§ 17.16.060 — Uniform standards for sealing an unsafe building
Code of Ordinances, City of Bloomington, Indiana (Supp. No. 51, Update 1: codified through Ordinance No. 2026-15, passed July 17, 2026) · Bloomington Municipal Code § 17.16.060
Corpus is an independent public-information project, not the official City of Bloomington website. Stable reference: corpuslaw.us/code/3aa69d98-3055-49ec-949d-9d1432e44adc
17.16.060 - Uniform standards for sealing an unsafe building.
Pursuant to Indiana Code §§ 36-7-9-5(a)(2) and 36-7-9-5(a)(8), this section hereby establishes a uniform standard for sealing an unsafe building against intrusion by unauthorized persons when such an order is issued by the housing and neighborhood development department or the board of public of works: (a) All openings of a building shall be closed. (b) Openings that are more than one square foot in area and located less than twenty feet above the ground or that are accessible from a part of the building such as a fire escape or other means of access shall be secured by the following means: (1) Plywood or oriented strand board, covered with a weatherproofing substance such as exterior paint or varnish, similar in color to the exterior of the building and cut to the inside dimension of the exterior of the opening, shall be placed in all openings in such a way that no portion of the plywood or oriented strand board extends outside the existing frame. (A) The plywood or oriented strand board shall be placed against any existing exterior window slide trim or a furring strip. (B) If there is no slide trim or furring strip, an equivalent block shall be installed. (C) The slide trim, furring strip or block shall be sufficient to prevent the plywood or oriented strand board from being pushed inward. (D) The plywood or oriented strand board shall be affixed to the exterior frame by use of two and three-quarters-inch or longer ring nails spaced a maximum of eight inches apart. (2) Where the inside dimension of the opening exceeds twenty-six square feet in area, additional exterior support shall be provided by placing continuous pieces of nominal two-inch by four-inch framing grade lumber on the outside of the plywood or oriented strand board in such a manner that every carriage bolt used in the opening passes through and joins such a piece of nominal two-inch by four-inch lumber, the plywood or oriented strand board and the interior brace. (A) The round head of the bolt shall be on the outside of such pieces of nominal two-inch by four-inch lumber that gives exterior support. (B) The pieces of nominal two-inch by four-inch framing grade lumber shall be covered with a weatherproofing substance such as exterior paint or varnish, similar in color to the exterior of the building. (3) In case of a ground level door the following method of securing shall be used: (A) The door shall be placed in good repair including, but not limited to, closing any openings in the door, repairing hinges on the door and providing for an adequate closure to the opening; and (B) The door shall be locked by the use of not less than two hasp locks and padlocks to be located equidistant from the top and bottom casing and each other. (C) If no door exists, or if it is impractical to repair the existing door, the opening shall be secured in the manner described in this subsection, substituting, however, a piece of plywood or oriented strand board for the door. They plywood or oriented strand board shall be covered with a weatherproofing substance such as exterior paint or varnish, similar in color to the exterior of the building. (c) Any opening that is less than one square foot in area or that is both more than twenty feet above the ground and not accessible from a part of the building shall be covered so as to prevent the entry of birds, rats or other animals and shall be made weather tight. The covering shall be painted in color similar to the exterior of the building. (d) The materials used to secure the openings of a building pursuant to these standards shall meet the following specifications: (1) Plywood or oriented strand board: no less than one-half-inch exterior grade; (2) Braces: no less than nominal two-inch by four-inch framing grade lumber; and (3) Bolts: no less than three-eighths-inch carriage bolts. (e) The housing and neighborhood development department or board of public works may allow the use of other materials and methods of securing openings, including the use of existing doors, if it is shown that, as related to the particular circumstances, the objectives of these standards would be met by the use of such materials and methods.
(Ord. No. 14-23, § 1, 10-29-2014)
Ask a question about Bloomington law
Corpus searches the Bloomington sections it holds and shows the ones that match, with their citations. Free, no sign-in.
