Sec. 105-214. - Adoption of technical codes.
The following documents are hereby adopted as and shall be known as the elevator safety code, establishing minimum requirements, with due regard to function, for the design, operation, inspection, and maintenance of elevators within the city; and each and all of the regulations, provisions, penalties, conditions and terms of the documents set forth below are hereby referred to, adopted, and made a part hereof, as if fully set out in this Code, with any additions, insertions, deletions and changes prescribed in this chapter, said documents being the following: (1) American Society of Mechanical Engineers (ASME). (a) Safety Code for Elevators and Escalators (ASME A17.1-2019/CSA B44-2019) and Performance-Based Safety Code for Elevators and Escalators (ASME A17.7-2007 reaffirmed 2017/CSA B44.7-07 reaffirmed 2017). i) Modification and Exclusion to the Safety Code for Elevators and Escalators (ASME A17.1-2019/CSA B44-2019) adopted by the Illinois Elevator Safety Review Board: 1. Modification: Witnessing of Initiating Devices for Fireman's Emergency Operation. All initiating devices for all elevators shall be tested every 5 years. The test shall be witnessed by an elevator inspector. Documentation of the results of the testing of initiating devices must be kept on site in the maintenance records. All hydraulic elevators shall have this documentation completed no later than December 31, 2023. All traction elevators shall have this documentation completed at the time of their first Category 5 test after January 1, 2023. After the initial test, subsequent tests of the elevator's initiating devices shall be conducted no later than 5 years after the date of the last test. 2. Exclusion: Specifically Excluded from Adoption is Section 8.6.4.20.1(b) Alternative Test Method for Car Safeties; ii) A conveyance may be placed out of service in two different ways: 1. To permanently remove a conveyance from service, the ASME A17.1, Section 8.11.14 procedures shall be followed: Periodic inspections and tests shall not be required when an installation is placed "out of service": (a) As defined by the authority having jurisdiction; or (b) when an installation whose power feed lines have been disconnected from the mainline disconnect switch; and i) an electric elevator, dumbwaiter, or material lift whose suspension ropes have been removed, whose car and counterweight rest at the bottom of the hoistway, and whose hoistway doors have been permanently barricaded or sealed in the closed position on the hoistway side; ii) a hydraulic elevator, dumbwaiter, or material lift whose car rests at the bottom of the hoistway; when provided with suspension ropes and counterweight, the suspension ropes have been removed and the counterweight rests at the bottom of the hoistway; whose pressure piping has been disassembled and a section removed from the premises and whose hoistway doors are permanently barricaded or sealed in the closed position on the hoistway side; or iii) an escalator or moving walk whose entrances have been permanently barricaded. The identified conveyance has been permanently removed from service and ASME A17.1 procedures for permanent removal have been followed. Or, 2. "Temporarily dormant" — means an elevator, dumbwaiter or escalator: (a) With a power supply that has been disconnected by removing fuses and placing a padlock on the mainline disconnect switch in the "off'' position. (b) with a car that is parked and hoistway doors that are in the closed and latched position; (c) with a wire seal on the mainline disconnect switch installed by a licensed elevator inspector; (d) that shall not be used again until it has been put in safe running order and is in condition for use; (e) requiring annual inspections for the duration of the temporarily dormant status by a licensed elevator inspector; (f) that has a "temporarily dormant" status that is renewable on an annual basis, not to exceed a 5-year period; (g) requiring the inspector to file a report with the Administrator describing the current conditions; and (h) with a wire seal and padlock that shall not be removed for any purpose without permission from the elevator inspector. (b) Safety Code for Existing Elevators and Escalators (ASME A17.3-2005); (c) Safety Standard for Platform Lifts and Stairway Chairlifts (ASME A18.1-2017); (d) Standard for the Qualification of Elevator Inspectors (ASME QEI-1-2018). (2) American Society of Civil Engineers (ASCE). Automated People Mover Standards (ANSI/ASCE/T&DI 21-13).
(Ord. No. 2019-60-O, Att., 3-18-2019; Ord. No. 2022-165-O, 8-15-2022)
Ask a question about Rockford law
Corpus searches the Rockford sections it holds and shows the ones that match, with their citations. Free, no sign-in.