For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 105-222 — Visitability features

Code of Ordinances of the City of Rockford, Illinois (Supp. No. 18: codified through Ordinance No. 2024-245-O, enacted December 2, 2024) · Rockford Code of Ordinances § 105-222

Corpus is an independent public-information project, not the official City of Rockford website. Stable reference: corpuslaw.us/code/bcccad67-806f-41c2-8a58-e0a58cb6c2bb

Sec. 105-222. - Visitability features.

(a) No step entrance. There shall be at least one entrance (front, side, rear, or through the garage) which has no steps and is served by walks and/or ramps meeting the specifications of law and ordinance. (b) Visitable route. The required no step entrance shall be accessed via a visitable route that shall meet the following criteria: (1) Grade. Sidewalks and ramps that are part of a visitable route shall have the maximum slope and rise listed below: a. Ramp type 1: a slope of between 1:8 and 1:10 for a maximum rise of three inches. b. Ramp type 2: a slope between 1:10 and 1:12 for a maximum of rise of six inches. c. Ramp type 3: a slope of 1:12 for a maximum rise of 30 inches. A landing shall be located at the top and bottom of any rise of 30 inches. (2) Width. The visitable route shall have a minimum width of 36 inches. (3) Landings. Landings in a visitable route shall be not less than 36 inches by 36 inches in size. Alternate methods to the slope and rise requirements of this section, may be approved by the construction and development services division to achieve the requirements of this section. (c) Doors/openings. All doors or openings (with the exception of closet and pantry doors) shall have a minimum net clear width of 32 inches. (d) Bathrooms. At least one-half bath shall be required upon the same level as the no step entrance. Each bathroom or other room, upon the same level as the no step entrance, which contains a toilet, bathtub, shower stall, or shower seat, shall have reinforcing in the walls to allow for future installation of grab bars around those fixtures. (e) Corridors. Corridors shall be at least 36 inches in width. (f) Environmental controls. Wall electrical outlets, light switches, thermostats and other control devices shall be mounted between 15 inches and 48 inches above the finished floor.

(Ord. No. 2007-37-O, § 6-103, 2-20-2007; Ord. No. 2008-093-O, § 105-222, 5-15-2008)

Ask a question about Rockford law

Corpus searches the Rockford sections it holds and shows the ones that match, with their citations. Free, no sign-in.