§ 15.05.140: Installation standards for mobile and manufactured homes.

(A) New home installation or used home re-installation inside parks shall have piers and anchors installed to manufacturer’s specification and utilize “over the top” or sidewall straps, if provided from the factory on the home. If manufacturer’s specifications are not available for new installation of older homes in parks, the piers shall be installed within two feet of the end of the frame beams and a maximum of eight feet on center and on each side of a four-foot-wide or more opening in an exterior or marriage wall. Ground anchors and tiedown straps shall be installed within two feet of each end of the frame beams and a maximum of 12 feet on center and utilize “over the top” or sidewall straps, if provided from the factory on the home. Provision for diagonal ties between ground anchors and the mobile home shall be made in conjunction with each vertical tiedown. All anchoring equipment shall be installed in accordance with the equipment manufacturer’s installation instructions. In no case shall installation standards be required to exceed those provided with the home by the manufacturer. (B) Existing homes on existing lots in parks shall have ground anchors and tie-down straps within six feet of each end of frame beams and a maximum of 24 feet on center utilizing “over the top” or sidewall straps, if provided from the factory on the home. Provision for diagonal ties between ground anchors and the mobile home shall be made in conjunction with each vertical tie-down. All new anchoring equipment shall be installed in accordance with the equipment manufacturer’s installation instructions. Where homes do not have usable areas on the frame beams to attach anchors, other acceptable means shall be incorporated to provide equivalent resistance to lateral and uplift wind forces. In no case shall installation standards be required to exceed those provided with the home by the manufacturer.

( 1983 Code § 15.150.031 )

Ask a question about Evansville law

Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.