§ 15.20.020: General structural requirements.

(A) All signs shall be constructed and erected in a safe and stable manner in accordance with the provisions of this chapter applicable to their construction. Every sign installed within the City prior to the passage of the ordinance codified in this chapter, which is deemed unsafe by the Building Commissioner, shall be removed immediately on the order of the Commissioner, or shall be put in a safe condition. (B) All signs shall be constructed and erected to withstand a horizontal wind load of 30 pounds per square foot in any direction together with the dead load of the construction. The design of roof signs exceeding 25 feet in height above the roof shall be designed for a minimum wind load of 10 pounds per square foot on projected area of ends of framework. Wind load on the front and rear of a sign shall be taken as 30 pounds per square foot on the actual exposed area, but the total load assumed as acting on the front and rear faces of a sign shall not be less than that obtained by considering the horizontal projection of the front and rear as a solid surface acted upon by a wind pressure of 10 pounds per square foot, the equivalent force considered as acting at two-thirds of the height of the sign above the base. Adequate sway bracing in a horizontal place shall be provided at the foundation and across the framework at intervals to stiffen the sign in all directions. The compression members of frame and bracing systems shall have a l/r ratio not exceeding 150 pounds. All connections on roof signs and on projecting signs over 144 square feet in area shall be made by rivets or tightfitting smooth bolts in reamed holes of not less than five-eighths-inch diameter. The rivets and bolts may be estimated at 10,000 pounds per square inch shear and 20,000 pounds per square inch bearing. The threaded portion of the bolts shall not be placed in shear or bearing. Allowable stresses on structural steel shall be in accordance with the provisions hereinbefore provided. All load and reactions shall be transmitted to structural framework and walls of buildings. (C) Wood posts shall not be used for the construction of pole-supported projecting signs. Turnbuckles, connections, and the like, shall be provided with closed eyelets welded or forged. All connections between cables and turnbuckles, eye bolts, or angles shall be made with cable bent around a standard thimble of proper size, and the cable shall be properly twisted around itself by separate strands. Expansion bolts for the securing of projecting signs shall not be smaller in size than one-half inch by four inches for 12-foot by six-foot signs; one-half inch by three inches for 10-foot by five-foot signs; three-eighths inches by three inches for eight-foot by four-foot signs; and three-eighths inches by two inches for signs smaller than eight feet by four feet. Where brickwork is of poor quality or inadequately bonded, through-bolts shall be used. Crossarms, clamps, and connections on pole signs shall be made of sufficient strength and rigidity to withstand a wind load of 30 pounds per square foot on the face of the sign. (D) All signs for which a permit is required shall be erected in such a manner and with material as to remain safe and secure for a period of at least one year from the date of erection, and all bolts, cables, and other parts of the signs shall be kept painted and free from corrosion by the erector during the time. Any defect due to the fault of the erector during that period shall be repaired at the expense of the erector, but damage done by others shall be repaired by the owner. After expiration of the original maintenance permit, all damage, defects, and corrosion shall be promptly repaired by the owner on notice from the Building Department. (E) Projecting signs may extend above the coping of any building; provided, that the details of their construction and support shall be approved by the Building Commissioner. Projecting signs which are placed wholly or partially over public highways or alleys shall be erected subject to all the provisions of this section. Projecting signs which do not encroach on public property shall be subject to all the provisions of this section except those provisions governing size and extent of projection. (F) No signs of any kind shall be attached to or placed on a building in such a manner as to obstruct any fire escape or any window or door, nor shall any sign be attached in any form, shape, or manner to a fire escape. (G) All electrical work in signs shall be in accordance with the provisions of this chapter and the rules of the Department of Buildings relative to electrical wiring. In the case of each electric sign manufactured and wired without the City, but to be installed within the City, no permit for the hanging of the sign shall be issued by the Building Commissioner until a permit covering the wiring of the sign shall have first been secured by a licensed electrician who shall thereby assume all responsibility for bringing the wiring into conformity with the requirements of this chapter; nor until the wiring shall have been inspected and approved by the Electrical Inspector of the Department of Buildings.

( 1962 Code § 1347.05 ; 1982 Code § 150.076 ; 1983 Code § 15.150.076 )

Ask a question about Evansville law

Corpus searches the Evansville sections it holds and shows the ones that match, with their citations. Free, no sign-in.