§ 8-2A-4 — CONSTRUCTION SPECIFICATIONS; SERVICE LINES; WATER METERS:

Municipal Code of Naperville, Illinois (Supp. No. 101: codified through Ordinance No. 26-049, adopted May 19, 2026) · Naperville Municipal Code § 8-2A-4

Corpus is an independent public-information project, not the official City of Naperville website. Stable reference: corpuslaw.us/code/b3fa8fad-a2fa-4ed0-9688-5dbef120d11d

8-2A-4: - CONSTRUCTION SPECIFICATIONS; SERVICE LINES; WATER METERS:

1. Construction: The following regulations shall govern the construction and repairs of all water lines. Construction and repair of all Naperville-owned water structures and appurtenances shall conform to the current Naperville Standard Specifications. This shall include all areas served by the Naperville distribution system in both DuPage and Will Counties. 2. Installation: Installation of the curbstop/box, copper service line and corporation stop shall be made by a licensed plumber who has an approved construction permit for main extension and service lines with engineering plans that have been approved by the Department of Public Utilities and the City Engineer. 2.1. No service line shall be less than one-inch inside diameter. All services of two-inch inside diameter or under shall be copper pipe of the quality commonly known as "Type K". All services required to be three-inch or greater inside diameter shall be Class 52 ductile iron pipe, cement lined. 2.2. Service Lines and Taps: 2.2.1. No tap shall be made within eighteen (18) inches of hub on water main. The direct tap size shall be a minimum of one inch. When greater than one inch, the tap shall be made in accordance with the Naperville Standard Water 2. 2.2.2. The line of the service pipe shall be approximately at right angles with the sidewalk, and the curbstop shall be located directly opposite the tap in the main. Where the sidewalk covers the entire parkway, the curbstop must be installed on the service pipe not less than one foot inside the edge of the curb. 2.2.3. Care should be taken in backfilling at the service connection area to give adequate support to the corporation connection and to prevent future settling. 2.2.4. Should it become necessary to repair new or existing service lines, the provisions of this Article shall apply. It is acceptable to repair an existing service line with a new pipe of the same diameter but the material must conform to the provisions of this Article. No lead service pipes or flare connections will be allowed. Repairs shall be made with appropriate compression fittings. 2.3. Each and every water service pipe shall have curbstop/box installed in accordance with Naperville Standard Water 2 up to, but not including, three (3) inches in diameter. When service lines of three (3) inches or greater are used, a gate valve of an approved pattern shall be provided. Each and every curbstop must be protected with a curbstop box in accordance with Naperville Standard Water 2. Such curbstop box in all cases must be placed plumb and square over said curbstop and a solid support block shall be placed under the curbstop to give the curbstop adequate support. 2.4. No more than one building shall be supplied from one service pipe. Whenever possible, the service pipe shall enter the building in a direct line with the curb stop and tap. Said pipe shall be provided with a valve before and after the water meter, not less than one foot inside of the wall or above the foundation floor. Such shutoffs shall be known as main building shutoff valves. The property owner shall be responsible for the maintenance, repair or replacement of the main shutoff valves. 3. Meters: Water meters shall be set in the following manner: 3.1. Inside of the building, an individual meter for each occupied dwelling shall be placed on the service pipe where the service pipe enters the building or is divided into the individual units. Each individual meter shall have an individual outside shutoff valve/box. Meters shall be readily accessible and protected from frost and shall be placed in a location which will allow the Department of Public Utilities to gain access to the meter for maintenance and repairs without having to crawl under or climb over obstacles. The water meter may not be located in the crawl space unless authorized by the Department of Public Utilities. 3.2. Said meters shall be provided with two (2) shutoff valves, one on the supply and one on the house side of the meter. It shall be the property owner's responsibility to maintain, repair or replace shutoff valves. Copperhorns/meter setters shall also be the responsibility of the property owner. 3.3. Outside meter pits shall be prohibited unless authorized in writing by the Director of Public Utilities. When allowed, all said meter vaults must be poured in place and be watertight. An outside reader receptacle must be installed on a pole outside of the vault for the purpose of reading the water meter. 3.4. The property owner or occupant must notify the Department of Public Utilities of any problem with a water meter which may require repair. 3.5. All repairs or replacement costs, other than normal maintenance of the water meter, including, without limitation, freezing, hot water damage or damages caused by unknown persons, shall be the responsibility of the property owner. The Department of Public Utilities shall furnish the water meters. Water meters greater than one inch in size shall be installed by a person determined by the City to be a qualified plumber. The plumber shall notify the Department of Public Utilities after required repairs are complete. 3.6. Plumbers are prohibited from turning the water on to any service pipe except upon the order or permission of the Department of Public Utilities. Permission shall be given for a water turn on after a meter has been installed and the work and material used have been approved and inspected by the Department of Community Development inspector who shall issue a certificate of approval to that effect. 3.7. All nonresidential buildings or structures shall include electrical conduit with pull wire to readily facilitate the future installation of wiring for outside reader receptacles. All said conduit shall be three-fourths-inch in diameter. Conduit placement to facilitate the outside reader must be within five (5) feet of the electric meter. 3.8. All lawn sprinkling systems or other water services shall be plumbed and connected into the water supply system by a separate meter prior to the domestic meter. Subtractive meters will not be allowed. Wastewater charges shall be paid on all water metered unless preauthorized by the Director of Public Utilities. Appropriate cross connection control will be required as set forth in Section 8-2A-2 of this Article. 4. Construction Cost: 4.1. The entire cost of construction of a water service, including materials used, shall be paid by the applicant. The water service from the curb stop box (located at the property line) into the property shall be maintained at the sole expense of the property owner. 4.2. In case of a leak in that portion of the water service to be maintained by the property owner, the City or a certified plumber will shut off the water until the repair is properly made. The plumber shall notify the City at the time of the shutoff and after the repairs are completed.

(Ord. 92-234, 12-15-1992)

Ask a question about Naperville law

Corpus searches the Naperville sections it holds and shows the ones that match, with their citations. Free, no sign-in.