§ 6-15-4 — SMALL WIND ENERGY SYSTEMS:
Municipal Code of Naperville, Illinois (Supp. No. 101: codified through Ordinance No. 26-049, adopted May 19, 2026) · Naperville Municipal Code § 6-15-4
Corpus is an independent public-information project, not the official City of Naperville website. Stable reference: corpuslaw.us/code/fbd8ecda-7df3-40f3-af28-f2f91865acc7
6-15-4: - SMALL WIND ENERGY SYSTEMS:
1. Authorization of Use: 1.1. Roof-Mounted Small Wind Energy System: 1.1.1. Permitted Use: Roof-mounted small wind energy systems may be authorized administratively in all Business Districts listed in Chapter 7 and Industrial Districts listed in Chapter 8 in accordance with the requirements of this Title and subject to approval by the Director of Public Utilities and the Director of Transportation, Engineering and Development, or their designees. 1.1.2. Conditional Use: Roof-mounted small wind energy systems may be authorized as a conditional use in any Residence District listed in Chapter 6 in accordance with the procedures established in Section 6-3-8 (Conditional Use) of this Title and the provisions of Section 6-15-6 of this Chapter. 1.2. Ground-Mounted Small Wind Energy System: 1.2.1. Permitted Use: Ground-mounted small wind energy systems may be authorized administratively in the I (Industrial), ORI (Office, Research and Light Industrial), RD (Research and Development) and BP (Business Park) Districts up to a height of one hundred (100) feet in accordance with the requirements of this Chapter and subject to approval by the Director of Public Utilities and the Director of Transportation, Engineering and Development, or their designees. 1.2.2. Conditional Use: 1.2.2.1. A ground-mounted small wind energy system may be authorized as a conditional use in any Residence District listed in Chapter 6 or in any Business District listed in Chapter 7 except the BP (Business Park) District in accordance with the procedures established in Section 6-3-8 (Conditional Use) of this Title and the provisions of Section 6-15-6 of this Chapter. 1.2.2.2. A ground-mounted small wind energy system may be authorized as a conditional use in the I (Industrial), ORI (Office, Research and Light Industrial), RD (Research and Development) and BP (Business Park) Districts when greater than one hundred (100) feet in height. 1.3. Number: Only one (1) ground mounted small wind energy system or one (1) roof-mounted small wind energy system shall be permitted per lot in accordance with the provisions of this Chapter. 2. Height: 2.1. Roof-Mounted Small Wind Energy System: The total height of a roof-mounted small wind energy system shall not exceed ten (10) feet above the peak roof height or ten (10) feet above the maximum permitted height of the zoning district, whichever is less. 2.2. Ground-Mounted Small Wind Energy System: 2.2.1. In all Business Districts listed in Chapter 7, except BP (Business Park), and for any institutional, utility or non-residential use in any Residence District listed in Chapter 7, ground-mounted small wind energy systems shall be limited to a maximum total system height of sixty (60) feet. 2.2.2. In the I (Industrial), ORI (Office, Research and Light Industrial), RD (Research and Development) and BP (Business Park) Districts, ground-mounted small wind energy systems shall be limited to a maximum total system height of one hundred fifty (150) feet. 2.2.3. In all zoning districts, the minimum clearance between the lowest tip of the rotor or blade and the ground shall be fifteen (15) feet. 2.2.4. Any small wind energy system that exceeds the height limitations defined in this Section shall be required to obtain approval of a zoning variance in accordance with Section 6-3-5 (Variances) of this Title. 2.3. Roof-mounted and ground-mounted small wind energy systems accessory to a residential use in a Residence District listed in Chapter 6 shall have a maximum height limitation as determined through the conditional process in accordance with the procedures established in Section 6-3-8 (Conditional Uses) of this Title and the standards provided in Section 6-15-6.3 of this Chapter. 3. Location: 3.1. Roof-Mounted Small Wind Energy Systems: 3.1.1. Roof-mounted small wind energy systems shall be affixed to the roof deck of a flat roof or to the ridge or slope of a pitched roof and may not be affixed to the parapet or chimney of any structure. 3.1.2. Such systems must be set back a minimum of five (5) feet from the edge or eave of the roof. 3.2. Ground-Mounted Small Wind Energy Systems: 3.2.1. Ground-mounted small wind energy systems, including all appurtenances and anchoring equipment, shall not be located within the required front yard or corner side yard or in any utility, water, sewer, or other type of public easement. 3.2.2. Ground-mounted small wind energy systems, including all appurtenances and anchoring equipment, shall be set back a distance equal to 1.1 times the system height, from the base to all property lines, third party transmission lines, ground-mounted small wind energy systems, overhead electric distribution systems and communication towers. 4. Noise: Sound levels for any small wind energy system shall not exceed the maximum decibels established in Chapter 14 (Performance Standards) of this Title. The City may, at its discretion, require a professional sound measurement by a third party expert at the expense of the property owner, to confirm performance of the wind energy system, in accordance with the performance standards, as measured from the ground level at the nearest property line. 5. Color: Small wind energy systems may remain finished in the color originally applied by the manufacturer, unless otherwise authorized by the building permit. Finishes shall be non-reflective, neutral and monochromatic in color and shall minimize visual disruption to the surrounding area. Ground equipment, such as cabinets and associated facilities, shall be factory finished to match or complement the color of other structures on the lot. 6. Unauthorized Access: Ground-mounted small wind energy systems and all components thereof shall be protected against unauthorized access by the public. No climbing ladder, foot pegs or rungs shall be permanently attached below a height of twelve (12) feet above grade.
(Ord. No. 10-159, § 1, 12-21-2010)
Ask a question about Naperville law
Corpus searches the Naperville sections it holds and shows the ones that match, with their citations. Free, no sign-in.