§ 22-92 — Lighting
Code of Ordinances of the Village of Palatine, Illinois (Codified through Ordinance No. O-113-26, enacted October 12, 2026. (Supp. No. 2, Update 2)) · Palatine Code of Ordinances § 22-92
Corpus is an independent public-information project, not the official City of Palatine website. Stable reference: corpuslaw.us/code/8621d1be-0d91-4f9b-b871-e66eec9fc94f
Sec. 22-92. - Lighting.
(a) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: ..... Floodlight means a luminaire designed so that at least 90 percent of the emitted light is within an angle of 30 degrees to the centerline of the light beam. Foot lambert means the brightness of a perfectly diffusing surface uniformly emitting or reflecting one lumen per square foot of surface. Footcandle means the amount of illumination provided by a light source of one international candle at a distance of one foot from the light source. International candle or candle power means the unit of luminous intensity as established by standard light sources as maintained by the U.S. Bureau of Standards. This is more commonly called "one candle power." Lumen means that quantity of luminous energy included in one steradian unit solid angle from a uniform point source of one candle power. The term "lumen" also means the luminous flux intercepted by a surface of one square foot, all points of which are one foot from a uniform point source of one candle power. Luminaire means a device or fixture containing a light source and means for directing and controlling the distribution of light emitted therefrom. (b) Regulations of intensity of light. It is unlawful for any person, association or other legal entity owning, occupying or controlling any property within the village to exceed the following light intensity regulations: ..... (1) No lighting source shall cause more than one-tenth (0.1) footcandle of illumination to fall on adjoining R1, R1A, R1B, R1C and R2 residentially zoned property and any property zoned P or PUD which is improved with one or more single-family detached dwellings. ..... (2) No lighting source shall cause more than two-tenths (0.2) footcandle of illumination to fall on adjoining R3 or R3A residential property and any property zoned P or PUD which is improved multifamily property. ..... (3) No lighting source shall cause more than two footcandles of illumination to fall on any adjoining commercially zoned property and any property zoned P or PUD which is improved commercial property. ..... (4) No lighting source shall cause more than five footcandles of illumination to fall on any public way in commercially zoned property. ..... (c) Regulations on glare. Regulations on glare shall be as follows: ..... (1) No floodlight shall be mounted higher than 25 feet above the ground nor shall any part of any floodlight's beam strike the ground at any angle of more than 45 degrees from vertical. ..... (2) No light source shall present a surface brightness when viewed between horizontal and an angle of 45 degrees above horizontal from adjoining property in accordance with the following: ..... a. 750-foot lamberts from R1, R1A, R1B, R1C and R2 zoned property. ..... b. 1,500-foot lamberts from R3 and R3A zoned property. ..... c. 2,200-foot lamberts from any commercially zoned property. ..... d. 10,000-foot lamberts from any public way. ..... (d) Standards of measurement. ..... (1) Light intensity shall be measured in footcandles with a direct reading portable low range light meter having a range of zero to 20 footcandles. Values set forth in this section are maximum values measured at 90 degrees to the incidence of light from the source. ..... (2) Measurement methods and techniques shall be those recommended by the Illuminating Engineering Society in their standard methods for measuring and reporting horizontal footcandles. ..... (3) Brightness measurement based on foot lambert must be governed by the definition of the foot lambert and lumen. Calculated values for source brightness may be obtained by using comparable measurement techniques. Calculations shall be in accordance with the following: ..... a. Spherical bare sources (incandescent lamps). The brightness shall be calculated as total lumens divided by one-tenth the square of the diameter of the source measured in inches. ..... b. Cylindrical bare sources (fluorescent lamps). The brightness shall be calculated as total lumens divided by 1/50 the product of length and diameter of the source in inches. ..... c. Floodlight sources. The brightness of floodlight sources shall be calculated as the eight-tenths of the total lumens divided by the area of the face of the floodlight in square feet. ..... 1. If the light source is mounted in a diffuse luminaire, seven-tenths of the values in subsection (d)(3)c of this section shall be used. ..... 2. The values of lumens to be used shall be based on the following efficiencies: ..... Incandescent Filament Lamps | Gaseous Discharge Lamps 25 watt—250 lumens | 40 watts—1,200 lumens 40 watt—500 lumens | 100 watts—3,000 lumens 60 watt—800 lumens | 250 watts—11,000 lumens 100 watt—1,600 lumens | 400 watts—25,000 lumens 200 watt—3,300 lumens | 1,000 watts—65,000 lumens 300 watt—5,000 lumens 500 watt—9,000 lumens 1,000 watt—20,000 lumens (e) Enforcement. Any existing lighting condition determined by the environmental health director to be in violation of any of the provisions of this section shall, within the time determined on a written notice to the violator, be corrected. Service of notice may be made by personal service, publication in a local newspaper generally circulated within the village, conspicuous posting on the premises where the violation occurs or by U.S. mail. ..... (f) Hearing of variations. Where practical difficulties or particular hardships, not created by any person having interest in the property, prevents carrying out the strict letter of any of the provisions of this section, the environmental health division, on petition, may determine and vary the requirements of this section to the extent that they are still in harmony with its general purpose and intent. However, any such variation shall be made by the division as specified only after a hearing before the division, of which hearing there shall be notice of time and place of the hearing given by publication not less than 15 days nor more than 30 days before said hearing, and also by United States mail addressed to the persons or entity seeking a variation from the requirements of this section and the owners of any adjacent property. ..... (g) Violations declared a nuisance. The failure of persons owning or occupying the property to abate any lighting violations, as stated in this section, is declared a public nuisance and shall be subject to the abatement provisions of article VII, division 3, and the penalty provisions of section 22-264. .....
(Code 1976, §§ 12-310—12-316; Ord. No. O-109-89, § 1(12-300—12-306), 8-14-1989)
Ask a question about Palatine law
Corpus searches the Palatine sections it holds and shows the ones that match, with their citations. Free, no sign-in.
