon a demonstration that the downstream sewerage facilities, including sewers, pump stations and wastewater treatment facilities, have sufficient reserve capacity to adequately and efficiently handle the additional anticipated waste load. (D) Any person desiring to connect a building sewer to the public sewer shall, at his/her own cost and expense, install such building drain from the point of said connection to the public sewer to the end of the building sewer. It shall be the responsibility of a person utilizing the public sewer to maintain the building sewer connection at its juncture with the public sewer and the pipe from the juncture to the point of the building drain. Such maintenance shall include keeping said building sewer clean and free flowing, and the repair or replacement thereof in the event of broken or defective connections. Repair or replacement of the building sewer shall be to the specifications established by the plumbing code of the City and shall be inspected by the Plumbing Inspector prior to backfilling. (E) A separate and independent building sewer shall be provided for every building, except that where one (1) building stands at the rear of another on an interior lot and no private sewer is available or can be constructed, in the opinion of the Utilities Department, to the rear building through an adjoining alley, court, yard, or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one (1) building. (F) Prior to the abandonment or permanent disuse of a presently existing sewer connection(s), the owner of the property abutting or served by said sewer connection(s) shall make an application in writing for a permit to abandon said connection(s). Upon obtaining the permit, the property owner shall locate, remove and seal off any and all existing sewer connection(s) abutting or serving the property at the sewer main in a manner prescribed by the Utilities Department and restore the street and parkway surface to its preexisting condition. Prior to the closure of any excavation to facilitate the sealing of a presently existing sewer connection(s), the owner or contractor shall notify the Community and Economic Development Department, and an inspection of said sealed connection shall be conducted prior to backfilling. (G) Preexisting building sewers shall not be used in connection with newly constructed buildings unless approval is granted by the Utilities Department. At a minimum, the existing building sewer must meet the requirements of this Chapter by both examination and test. (H) The size, slope, alignment, materials of construction of a building sewer, and the methods to be used in excavating, placing of the pipe, jointing, testing, and backfilling the trench, shall all conform to the requirements of the building and plumbing codes or other applicable rules and regulations of the City. In the absence of code provisions or in amplification thereof, the materials and procedures set forth in appropriate specifications of the American Society of Testing Materials, Water Pollution Control Federation Manual of Practice No. 9, and standard specifications for water and sewer main construction in Illinois, shall apply. (I) The connection of the building sewer into the public sewer shall conform to the requirements of the building and plumbing code, the MWRDGC Sewer Permit Ordinance, or other applicable rules and regulations of the City, or the procedures set forth in appropriate specifications of the American Society of Testing Materials, Water Pollution Control Federation Manual of Practice No. 9, and standard specifications for water and sewer main construction in Illinois. All such connections shall be made gastight and watertight. Any deviation from the prescribed procedure and materials must be approved in writing by the Utilities Department before installation. (J) The applicant for the building sewer permit shall notify the Director of Community and Economic Development when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the Director of Community and Economic Development or his/her representative. (K) All excavations for building sewer installation and repairs shall be adequately guarded with barricades and warning lights so as to protect the public from hazard. Streets, sidewalks, parkways, and other public property disturbed in the course of the work shall be promptly restored in a manner satisfactory to the City.
(Ord. No. 57-O-10, § 2, 10-11-2010; Ord. No. 8-O-12, (50-O-11(exh. B, § 7-13-7)), 1-23-2012)
Ask a question about Evanston law
Corpus searches the Evanston sections it holds and shows the ones that match, with their citations. Free, no sign-in.