Sec. 14-80. - Fire protection.
(a) IFC 507.3.1, fire-flow method. The approved fire-flow method shall be determined by utilizing IFC Appendix B fire-flow requirements for buildings. (b) IFC 507.3.2, fire-flow design for combined fire sprinkler and fire hydrant system. (1) This subsection (b) shall apply to sites and facilities that utilize on-site water storage that feeds both the fire sprinkler system and the fire hydrants, when the fire hydrants are fed from the sprinkler system, or when the fire hydrants and fire sprinkler system utilize a common water service to the water purveyor's system. (2) A submittal to the fire official of the available site fire flow when the fire sprinkler system is fully operational. If the fire flow available is less than as required per IFC 507.3.1 arrangements shall be made to provide the minimum flow or at a rate determined by the fire official. Otherwise, the fire official shall evaluate the department's standard operating procedures and building size up to determine if the fire flow available is to be considered sufficient. (c) Section 903.1.2, sprinkler system backflow replacement. Whenever an existing fire sprinkler system's backflow prevention device is added or replaced with a different make, model, etc., the system shall be recalculated to ensure that the design density is satisfied. Should the design density be inadequate, the automatic sprinkler system shall be redesigned as needed to be in compliance with the required design density. Additionally, systems that require reconfiguration of the riser assembly to accommodate the new backflow device shall also include a means to forward flush the fire sprinkler backflow device, if one is not already provided. That forward flush shall be of a type that does not require the system to be taken offline or disassembled to complete the testing. (1) Sprinkler design safety factor. Fire sprinkler systems, per NFPA 13, NFPA 13R shall be designed with a minimum safety factor of five psi provided between the available water supply and the system flow and pressure demand and shall include hose stream allowances required by NFPA 13, and 13R. (2) Inspection, testing and maintenance records. In addition to the requirements described in section 901.6.3 of the 2021 International Fire Code, all inspection, testing, and maintenance records shall be submitted to the fire department in an approved manner. (3) Automatic sprinkler systems; new buildings. Approved automatic fire sprinkler systems, installed in accordance with NFPA 13 and/or NFPA 13R, shall be installed in all new commercial buildings and structures regardless of the materials used in construction and/or use group classification (as defined in the International Building Code). Small buildings under 1,000 square feet can petition to the fire official for a fire sprinkler exemption. The petition shall clearly address the following factors building size, occupancy use, occupancy load, construction type, separation from other structures, utilities, and lot lines. Sprinkler systems shall be equipped with electronically monitored water flow separation zone valves and drains that will provide a means to control the systems for each commercial unit and/or floor level in the case of a multi-story residential or commercial structure. These zone valves will not eliminate the requirement for the main riser flow switch. (4) Fire protection systems; existing buildings. Requirements for existing buildings that are added to, remodeled, repaired, altered, or have a change in occupancy shall be determined per the International Existing Building Code, 2021 edition, or as required by adopted codes. (5) Smoke alarms existing buildings. Where the International Property Maintenance Code allows battery-only smoke alarms, all new single- and multiple-station battery-only smoke alarms shall have a self-contained, non-removable, long-term battery in accordance with 425 ILCS 60/1. (6) Fire department connections and hydrants. a. Fire department connections. 1. Location. Fire department connections shall be located and be visible from a street front or in a location approved by the fire department. Such connections shall be located so that immediate access can be made by the fire department and within 150 feet of a fire hydrant. Fire department connections shall not be obstructed by fences, bushes, trees, walls, or any other similar object. 2. Type. Fire department connections shall be a four-inch Storz with a 30-degree elbow. b. Private fire hydrant design. 1. Fire hydrants shall match the hydrants generally installed in the village's water system and shall be furnished by a manufacturer considered standard by the village as specified in the supplement to the subdivision regulations. 2. Only breakaway hydrants shall be used. 3. Each fire hydrant shall be the compression type with a 5¼-inch minimum size main valve assembly, O-ring seals, two 2½-inch hose nozzles and a 4½-inch pumper nozzle with National Standard threads, a National Standard operation nut, and a breakaway ground level flange, and conforming to the latest revised requirements of AWWA Specification C 502. 4. Each hydrant shall be provided with a six-inch auxiliary gate valve and a two-foot length of six-inch pipe between the hydrant and valve. (i) Two three-fourths-inch threaded steel rods with hex nuts shall be installed to tie the auxiliary gate valve to the water main and connecting tee. (ii) Auxiliary valves shall be provided with valve boxes with covers marked "water." (7) Sprinkler system monitoring and alarms. a. Alarm, supervisory, and trouble signals shall be distinctly different and shall be automatically transmitted to the fire department remote receiving station as defined in NFPA 72. b. Strobe lights at the sprinkler connection. There shall be an electronic audiovisual device located on the exterior wall above all new fire department sprinkler and/or standpipe connections which shall activate when water is flowing. The device shall be specified for outdoor use (weatherproof) and must be visible from the street or driveway. (8) Standpipe systems. a. In buildings exceeding 50,000 square feet in area per story, Class I automatic wet or manual wet standpipes shall be provided where any portion of the building's interior area is more than 150 feet of travel, vertically and horizontally, from the nearest point of fire department vehicle access. b. Where the most remote portion of a floor or story is more than 150 feet from a hose connection, the fire prevention official is authorized to require that additional hose connections be provided in approved locations. (9) Fire alarm and detection systems. All required fire alarm systems shall transmit trouble, supervisory, and fire signals directly to the fire department remote receiving station in accordance with NFPA 72, only equipment certified and approved by the remote receiving station, and/or its designated proprietor may be installed. a. Commercial cooking suppression systems. All new, upgraded, or modified existing commercial kitchen hood equipment protected by an automatic fire suppression system as required by section 904 of the International Fire Code (IFC) shall have the system monitored electronically by an approved fire alarm installed per the requirements of NFPA 72. The fire panel shall be a direct tie to the fire department per the requirements of this subsection (9). Audiovisual devices shall be installed; one in the kitchen area, and, if applicable, in the dining areas. b. Clothes dryer exhaust. 1. Property/business owners of commercial properties shall inspect clothes dryer exhaust piping and duct systems annually, or when an impairment is suspected. If during the inspection, it is found that an accumulation of lint or debris is present, the exhaust piping or duct systems shall be cleaned or replaced. Records of inspection and or cleaning shall be maintained by the property/business owner and provided to the village fire department in an approved format on request. 2. Property owner/association of multifamily occupancies shall have the clothes dryer common vent stacks inspected annually or when an impairment is suspected. If during the inspection, it is found that an accumulation of lint or debris is present, the common vent stack shall be cleaned. Records of inspection and or cleaning shall be maintained by the property owner/association and provided to the village fire department in an approved format upon request. c. Dedicated sprinkler riser room. Dedicated sprinkler riser rooms shall be provided for all new strip retail centers, speculative warehouses, or any other multifamily or multi-tenant buildings. These rooms shall follow the specifications of the IFC 901.4.7. In addition, such rooms shall: 1. Be located on the ground floor in an approved location directly accessible from the exterior. The door shall be a minimum of 36 inches wide and labeled as the sprinkler or sprinkler/alarm. 2. Have a paved surface that is the width of the door or at least a minimum of a 36 inches wide to provide access to the door. 3. Be of a size that will allow a minimum of 36 inches clear space at the front and 18 inches on the remaining sides of all risers, 36-inch clearance in front of the fire alarm panels and around all portions of the fire pump assembly. Permanent floor markings shall be provided to define said clear space. 4. Be provided with lighting hard-wired to the building electrical system, emergency lighting, and hardwired permanent heat. 5. Be monitored by a low-temperature alarm tied to the fire alarm system. 6. Have wall construction matching the demising wall construction for the separation of tenant spaces. (10) Fire department access to secured buildings. a. A Knox® box, as approved by the fire department, shall be installed on all buildings with a required fire alarm system, and on any building where immediate access by the fire department is deemed necessary. The locations shall be approved by the fire department. The boxes shall contain keys, properly identified, which allow access to all portions of the building. A three-foot-wide clear and unobstructed path shall be provided and maintained to access the Knox® box. b. New apartment and condominium buildings shall provide an appropriately sized Knox® box in an approved location inside the building, in which the owner/resident can place a key in for emergency access to their unit. This Knox® box is in addition to any required Knox® box on the exterior of the building. (11) Special emergency electrical wiring requirements. Structures 35 feet in height and/or four stories and higher shall be provided with non-energized wiring to provide emergency power for firefighting and other fire department use. Non-energized interconnected outlets shall be located in each stairwell and at each floor level, including the ground level. a. Provide a National Electrical Manufacturer's Association approved red exterior grade male twist lock receptacle, compatible with the fire department cords and generators, and a weathertight snap cover adjacent to the fire department siamese connection, on the outside of the building. The location shall be approved by the fire department and not obstruct access to the siamese connection. b. Provide a National Electrical Manufacturer's Association approved red exterior grade female twist lock receptacle, compatible with the fire department cords and generators, and with weathertight cover in each stairwell, at each floor level. c. If the required receptacles are not flush-mounted, waterproof boxes must be provided. Structures up to 100 feet in height shall be wired with a minimum of No. 8 gauge wire in three-quarter-inch conduit. Structures over 100 feet in height shall be wired with a minimum of No. 6 gauge wire in one-inch conduit. The conduit must be properly grounded to the neutral wire. d. Conduit concealed within a wall can be thin wall; heavy wall conduit must be used if the conduit is exposed. e. Wiring shall be three pole, three-wired grounded circuit conforming to the National Electrical Code. f. The plug shall be a standard 20 amp twist lock, L520P (male) and L520C (female). (12) Emergency responder communication coverage system evaluation. IFC 510.1.1, new education (E), institutional (I), or high hazard (H) occupancy, any building that is of four stories or more, any building that has a story below grade, and any building that has a footprint of 250,000 square feet shall provide an evaluation from a qualified emergency responder communication coverage designer on whether the building shall/may require an emergency responder communication coverage (ERCC) system. The evaluation shall provide information on the feasibility of the site and if an ERCC system is necessary. The results of said evaluation should be reflected in the primary construction documents.
(Code 1976, § 7-40; Ord. No. O-61-05, § 1, 3-21-2005; Ord. No. O-210-06, § 4, 12-4-2006; Ord. No. O-200-07, §§ 1, 2, 12-3-2007; Ord. No. O-25-08, § 2, 2-19-2008; Ord. No. O-127-09, § 3, 11-16-2009; Ord. No. O-23-10, § 1, 3-15-2010; Ord. No. O-70-13, § 2, 6-10-2013; Ord. No. O-94-18, 8-13-2018, eff. 1-1-2019; Ord. No. O-63-23, 5-15-2023; Ord. No. O-112-24, exh. A(7-40), 12-2-2024)
Ask a question about Palatine law
Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.